Your browser doesn't support javascript.
loading
A compact, low-cost, and binary sensing (BiSense) platform for noise-free and self-validated impedimetric detection of COVID-19 infected patients.
Salahandish, Razieh; Jalali, Pezhman; Tabrizi, Hamed Osouli; Hyun, Jae Eun; Haghayegh, Fatemeh; Khalghollah, Mahmood; Zare, Azam; Berenger, Byron M; Niu, Yan Dong; Ghafar-Zadeh, Ebrahim; Sanati-Nezhad, Amir.
Afiliação
  • Salahandish R; BioMEMS and Bioinspired Microfluidic Laboratory, Department of Biomedical Engineering, University of Calgary, Calgary, Alberta, T2N 1N4, Canada; Department of Mechanical and Manufacturing Engineering, University of Calgary, University of Calgary, Calgary, Alberta, T2N 1N4, Canada.
  • Jalali P; BioMEMS and Bioinspired Microfluidic Laboratory, Department of Biomedical Engineering, University of Calgary, Calgary, Alberta, T2N 1N4, Canada.
  • Tabrizi HO; Biologically Inspired Sensors and Actuators (BioSA), Department of Electrical Engineering and Computer Science, Lassonde School of Engineering, York University, Toronto, M3J1P3, Canada.
  • Hyun JE; Department of Ecosystem and Public Health, Faculty of Veterinary Medicine, University of Calgary, Calgary, Alberta, T2N 1N4, Canada.
  • Haghayegh F; BioMEMS and Bioinspired Microfluidic Laboratory, Department of Biomedical Engineering, University of Calgary, Calgary, Alberta, T2N 1N4, Canada.
  • Khalghollah M; BioMEMS and Bioinspired Microfluidic Laboratory, Department of Biomedical Engineering, University of Calgary, Calgary, Alberta, T2N 1N4, Canada; Department of Electrical and Software Engineering, University of Calgary, Calgary, Alberta, T2N 1N4, Canada.
  • Zare A; BioMEMS and Bioinspired Microfluidic Laboratory, Department of Biomedical Engineering, University of Calgary, Calgary, Alberta, T2N 1N4, Canada.
  • Berenger BM; Department of Pathology and Laboratory Medicine, University of Calgary, 3535 Research Rd. Calgary, Alberta, T2L 1Y1, Canada; Alberta Public Health Laboratory, Alberta Precision Laboratories, 3330 Hospital Drive, Calgary, Alberta, T2N 4W4, Canada.
  • Niu YD; Department of Ecosystem and Public Health, Faculty of Veterinary Medicine, University of Calgary, Calgary, Alberta, T2N 1N4, Canada. Electronic address: dongyan.niu@ucalgary.ca.
  • Ghafar-Zadeh E; Biologically Inspired Sensors and Actuators (BioSA), Department of Electrical Engineering and Computer Science, Lassonde School of Engineering, York University, Toronto, M3J1P3, Canada. Electronic address: egz@cse.yorku.ca.
  • Sanati-Nezhad A; BioMEMS and Bioinspired Microfluidic Laboratory, Department of Biomedical Engineering, University of Calgary, Calgary, Alberta, T2N 1N4, Canada; Department of Mechanical and Manufacturing Engineering, University of Calgary, University of Calgary, Calgary, Alberta, T2N 1N4, Canada; Biomedical Enginee
Biosens Bioelectron ; 213: 114459, 2022 Oct 01.
Article em En | MEDLINE | ID: mdl-35728365

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / COVID-19 Tipo de estudo: Diagnostic_studies / Health_economic_evaluation Limite: Humans Idioma: En Revista: Biosens Bioelectron Assunto da revista: BIOTECNOLOGIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Canadá

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / COVID-19 Tipo de estudo: Diagnostic_studies / Health_economic_evaluation Limite: Humans Idioma: En Revista: Biosens Bioelectron Assunto da revista: BIOTECNOLOGIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Canadá