Your browser doesn't support javascript.
loading
Comparison of preoxygenation efficiency measured by the oxygen reserve index between high-flow nasal oxygenation and facemask ventilation: a randomised controlled trial.
Park, Sujung; Kim, So Yeon; Kim, Min-Soo; Park, Wyun Kon; Byon, Hyo-Jin; Kim, Hyun Joo.
Afiliação
  • Park S; Department of Anesthesiology and Pain Medicine, Anesthesia and Pain Research Institute, Yonsei University College of Medicine, Seoul, South Korea.
  • Kim SY; Department of Anesthesiology and Pain Medicine, Anesthesia and Pain Research Institute, Yonsei University College of Medicine, Seoul, South Korea.
  • Kim MS; Department of Anesthesiology and Pain Medicine, Anesthesia and Pain Research Institute, Yonsei University College of Medicine, Seoul, South Korea.
  • Park WK; Department of Anesthesiology and Pain Medicine, Anesthesia and Pain Research Institute, Yonsei University College of Medicine, Seoul, South Korea.
  • Byon HJ; Department of Anesthesiology and Pain Medicine, Anesthesia and Pain Research Institute, Yonsei University College of Medicine, Seoul, South Korea.
  • Kim HJ; Department of Anesthesiology and Pain Medicine, Anesthesia and Pain Research Institute, Yonsei University College of Medicine, Seoul, South Korea. jjollong@gmail.com.
BMC Anesthesiol ; 23(1): 159, 2023 05 09.
Article em En | MEDLINE | ID: mdl-37161369
BACKGROUND: High-flow nasal oxygenation and the oxygen reserve index (ORI), which is a non-invasive and innovative modality that reflects the arterial oxygen content, are used in general anaesthesia. This study compares the preoxygenation efficiency (measured by the ORI) of high-flow nasal oxygenation and facemask ventilation during the induction process. METHODS: This single-centre, two-group, randomised controlled trial included 197 patients aged ≥ 20 years who underwent orotracheal intubation for general anaesthesia for elective surgery. The patients were randomly allocated to receive preoxygenation via facemask ventilation or high-flow nasal oxygenation. The ORI was measured and compared between both groups. RESULTS: The ORI increased during preoxygenation in all patients. At 1 min of preoxygenation, the ORI was significantly higher in the high-flow nasal oxygenation group (0.34 ± 0.33) than in the facemask ventilation group (0.21 ± 0.28; P = 0.003). The highest ORI was not significantly different between the two groups (0.68 ± 0.25 in the high-flow nasal oxygenation group vs. 0.70 ± 0.28 in the facemask ventilation group; P = 0.505). CONCLUSIONS: High-flow nasal oxygenation results in an oxygenation status similar to that provided by facemask ventilation during the induction process of general anaesthesia; therefore, high-flow nasal oxygenation is a feasible preoxygenation method. TRIAL REGISTRATION: Clinicaltrials.gov (NCT04291339).
Assuntos
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Respiração / Máscaras Tipo de estudo: Clinical_trials Limite: Humans Idioma: En Revista: BMC Anesthesiol Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Coréia do Sul

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Respiração / Máscaras Tipo de estudo: Clinical_trials Limite: Humans Idioma: En Revista: BMC Anesthesiol Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Coréia do Sul