Your browser doesn't support javascript.
loading
Portable Smartphone Platform Based on a Single Dual-Emissive Ratiometric Fluorescent Probe for Visual Detection of Isopropanol in Exhaled Breath.
Yang, Fan; Lin, Dan; Pan, Lei; Zhu, Jiawei; Shen, Jianjun; Yang, Liang; Jiang, Changlong.
Afiliação
  • Yang F; Institute of Solid State Physics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui 230031, China.
  • Lin D; Department of Chemistry, University of Science and Technology of China, Hefei 230026, China.
  • Pan L; Institute of Solid State Physics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui 230031, China.
  • Zhu J; State Key Laboratory of Transducer Technology, Chinese Academy of Sciences, Hefei, Anhui 230031, China.
  • Shen J; Institute of Solid State Physics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui 230031, China.
  • Yang L; Department of Chemistry, University of Science and Technology of China, Hefei 230026, China.
  • Jiang C; Institute of Solid State Physics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui 230031, China.
Anal Chem ; 93(43): 14506-14513, 2021 11 02.
Article em En | MEDLINE | ID: mdl-34609831
The components in the exhaled breath have been confirmed to be related to certain diseases, especially studies have shown that isopropanol (IPA) might be closely associated with illnesses such as lung cancer, and are considered as a biomarker. Herein, we designed a portable smartphone platform based on a chemically synthesized ratiometric fluorescent probe for real-time/on-site, sensitive, and quantitative visual detection of IPA in exhaled breath. The fluorescent probe was fabricated by a nicotinamide adenine dinucleotide (NAD+) functional modified onto fluorescent internal standard red carbon dots (RCDs). Whereas, IPA can convert NAD+ into reduced nicotinamide adenine dinucleotide (NADH) through an enzymatic reaction of secondary alcohol dehydrogenase (S-ADH). The electron transfer from IPA to NAD+ emitted a blue emission of NADH, which displayed consecutive color changes from red to light blue. Under optimum conditions, the fluorescent probe shows sensitive responses to IPA with a detection limit as low as 4.45 nM. Moreover, combined with the smartphone color recognizer application (APP), the ratio of fluorescence intensity response was recorded on a blue channel (B)/red channel (R), which has been employed for the visual quantitative determination of IPA with a detection limit of 8.34 nM and a recovery rate of 90.65-110.09% (RSD ≤ 4.83). The method reported here provides a convenient pathway for real-time/on-site and visual detection of IPA in exhaled air and is expected to extend the application of investigation of potential volatile biomarkers for preliminary monitoring and clinical diagnosis.
Assuntos

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / 2-Propanol Tipo de estudo: Diagnostic_studies Idioma: En Revista: Anal Chem Ano de publicação: 2021 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / 2-Propanol Tipo de estudo: Diagnostic_studies Idioma: En Revista: Anal Chem Ano de publicação: 2021 Tipo de documento: Article País de afiliação: China