Your browser doesn't support javascript.
loading
Severe Tortuosity of the Distal Descending Thoracic Aorta Affects the Accuracy of Distal Deployment During a Thoracic Endovascular Aortic Repair.
Sato, Tomohiro; Banno, Hiroshi; Ikeda, Shuta; Kawai, Yohei; Tsuruoka, Takuya; Sugimoto, Masayuki; Niimi, Kiyoaki; Kodama, Akio; Komori, Kimihiro.
Afiliação
  • Sato T; Division of Vascular and Endovascular Surgery, Department of Surgery, Nagoya University Graduate School of Medicine, Nagoya, Japan.
  • Banno H; Division of Vascular and Endovascular Surgery, Department of Surgery, Nagoya University Graduate School of Medicine, Nagoya, Japan.
  • Ikeda S; Division of Vascular and Endovascular Surgery, Department of Surgery, Nagoya University Graduate School of Medicine, Nagoya, Japan.
  • Kawai Y; Division of Vascular and Endovascular Surgery, Department of Surgery, Nagoya University Graduate School of Medicine, Nagoya, Japan.
  • Tsuruoka T; Division of Vascular and Endovascular Surgery, Department of Surgery, Nagoya University Graduate School of Medicine, Nagoya, Japan.
  • Sugimoto M; Division of Vascular and Endovascular Surgery, Department of Surgery, Nagoya University Graduate School of Medicine, Nagoya, Japan.
  • Niimi K; Division of Vascular and Endovascular Surgery, Department of Surgery, Nagoya University Graduate School of Medicine, Nagoya, Japan.
  • Kodama A; Division of Vascular and Endovascular Surgery, Department of Surgery, Nagoya University Graduate School of Medicine, Nagoya, Japan.
  • Komori K; Division of Vascular and Endovascular Surgery, Department of Surgery, Nagoya University Graduate School of Medicine, Nagoya, Japan.
J Endovasc Ther ; : 15266028221141023, 2022 Dec 02.
Article em En | MEDLINE | ID: mdl-36458820
PURPOSE: An accurate distal deployment is essential for successful thoracic endovascular aortic repair (TEVAR) of a paradiaphragmatic aortic aneurysm. This study aimed to investigate the anatomical and intraoperative factors that affect the accuracy of distal deployment during TEVAR. METHODS: We conducted a retrospective review of preoperative and postoperative computed tomography scans of 426 patients undergoing TEVAR at our institution between October 2008 and May 2021, of which the stent-graft was attempted to be deployed just above the celiac axis or the superior mesenteric artery in 56 patients. Based on the anatomical factors related to the malposition (deployed >10 mm away from the target vessel) and the greater curve to the straight-line ratio (G/S ratio), the patients were categorized as severe tortuosity (n=21) and mild tortuosity (n=35) groups to compare the operative and clinical outcomes. RESULT: Stent-graft malpositioning occurred in 21 cases. Among all anatomical variables, only the G/S ratio was significantly larger in the malpositioned cases (p=0.049). A cutoff G/S ratio value of 1.15 was determined using the receiver operating curve analysis. In the severe tortuosity group, the distal end of the stent-graft was significantly farther (median: 10.0 [interquartile range (IQR): 2.5-19.5] mm vs 3.0 [0-8.0] mm; p=0.015) from the target vessel, and the tilt angle of the stent-graft's distal edge was larger (median: 21.4 [IQR: 15.8-24.5] vs 9.5 [5.5-12.5] degree; p<0.01) than that in the mild tortuosity group. Both groups were comparable for the incidence of a primary type Ib endoleak (p=0.454), a secondary type Ib endoleak (p=1.0), and the rate of distal reintervention (p=0.276). CONCLUSION: Severe tortuosity in the distal descending thoracic aorta is associated with a malpositioned and tilted distal end of the stent-graft. CLINICAL IMPACT: Thoracic endovascular aortic repair (TEVAR) for paradiaphragmatic thoracic aortic aneurysms requires accurate distal landing. In this paper, a retrospective CT analysis revealed that the greater curve to the straight-line ratio (G/S ratio) was associated to affects the malposition of the stent graft, defined as being deployed more than 10 mm away from the target vessel. Further, a comparative analysis based on the G/S ratio demonstrated that severe aortic tortuosity was associated with a more distal and tilted deployment of the stent graft.
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Idioma: En Revista: J Endovasc Ther Assunto da revista: ANGIOLOGIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Bases de dados: MEDLINE Idioma: En Revista: J Endovasc Ther Assunto da revista: ANGIOLOGIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Japão