Your browser doesn't support javascript.
loading
A 4-Week, Two-Center, Open-Label, Single-Arm Study to Evaluate the Safety and Efficacy of EOPatch in Well-Controlled Type 1 Diabetes Mellitus.
Park, Jiyun; Park, Nammi; Han, Sangjin; Lee, You-Bin; Kim, Gyuri; Jin, Sang-Man; Lee, Woo Je; Kim, Jae Hyeon.
Afiliação
  • Park J; Division of Endocrinology and Metabolism, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
  • Park N; Division of Clinical Affairs, EOFLOW Co. Ltd., Seongnam, Korea.
  • Han S; Division of Hardware Development, EOFLOW Co. Ltd., Seongnam, Korea.
  • Lee YB; Division of Endocrinology and Metabolism, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
  • Kim G; Division of Endocrinology and Metabolism, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
  • Jin SM; Division of Endocrinology and Metabolism, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
  • Lee WJ; Department of Internal Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
  • Kim JH; Division of Endocrinology and Metabolism, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
Diabetes Metab J ; 46(6): 941-947, 2022 11.
Article em En | MEDLINE | ID: mdl-35255546
ABSTRACT
This study evaluated the safety and efficacy of tubeless patch pump called EOPatch in patients with well-controlled type 1 diabetes mellitus (T1DM). This 4-week, two-center, open-label, single-arm study enrolled 10 adult patients diagnosed with T1DM with glycosylated hemoglobin less than 7.5%. The co-primary end points were patch pump usage time for one attachment and number of serious adverse events related to the patch pump. The secondary end points were total amount of insulin injected per patch and changes in glycemic parameters including continuous glucose monitoring data compared to those at study entry. The median usage time per patch was 84.00 hours (interquartile range, 64.50 to 92.50). Serious adverse events did not occur during the trial. Four weeks later, time in range 70 to 180 mg/dL was significantly improved (70.71%±17.14 % vs. 82.96%±9.14%, P=0.01). The times spent below range (<54 mg/dL) and above range (>180 mg/dL) also improved (All P<0.05). Four-week treatment with a tubeless patch pump was safe and led to clinical improvement in glycemic control.
Assuntos
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Sistemas de Infusão de Insulina / Diabetes Mellitus Tipo 1 Limite: Adult / Humans Idioma: En Revista: Diabetes Metab J Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Sistemas de Infusão de Insulina / Diabetes Mellitus Tipo 1 Limite: Adult / Humans Idioma: En Revista: Diabetes Metab J Ano de publicação: 2022 Tipo de documento: Article