Your browser doesn't support javascript.
loading
Data for: Reliability of mechanical ventilation during continuous chest compressions: A crossover study of transport ventilators in a human cadaver model of CPR.
Orlob, Simon; Hobisch, Christoph; Wittig, Johannes; Auinger, Daniel; Touzil, Otto; Honnef, Gabriel; Schindler, Otmar; Metnitz, Philipp; Feigl, Georg; Prause, Gerhard.
Afiliação
  • Orlob S; Division of Anesthesiology for Cardiovascular and Thoracic Surgery and Intensive Care Medicine, Department of Anaesthesiology and Intensive Care Medicine, Medical University of Graz, Auenbruggerplatz 5, Graz 8036, Austria.
  • Hobisch C; Division of General Anaesthesiology, Emergency- and Intensive Care Medicine, Department of Anaesthesiology and Intensive Care Medicine, Medical University of Graz, Auenbruggerplatz 5, Graz, Austria.
  • Wittig J; Medical University of Graz, Neue Stiftingtalstraße 6, Graz, Austria.
  • Auinger D; Research Center for Emergency Medicine, Department of Clinical Medicine, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, Aarhus, Denmark.
  • Touzil O; Department of Medicine, Randers Regional Hospital, Skovlyvej 15, Randers, Denmark.
  • Honnef G; Division of General Anaesthesiology, Emergency- and Intensive Care Medicine, Department of Anaesthesiology and Intensive Care Medicine, Medical University of Graz, Auenbruggerplatz 5, Graz, Austria.
  • Schindler O; Institute of Applied Information Processing and Communications, Graz University of Technology, Inffeldgasse 16a, Graz, Austria.
  • Metnitz P; Division of General Anaesthesiology, Emergency- and Intensive Care Medicine, Department of Anaesthesiology and Intensive Care Medicine, Medical University of Graz, Auenbruggerplatz 5, Graz, Austria.
  • Feigl G; Department of Internal and Respiratory Medicine, Intensive Care Unit Enzenbach, State Hospital Graz II, Hörgas 30, Gratwein, Austria.
  • Prause G; Division of General Anaesthesiology, Emergency- and Intensive Care Medicine, Department of Anaesthesiology and Intensive Care Medicine, Medical University of Graz, Auenbruggerplatz 5, Graz, Austria.
Data Brief ; 46: 108767, 2023 Feb.
Article em En | MEDLINE | ID: mdl-36478678
ABSTRACT
The data presented in this article relate to the research article, "Reliability of mechanical ventilation during continuous chest compressions a crossover study of transport ventilators in a human cadaver model of CPR" [1]. This article contains raw data of continuous recordings of airflow, airway and esophageal pressure during the whole experiment. Data of mechanical ventilation was obtained under ongoing chest compressions and from repetitive measurements of pressure-volume curves. All signals are presented as raw time series data with a sample rate of 200Hz for flow and 500 Hz for pressure. Additionally, we hereby publish extracted time series recordings of force and compression depth from the used automated chest compression device. Concomitantly, we report tables with time stamps from our laboratory book by which the data can be sequenced into different phases of the study protocol. We also present a dataset of derived volumes which was used for statistical analysis in our research article together with the used exclusion list. The reported dataset can help to understand mechanical properties of Thiel-embalmed cadavers better and compare different models of cardiopulmonary resuscitation (CPR). Future research may use this data to translate our findings from bench to bedside. Our recordings may become useful in developing respiratory monitors for CPR, especially in prototyping and testing algorithms of such devices.
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Revista: Data Brief Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Áustria

Texto completo: 1 Bases de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Revista: Data Brief Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Áustria