Perfusion measurement in brain gliomas using velocity-selective arterial spin labeling: comparison with pseudo-continuous arterial spin labeling and dynamic susceptibility contrast MRI.
Eur Radiol
; 32(5): 2976-2987, 2022 May.
Article
em En
| MEDLINE
| ID: mdl-35066634
OBJECTIVES: To evaluate the performance of velocity-selective (VS) ASL among patients with untreated gliomas by comparing with both pseudo-continuous (PC) ASL and dynamic susceptibility contrast-enhanced perfusion-weighted imaging (DSC-PWI). METHODS: Forty-four consecutive patients with newly diagnosed glioma who underwent preoperative perfusion MRI including VSASL, PCASL, and DSC-PWI between 2017 and 2019 were retrospectively evaluated. Visual inspection was performed to evaluate the tumor signal intensity relative to gray matter based on 1-5 score criteria and weighted kappa was used to evaluate the pair-wise concordance between VSASL or PCASL and DSC-PWI. The relative tumor blood flow (rTBF) was measured from sampling intra-tumoral areas of hot-spot on the blood flow map and normalized against the contralateral normal gray matter blood flow. Linear regression and Bland-Altman analyses were performed to evaluate the correlation and agreement of rTBF measurements between ASL methods and DSC-PWI. The ROC analysis was constructed to determine the diagnostic performance of three perfusion methods for grading gliomas. RESULTS: TBF maps derived from VSASL were more comparable with DSC-PWI than PCASL on visual inspection (weighted kappa of 0.90 vs 0.68). In quantitative analysis, VSASL-rTBF yielded higher correlation with the values from DSC-PWI than PCASL-rTBF (R2 = 80% vs 47%, p < 0.001 for both). Both ASL and DSC-derived rTBF showed good distinction between low-grade and high-grade gliomas (p < 0.001). Compared to PCASL, VSASL yielded superior diagnostic sensitivity, specificity, and accuracy in glioma grading. CONCLUSIONS: VSASL showed great promise for accurate quantification of TBF and could potentially improve the diagnostic performance of ASL in preoperative grading of gliomas. KEY POINTS: ⢠VSASL demonstrated a greater agreement with DSC-PWI than with PCASL on visual inspection and perfusion quantification. ⢠VSASL showed a higher diagnostic sensitivity, negative predictive value, and accuracy than PCASL for glioma grading. ⢠With the advantages of insensitivity to transit delay and no need of prescribing a labeling plane, VSASL could potentially improve the diagnostic performance of ASL for a more accurate, noninvasive quantification of TBF in patients with glioma.
Palavras-chave
Texto completo:
1
Bases de dados:
MEDLINE
Assunto principal:
Neoplasias Encefálicas
/
Glioma
Tipo de estudo:
Observational_studies
/
Prognostic_studies
Limite:
Humans
Idioma:
En
Revista:
Eur Radiol
Assunto da revista:
RADIOLOGIA
Ano de publicação:
2022
Tipo de documento:
Article
País de afiliação:
China