Your browser doesn't support javascript.
loading
Asymmetric susceptibility tensor imaging.
Cao, Steven; Wei, Hongjiang; Chen, Jingjia; Liu, Chunlei.
Afiliação
  • Cao S; Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, California, USA.
  • Wei H; Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, California, USA.
  • Chen J; Institute for Medical Imaging Technology, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.
  • Liu C; Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, California, USA.
Magn Reson Med ; 86(4): 2266-2275, 2021 10.
Article em En | MEDLINE | ID: mdl-34014008
ABSTRACT

PURPOSE:

To investigate the symmetry constraint in susceptibility tensor imaging. THEORY The linear relationship between the MRI frequency shift and the magnetic susceptibility tensor is derived without constraining the tensor to be symmetric. In the asymmetric case, the system matrix is shown to be maximally rank 6. Nonetheless, relaxing the symmetry constraint may still improve tensor estimation because noise and image artifacts do not necessarily follow the constraint.

METHODS:

Gradient echo phase data are obtained from postmortem mouse brain and kidney samples. Both symmetric and asymmetric tensor reconstructions are applied to the data. The reconstructions are then used for susceptibility tensor imaging fiber tracking. Simulations with ground truth and at various noise levels are also performed. The reconstruction methods are compared qualitatively and quantitatively.

RESULTS:

Compared to regularized and unregularized symmetric reconstructions, the asymmetric reconstruction shows reduced noise and streaking artifacts, better contrast, and more complete fiber tracking. In simulation, the asymmetric reconstruction achieves better mean squared error and better angular difference in the presence of noise. Decomposing the asymmetric tensor into its symmetric and antisymmetric components confirms that the underlying susceptibility tensor is symmetric and that the main sources of asymmetry are noise and streaking artifacts.

CONCLUSION:

Whereas the susceptibility tensor is symmetric, asymmetric reconstruction is more effective in suppressing noise and artifacts, resulting in more accurate estimation of the susceptibility tensor.
Assuntos
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Encéfalo / Artefatos Limite: Animals Idioma: En Revista: Magn Reson Med Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Encéfalo / Artefatos Limite: Animals Idioma: En Revista: Magn Reson Med Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Estados Unidos