Your browser doesn't support javascript.
loading
Dual-mode detection of dopamine based on 0D/2D/2D CuInS2/ZnS quantum dot-black phosphorous nanosheet-TiO2 nanosheet nanocomposites.
Yi, Jinquan; Chen, Xiaoping; Lin, Jianwei; Song, Kai; Han, Zhizhong; Chen, Jinghua.
Afiliação
  • Yi J; School of Pharmacy, Fujian Medical University, Fuzhou, 350122, Fujian, China.
  • Chen X; Fujian Key Laboratory of Drug Target Discovery and Structural and Functional Research, Fuzhou, 350122, Fujian, China.
  • Lin J; School of Pharmacy, Fujian Medical University, Fuzhou, 350122, Fujian, China.
  • Song K; Fujian Key Laboratory of Drug Target Discovery and Structural and Functional Research, Fuzhou, 350122, Fujian, China.
  • Han Z; School of Pharmacy, Fujian Medical University, Fuzhou, 350122, Fujian, China.
  • Chen J; Fujian Key Laboratory of Drug Target Discovery and Structural and Functional Research, Fuzhou, 350122, Fujian, China.
Anal Bioanal Chem ; 414(5): 1829-1839, 2022 Feb.
Article em En | MEDLINE | ID: mdl-34988590
In this work, we designed new dual-mode "turn-on" electrochemical (EC) and photoelectrochemical (PEC) sensors for the detection of dopamine (DA) based on 0D/2D/2D CuInS2/ZnS quantum dot (QD)-black phosphorous nanosheet (BPNS)-TiO2 nanosheet (TiO2NS) nanocomposites. QDs can not only improve the photocurrent of the developed PEC sensors, but also provide the electrochemical signal in the EC detection. BPNSs as p-type semiconductor with high conductive properties work as electron acceptors and are utilized to improve the sensitivity of the DA PEC and EC sensors. Under irradiation of visible light or the applied voltage, DA is both excited and releases electrons, realizing "turn-on" detection. The PEC sensors have a linear range of 0.1-100 µM with a lower detection limit of 0.028 µM. For the EC detection, BPNSs can accelerate electron transfer which attribute to its excellent conductivity. In the range of 1-200 µM, the working curve of DA detection by the EC sensors was established and the detection limit is 0.88 µM. Comparing the two methods, the PEC sensors have a lower detection limit, and the EC sensors have a wider monitoring range. The dual-mode sensors of EC and PEC pave an effective way for the detection in biological and medical fields.
Assuntos
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Fósforo / Sulfetos / Titânio / Dopamina / Compostos de Zinco / Cobre / Pontos Quânticos / Nanoestruturas Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2022 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Fósforo / Sulfetos / Titânio / Dopamina / Compostos de Zinco / Cobre / Pontos Quânticos / Nanoestruturas Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2022 Tipo de documento: Article País de afiliação: China