Your browser doesn't support javascript.
loading
Rapid and Resilient Detection of Toxin Pore Formation Using a Lipid Bilayer Array.
Ito, Yoshihisa; Osaki, Toshihisa; Kamiya, Koki; Yamada, Tetsuya; Miki, Norihisa; Takeuchi, Shoji.
Afiliação
  • Ito Y; Artificial Cell Membrane Systems Group, Kanagawa Institute of Industrial Science and Technology, 3-2-1 Sakado, Takatsu-ku, Kawasaki, Kanagawa, 213-0012, Japan.
  • Osaki T; Center for Multidisciplinary and Design Science, School of Integrated Design Engineering, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama, Kanagawa, 223-8522, Japan.
  • Kamiya K; Artificial Cell Membrane Systems Group, Kanagawa Institute of Industrial Science and Technology, 3-2-1 Sakado, Takatsu-ku, Kawasaki, Kanagawa, 213-0012, Japan.
  • Yamada T; Institute of Industrial Science, The University of Tokyo, 4-6-1 Komaba, Meguro-ku, Tokyo, 153-8505, Japan.
  • Miki N; Artificial Cell Membrane Systems Group, Kanagawa Institute of Industrial Science and Technology, 3-2-1 Sakado, Takatsu-ku, Kawasaki, Kanagawa, 213-0012, Japan.
  • Takeuchi S; Artificial Cell Membrane Systems Group, Kanagawa Institute of Industrial Science and Technology, 3-2-1 Sakado, Takatsu-ku, Kawasaki, Kanagawa, 213-0012, Japan.
Small ; 16(49): e2005550, 2020 12.
Article em En | MEDLINE | ID: mdl-33191570
An artificial cell membrane is applied to study the pore formation mechanisms of bacterial pore-forming toxins for therapeutic applications. Electrical monitoring of ionic current across the membrane provides information on the pore formation process of toxins at the single pore level, as well as the pore characteristics such as dimensions and ionic selectivity. However, the efficiency of pore formation detection largely depends on the encounter probability of toxin to the membrane and the fragility of the membrane. This study presents a bilayer lipid membrane array that parallelizes 4 or 16 sets of sensing elements composed of pairs of a membrane and a series electrical resistor. The series resistor prevents current overflow attributed to membrane rupture, and enables current monitoring of the parallelized membranes with a single detector. The array system shortens detection time of a pore-forming protein and improves temporal stability. The current signature represents the states of pore formation and rupture at respective membranes. The developed system will help in understanding the toxic activity of pore-forming toxins.
Assuntos
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Toxinas Bacterianas / Bicamadas Lipídicas Tipo de estudo: Diagnostic_studies Idioma: En Revista: Small Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Toxinas Bacterianas / Bicamadas Lipídicas Tipo de estudo: Diagnostic_studies Idioma: En Revista: Small Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Japão