Your browser doesn't support javascript.
loading
Honeycomb resin-based spin-column solid-phase extraction for efficient determination of alectinib and its metabolite in human urine.
Zhao, Zihui; Li, Pengfei; Han, Yehong; Yan, Hongyuan.
Afiliação
  • Zhao Z; Key Laboratory of Medicinal Chemistry and Molecular Diagnosis of Ministry of Education, College of Pharmaceutical Sciences, Hebei University, Baoding 071002, China.
  • Li P; Key Laboratory of Public Health Safety of Hebei Province, College of Public Health, Hebei University, Baoding, 071002, China.
  • Han Y; Key Laboratory of Medicinal Chemistry and Molecular Diagnosis of Ministry of Education, College of Pharmaceutical Sciences, Hebei University, Baoding 071002, China.
  • Yan H; Key Laboratory of Medicinal Chemistry and Molecular Diagnosis of Ministry of Education, College of Pharmaceutical Sciences, Hebei University, Baoding 071002, China; Key Laboratory of Public Health Safety of Hebei Province, College of Public Health, Hebei University, Baoding, 071002, China. Electroni
J Chromatogr A ; 1690: 463787, 2023 Feb 08.
Article em En | MEDLINE | ID: mdl-36652815
ABSTRACT
Alectinib and its metabolite, M4, have demonstrated a satisfactory clinical therapeutic effect in the treatment of anaplastic lymphoma kinase-positive advanced non-small-cell lung cancer. Due to individual differences among patients, therapeutic drug monitoring (TDM) is critical for guaranteeing appropriate clinical drug use. To realize TDM for alectinib and its metabolite, M4, a honeycomb phenol-formaldehyde resin (PFR) with excellent hydrophilic properties, abundant adsorption force, and a stable porous structure was synthesized by modifying the porogens F127 and P123. The prepared PFR was employed as an adsorbent in a simple and efficient spin-column solid-phase extraction (SPE) process. A rapid method for detecting alectinib and its metabolite M4 in urine was thereby established. The established method showed a linear range of 0.0200 µg mL-1-5.00 µg mL-1 and the recovery range of 98.8-103% for spiked urine samples, with relative standard deviations of ≤ 4.87% (n = 3). Our results proved the practicability of the proposed honeycomb-PFR spin-column SPE method in TDM for alectinib and its metabolite, M4.
Assuntos
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Carcinoma Pulmonar de Células não Pequenas / Neoplasias Pulmonares Limite: Humans Idioma: En Revista: J Chromatogr A Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Carcinoma Pulmonar de Células não Pequenas / Neoplasias Pulmonares Limite: Humans Idioma: En Revista: J Chromatogr A Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China