Your browser doesn't support javascript.
loading
Geometrical analysis for motion monitoring of rigid bodies with optical surface scanning in radiation oncology.
Dekker, Janita; van Wagenberg, Teun Pieter; de Smet, Mariska; Essers, Marion; Kusters, Martijn; de Kruijf, Willy.
Afiliação
  • Dekker J; Instituut Verbeeten, Klinische Fysica & Instrumentatie, Postbus 90120, 5000 LA Tilburg, The Netherlands.
  • van Wagenberg TP; Instituut Verbeeten, Klinische Fysica & Instrumentatie, Postbus 90120, 5000 LA Tilburg, The Netherlands.
  • de Smet M; Department of Biomedical Engineering, Eindhoven University of Technology, Den Dolech 2, 5612 AZ Eindhoven, The Netherlands.
  • Essers M; Instituut Verbeeten, Klinische Fysica & Instrumentatie, Postbus 90120, 5000 LA Tilburg, The Netherlands.
  • Kusters M; Instituut Verbeeten, Klinische Fysica & Instrumentatie, Postbus 90120, 5000 LA Tilburg, The Netherlands.
  • de Kruijf W; Department of Radiation Oncology, Radboud University Medical Center, Geert Grooteplein 32, 6525 GA Nijmegen, The Netherlands.
Phys Imaging Radiat Oncol ; 20: 105-110, 2021 Oct.
Article em En | MEDLINE | ID: mdl-34901475
BACKGROUND AND PURPOSE: Surface guided radiotherapy can be used to improve patient setup and for accurate intra-fraction motion monitoring in correspondence to the isocenter. For a clinical relevant motion analysis the actual displacement of the entire clinical target volume (CTV) is necessary. Therefore, the aim of this study was to develop a novel assessment method for intra-fraction motion for rigid body structures based on motion data and a geometrical analysis. MATERIALS AND METHODS: A threshold value on the volume coverage (VC(t)) of the CTV by the planning target volume (PTV) was proposed as online motion monitoring method. Moreover, offline analysis was performed by using heat maps and by calculating VCx, the volume coverage for at least x% of treatment time. The method was applied retrospectively to patient treatment data for whole brain radiation treatment without a thermoplastic mask. RESULTS: In 132 out of 142 fractions in total the proportion of the CTV that was inside the PTV for at least 99% of the time (VC99) was more than 95%, for a CTV-to-PTV margin of 5 mm. The source-voxel heat map showed which part of the CTV had a reduced coverage and the target heat map showed the movement of the CTV. CONCLUSION: Instead of using an action threshold on the movements of the isocenter, a threshold on the VC(t) of the CTV by the PTV was proposed. The heat maps and resulting values of VCx can be used to adapt the VC(t) threshold or the CTV-to-PTV margin for subsequent fractions.
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Idioma: En Revista: Phys Imaging Radiat Oncol Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Holanda

Texto completo: 1 Bases de dados: MEDLINE Idioma: En Revista: Phys Imaging Radiat Oncol Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Holanda