Your browser doesn't support javascript.
loading
Development of Three-Stage Bioaerosol Sampler for Size-Selective Sampling.
Lim, Jun-Hyung; Nam, Sang Hwan; Kim, Jongwoo; Kim, Nam Hoon; Park, Gun-Soo; Maeng, Jin-Soo; Yook, Se-Jin.
Afiliação
  • Lim JH; School of Mechanical Engineering, Hanyang University, Seoul 04763, South Korea.
  • Nam SH; Center for Convergent Research of Emerging Virus Infection, Korea Research Institute of Chemical Technology, Yuseong, Daejeon 34114, South Korea.
  • Kim J; Center for Convergent Research of Emerging Virus Infection, Korea Research Institute of Chemical Technology, Yuseong, Daejeon 34114, South Korea.
  • Kim NH; Center for Convergent Research of Emerging Virus Infection, Korea Research Institute of Chemical Technology, Yuseong, Daejeon 34114, South Korea.
  • Park GS; Center for Convergent Research of Emerging Virus Infection, Korea Research Institute of Chemical Technology, Yuseong, Daejeon 34114, South Korea; Research Group of Food Processing, Korea Food Research Institute, Wanju, Jeonbuk 55365, South Korea.
  • Maeng JS; Center for Convergent Research of Emerging Virus Infection, Korea Research Institute of Chemical Technology, Yuseong, Daejeon 34114, South Korea; Research Group of Food Processing, Korea Food Research Institute, Wanju, Jeonbuk 55365, South Korea.
  • Yook SJ; School of Mechanical Engineering, Hanyang University, Seoul 04763, South Korea.
J Biomech Eng ; 144(7)2022 07 01.
Article em En | MEDLINE | ID: mdl-35013744
ABSTRACT
In this study, a three-stage bio-aerosol sampler with a sampling flow rate of 170 L/min was designed and fabricated for sampling the bio-aerosols released during human breathing and coughing, and its performance was evaluated. The sampler was constructed using a cyclone separator with a cutoff size of 2.5 µm as a preseparator, a multinozzle virtual impactor with a cutoff size of 0.34 µm as an aerosol concentrator, and a Bio-Sampler, which is a commercial product, for collecting bio-aerosols in a collection fluid. The collection efficiency of the sampler was evaluated through simulations and experiments. Only particles with sizes of 0.1-4 µm were selectively collected in the collection fluid. Bacteriophage bio-aerosols were sampled using the developed sampler and ACD-200 Bobcat sampler, which is a commercial product. The amounts of collected bacteriophages were compared using the polymerase chain reaction (PCR) technique. The sampling performance of the developed sampler was similar to that of the ACD-200 Bobcat sampler. Moreover, the developed sampler showed its ability to sample bio-aerosols of a specific size range and collect them directly in a collection fluid for the PCR analysis. Therefore, the developed sampler is expected to be useful for indoor environmental monitoring by effectively sampling the bio-aerosols released indoors during human breathing and coughing.
Assuntos
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Manejo de Espécimes / Monitoramento Ambiental Limite: Humans Idioma: En Revista: J Biomech Eng Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Coréia do Sul