Your browser doesn't support javascript.
loading
Assessment of vibration modulated regional cerebral blood flow with MRI.
Kong, Linghan; Qiu, Suhao; Chen, Yu; He, Zhao; Huang, Peiyu; He, Qiang; Zhang, Ru-Yuan; Feng, Xi-Qiao; Deng, Linhong; Li, Yao; Yan, Fuhua; Yang, Guang-Zhong; Feng, Yuan.
Afiliação
  • Kong L; School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China; Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai, China; National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy (NERC-AMRT), Shanghai Jiao Tong
  • Qiu S; School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China; Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai, China; National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy (NERC-AMRT), Shanghai Jiao Tong
  • Chen Y; School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China; Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai, China; National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy (NERC-AMRT), Shanghai Jiao Tong
  • He Z; School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China; Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai, China; National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy (NERC-AMRT), Shanghai Jiao Tong
  • Huang P; Department of Radiology, The Second Affiliated Hospital, Zhejiang University School of Medicine, 310000, Hangzhou, China.
  • He Q; Shanghai United Imaging Healthcare Co Ltd, Shanghai, China.
  • Zhang RY; Institute of Psychology and Behavioral Science, Antai College of Economics and Management, Shanghai Jiao Tong University, Shanghai, China; Shanghai Mental Health Center Shanghai, School of Medicine, Shanghai Jiao Tong University, Shanghai, China.
  • Feng XQ; Institute of Biomechanics and Medical Engineering, Department of Engineering Mechanics, Tsinghua University, Beijing, China.
  • Deng L; Institute of Biomedical Engineering and Health Sciences, Changzhou University, Changzhou, Jiangsu 213164, China.
  • Li Y; School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.
  • Yan F; Department of Radiology, Ruijin Hospital, Shanghai, China.
  • Yang GZ; School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China; Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai, China; National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy (NERC-AMRT), Shanghai Jiao Tong
  • Feng Y; School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China; Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai, China; Department of Radiology, Ruijin Hospital, Shanghai, China; National Engineering Research Center of Advanced Magnetic Resonance Technologies
Neuroimage ; 269: 119934, 2023 04 01.
Article em En | MEDLINE | ID: mdl-36754123

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Vibração / Encéfalo Limite: Humans Idioma: En Revista: Neuroimage Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Vibração / Encéfalo Limite: Humans Idioma: En Revista: Neuroimage Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2023 Tipo de documento: Article