Your browser doesn't support javascript.
loading
Anatomical Variations of the Epitympanum and the Usable Space for Middle Ear Implants Analyzed With CT-assisted Imaging Using a Tablet-based Software.
Grueninger, Ivo; Lippl, Lisa; Canis, Martin; Simon, Florian; Spiro, Judith E; Spiegel, Jennifer L; Hempel, John Martin; Müller, Joachim; Volgger, Veronika.
Afiliação
  • Grueninger I; Department of Otorhinolaryngology, University Hospital, Ludwig Maximilian University Munich, Germany.
  • Lippl L; MED-EL Medical Electronics GmbH, Innsbruck, Austria.
  • Canis M; Department of Otorhinolaryngology, University Hospital, Ludwig Maximilian University Munich, Germany.
  • Simon F; Department of Otorhinolaryngology, University Hospital, Ludwig Maximilian University Munich, Germany.
  • Spiro JE; Department of Radiology, University Hospital, Ludwig Maximilian University Munich, Germany.
  • Spiegel JL; Department of Otorhinolaryngology, University Hospital, Ludwig Maximilian University Munich, Germany.
  • Hempel JM; Department of Otorhinolaryngology, University Hospital, Ludwig Maximilian University Munich, Germany.
  • Müller J; Department of Otorhinolaryngology, University Hospital, Ludwig Maximilian University Munich, Germany.
  • Volgger V; Department of Otorhinolaryngology, University Hospital, Ludwig Maximilian University Munich, Germany.
Otol Neurotol ; 43(4): e454-e460, 2022 04 01.
Article em En | MEDLINE | ID: mdl-35213480
OBJECTIVE: To evaluate interindividual anatomical variations of the epitympanum and the usable space for implantation of active middle ear implants (AMEI) as well as the usefulness of a tablet-based software to assess individual anatomy on computed tomography (CT) scans. PATIENTS: CT scans of 126 patients, scheduled for cochlea implantation (50.8% men; 0.6-90.0 yr) without middle ear malformations or previous middle ear surgery and with slice thickness ≤0.7 mm were analyzed. MAIN OUTCOME MEASURES: Since no standardized measurements to assess the size of the epitympanum are available, relevant distances were defined according to anatomical landmarks. Three independent raters measured these distances using a tablet-based software. Interrater correlation was computed to evaluate the quality of the measurement process. Descriptive data were analyzed for validation and for evaluation of interindividual anatomical variations. Influence of age and sex on the taken measurements was assessed. RESULTS: No relevant correlation between age or sex and the anatomy of the epitympanum was found. Interrater correlation ranged from Spearman's ρ = 0.3-0.9 and there were significant differences between individual rater results for various combinations. Descriptive data revealed high interindividual anatomical variance of the epitympanum, especially regarding the distance between incus and skull base. CONCLUSION: The reported descriptive data regarding the anatomy of the epitympanum emphasizes the importance of preoperative planning, especially since the height of the epitympanum showed great interindividual variance potentially limiting implantation of AMEIs. The herein used tablet-based software seems to be convenient for preoperative assessment of individual anatomy in the hand of otosurgeons.
Assuntos

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Prótese Ossicular Limite: Female / Humans / Male Idioma: En Revista: Otol Neurotol Assunto da revista: NEUROLOGIA / OTORRINOLARINGOLOGIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Alemanha