Your browser doesn't support javascript.
loading
Oesophageal safety in voltage-guided atrial fibrillation ablation using ablation index or contact force only: a prospective comparison.
Schade, Anja; Costello-Boerrigter, Lisa; Deneke, Thomas; Steinborn, Frank; Chapran, Mykhaylo; Vathie, Koroush; Milisavljevic, Nemanja; Franz, Marcus; Surber, Ralf; Assani, Mohamad; Hamo, Hussam; Khshfeh, Muhammed; Lauten, Alexander; Mattea, Violeta.
Afiliação
  • Schade A; Department of Cardiology/Interventional Electrophysiology, Helios Hospital Erfurt, Nordhäuser Str. 74, 99089 Erfurt, Germany.
  • Costello-Boerrigter L; Department of Cardiology and Center for Clinical Studies, Central Clinic Bad Berka, Robert-Koch-Alle 9, 99438 Bad Berka, Germany.
  • Deneke T; Department of Cardiology II/Interventional Electrophysiology, Rhoen-Klinikum Campus Bad Neustadt, Von-Guttenberg Str. 11, 97616 Bad Neustadt, Germany.
  • Steinborn F; Department of Cardiology/Interventional Electrophysiology, Helios Hospital Erfurt, Nordhäuser Str. 74, 99089 Erfurt, Germany.
  • Chapran M; Department of Cardiology/Interventional Electrophysiology, Helios Hospital Erfurt, Nordhäuser Str. 74, 99089 Erfurt, Germany.
  • Vathie K; Department of Cardiology/Interventional Electrophysiology, Helios Hospital Erfurt, Nordhäuser Str. 74, 99089 Erfurt, Germany.
  • Milisavljevic N; Department of Internal Medicine 2, Helios Hospital Erfurt, Nordhäuser Str. 74, 99089 Erfurt, Germany.
  • Franz M; Department of Internal Medicine I/Cardiology, Jena University Hospital, Am Klinikum 1, 07747 Jena, Germany.
  • Surber R; Department of Internal Medicine I/Cardiology, Jena University Hospital, Am Klinikum 1, 07747 Jena, Germany.
  • Assani M; Department of Cardiology/Interventional Electrophysiology, Helios Hospital Erfurt, Nordhäuser Str. 74, 99089 Erfurt, Germany.
  • Hamo H; Department of Cardiology/Interventional Electrophysiology, Helios Hospital Erfurt, Nordhäuser Str. 74, 99089 Erfurt, Germany.
  • Khshfeh M; Department of Cardiology/Interventional Electrophysiology, Helios Hospital Erfurt, Nordhäuser Str. 74, 99089 Erfurt, Germany.
  • Lauten A; Department of Cardiology/Interventional Electrophysiology, Helios Hospital Erfurt, Nordhäuser Str. 74, 99089 Erfurt, Germany.
  • Mattea V; Department of Cardiology/Interventional Electrophysiology, Helios Hospital Erfurt, Nordhäuser Str. 74, 99089 Erfurt, Germany.
Europace ; 24(12): 1909-1916, 2022 Dec 09.
Article em En | MEDLINE | ID: mdl-35851917
ABSTRACT

AIMS:

Left atrial ablation using radiofrequency (RF) is associated with endoscopically detected thermal oesophageal lesions (EDELs). The aim of this study was to compare EDEL occurrence after conventional contact force-guided (CFG) RF ablation vs. an ablation index-guided (AIG) approach in clinical routine of voltage-guided ablation (VGA). Predictors of EDEL were also assessed. METHODS AND

RESULTS:

This study compared CFG (n = 100) with AIG (n = 100) in consecutive atrial fibrillation ablation procedures, in which both pulmonary vein isolation and VGA were performed. In the AIG group, AI targets were ≥500 anteriorly and ≥350-400 posteriorly. Upper endoscopy was performed after ablation.The CFG and AIG groups had comparable baseline characteristics. The EDEL occurred in 6 and 5% (P = 0.86) in the CFG and AIG groups, respectively. Category 2 lesions occurred in 4 and 2% (P = 0.68), respectively. All EDEL healed under proton pump inhibitor therapy. The AI > 520 was the only predictor of EDEL [odds ratio (OR) 3.84; P = 0.039]. The more extensive Category 2 lesions were predicted by AI max > 520 during posterior ablation (OR 7.05; P = 0.042), application of posterior or roof lines (OR 5.19; P = 0.039), existence of cardiomyopathy (OR 4.93; P = 0.047), and CHA2DS2-VASc score (OR 1.71; P = 0.044). The only Category 2 lesion with AI max < 520 (467) occurred in a patient with low body mass index.

CONCLUSIONS:

Both methods were comparable with respect to clinical complications and EDEL. In consideration of previous reconnection data and our study results regarding oesophageal safety, optimal AI target range might be between 400 and 450.
Assuntos
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Veias Pulmonares / Fibrilação Atrial / Ablação por Cateter Tipo de estudo: Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: Europace Assunto da revista: CARDIOLOGIA / FISIOLOGIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Veias Pulmonares / Fibrilação Atrial / Ablação por Cateter Tipo de estudo: Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: Europace Assunto da revista: CARDIOLOGIA / FISIOLOGIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Alemanha