Your browser doesn't support javascript.
loading
Using CT scans to determine the optimal sizes of hard armour plates to protect the torso for UK female Armed Forces personnel.
Breeze, John; Fryer, R N; Bowley, D; Gibb, I; Lewis, E.
Afiliação
  • Breeze J; Academic Department of Military Surgery and Trauma, Royal Centre for Defence Medicine, Birmingham, UK editor.bmjmilitary@bmj.com.
  • Fryer RN; Department of Bioengineering, Imperial College London, London, UK.
  • Bowley D; Platform Systems, Dstl, Fareham, UK.
  • Gibb I; Academic Department of Military Surgery and Trauma, Royal Centre for Defence Medicine, Birmingham, UK.
  • Lewis E; X-ray Department, HM Naval Base Portsmouth, Medical Centre, HMS Nelson, Portsmouth, UK.
BMJ Mil Health ; 169(1): 69-74, 2023 Feb.
Article em En | MEDLINE | ID: mdl-36657826
ABSTRACT

INTRODUCTION:

Hard armour plates provide coverage to essential anatomical structures in the torso that, if injured, would likely be responsible for death before damage control surgery can be undertaken. Existing front and rear OSPREY plates in conjunction with Mark 2 plates used at the sides in current UK Armed Forces personal armour systems are provided in a single size, used by both female and male users.

METHODS:

CT scans of 45 female UK military personnel were analysed. Distances between anatomical structures representing threshold (absolute minimum) and objective (the maximum level of coverage beyond which there is limited further benefit) coverage of the torso were determined and compared with OSPREY and Mark 2 plate dimensions. Sample characteristics were compared with the 2006/2007 UK Armed Forces Anthropometric Survey.

RESULTS:

No statistical difference was found between sample means for stature (p=0.131) and mass (p=0.853) from those of the anthropometric survey in this sample. The height of both the front OSPREY plates exceeded the threshold coverage (suprasternal notch to lower border of the 10th rib) for all women studied. The height of the Mark 2 plate exceeds the objective coverage from the side for all women studied.

CONCLUSIONS:

Based on a plate height providing threshold coverage of all women up to the 50th percentile, the height of the front and rear OSPREY plates could be reduced by 36mm and 31mm respectively. Based on a presumption that a side plate should cover up to the 95th percentile, the Mark 2 plate achieves the objective height and width for the female population studied. Strong evidence was found to support the UK Ministry of Defence requirement for procurement of new front and rear plates of multiple heights for both female and male users.
Assuntos
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Militares Limite: Female / Humans / Male País/Região como assunto: Europa Idioma: En Revista: BMJ Mil Health Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Reino Unido

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Militares Limite: Female / Humans / Male País/Região como assunto: Europa Idioma: En Revista: BMJ Mil Health Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Reino Unido