Your browser doesn't support javascript.
loading
Regional Disparities in Transvenous Lead Extraction for Cardiac Implantable Electronic Device Infection in Japan - A Descriptive Study Using the National Database Open Data.
Togashi, Shintaro; Isawa, Tsuyoshi; Honda, Taku; Furuya, Kenichi; Yamaya, Kazuhiro; Taguri, Masataka; Toyoda, Shigeru.
Afiliação
  • Togashi S; Center for Outcomes Research and Economic Evaluation for Health, National Institute of Public Health.
  • Isawa T; Department of Nursing Care, Sendai Kousei Hospital.
  • Honda T; Department of Cardiology, Sendai Kousei Hospital.
  • Furuya K; Department of Cardiology, Sendai Kousei Hospital.
  • Yamaya K; Department of Medical Technology, Sendai Kousei Hospital.
  • Taguri M; Department of Cardiovascular Surgery, Sendai Kousei Hospital.
  • Toyoda S; Department of Health Data Science, Tokyo Medical University.
Circ J ; 87(7): 1000-1006, 2023 06 23.
Article em En | MEDLINE | ID: mdl-37197942
ABSTRACT

BACKGROUND:

Because the penetration of transvenous lead extraction (TLE) for cardiac implantable electronic device (CIED) infection has not been investigated in Japan, we conducted a population-based, retrospective, descriptive study to evaluate regional disparities in the use of TLE for CIED infection and the potential undertreatment of CIED infection using a nationwide insurance claims database.Methods and 

Results:

Patients who underwent CIED implantation or generator exchange and TLE between April 2018 and March 2020 were identified. Moreover, the penetration ratio of TLE for CIED infection in each prefecture was estimated. CIED implantation and TLE were most prevalent in the age categories of 80-89 years (40.3%) and 80-89 years (36.9%), respectively. There was no correlation between the number of CIED implantations and that of TLE (rho=-0.087, 95% confidence interval -0.374 to 0.211, P=0.56). The median penetration ratio was 0.00 (interquartile range 0.00-1.29). Of the 47 prefectures, 6, comprising Okinawa, Miyagi, Okayama, Fukuoka, Tokyo, and Osaka, showed a penetration ratio ≥2.00.

CONCLUSIONS:

Our study data indicated great regional disparities in the penetration of TLE and potential undertreatment of CIED infection in Japan. Additional measures are needed to address these issues.
Assuntos
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Marca-Passo Artificial / Desfibriladores Implantáveis / Cardiopatias Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Aged80 / Humans País/Região como assunto: Asia Idioma: En Revista: Circ J Assunto da revista: ANGIOLOGIA / CARDIOLOGIA Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Marca-Passo Artificial / Desfibriladores Implantáveis / Cardiopatias Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Aged80 / Humans País/Região como assunto: Asia Idioma: En Revista: Circ J Assunto da revista: ANGIOLOGIA / CARDIOLOGIA Ano de publicação: 2023 Tipo de documento: Article