Your browser doesn't support javascript.
loading
Case Series of Ventricular Tachycardia Ablation With Pulsed-Field Ablation: Pushing Technology Further (Into the Ventricle).
Lozano-Granero, Cristina; Hirokami, Jun; Franco, Eduardo; Tohoku, Shota; Matía-Francés, Roberto; Schmidt, Boris; Hernández-Madrid, Antonio; Zamorano Gómez, José Luis; Moreno, Javier; Chun, Julian.
Afiliação
  • Lozano-Granero C; University Hospital Ramón y Cajal, Madrid, Spain; Centro de Investigación Biomédica en Red de Enfermedades Cardiovasculares, Madrid, Spain. Electronic address: cristina.lozano@hotmail.es.
  • Hirokami J; Cardioangiologisches Centrum Bethanien, Frankfurt, Germany.
  • Franco E; University Hospital Ramón y Cajal, Madrid, Spain; Centro de Investigación Biomédica en Red de Enfermedades Cardiovasculares, Madrid, Spain.
  • Tohoku S; Cardioangiologisches Centrum Bethanien, Frankfurt, Germany.
  • Matía-Francés R; University Hospital Ramón y Cajal, Madrid, Spain.
  • Schmidt B; Cardioangiologisches Centrum Bethanien, Frankfurt, Germany.
  • Hernández-Madrid A; University Hospital Ramón y Cajal, Madrid, Spain.
  • Zamorano Gómez JL; University Hospital Ramón y Cajal, Madrid, Spain; Centro de Investigación Biomédica en Red de Enfermedades Cardiovasculares, Madrid, Spain.
  • Moreno J; University Hospital Ramón y Cajal, Madrid, Spain; Centro de Investigación Biomédica en Red de Enfermedades Cardiovasculares, Madrid, Spain.
  • Chun J; Cardioangiologisches Centrum Bethanien, Frankfurt, Germany.
JACC Clin Electrophysiol ; 9(9): 1990-1994, 2023 09.
Article em En | MEDLINE | ID: mdl-37227358
ABSTRACT
Three cases of ventricular tachycardia ablation with pulsed-field ablation technology performed at 2 separate centers are reported, highlighting the advantages and disadvantages of this tool inside the ventricle its dependence on proximity rather than contact makes it useful in sites with poor stability, while the speed of application and large scope of action provided by commercially available catheters could help with ablating large diseased areas of endocardium in a fast and hemodynamically well-tolerated fashion. However, lesion depth could be insufficient for guaranteeing efficacy in preventing ventricular tachycardias originating at an epicardial site, even in the right ventricle.
Assuntos
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Taquicardia Ventricular / Ablação por Cateter Limite: Humans Idioma: En Revista: JACC Clin Electrophysiol Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Taquicardia Ventricular / Ablação por Cateter Limite: Humans Idioma: En Revista: JACC Clin Electrophysiol Ano de publicação: 2023 Tipo de documento: Article