Your browser doesn't support javascript.
loading
Imaging of Bioprosthetic Valve Dysfunction after Transcatheter Aortic Valve Implantation.
Alwan, Louhai; Bernhard, Benedikt; Brugger, Nicolas; de Marchi, Stefano F; Praz, Fabien; Windecker, Stephan; Pilgrim, Thomas; Gräni, Christoph.
Afiliação
  • Alwan L; Department of Cardiology, Inselspital, University of Bern, 3010 Bern, Switzerland.
  • Bernhard B; Department of Cardiology, Inselspital, University of Bern, 3010 Bern, Switzerland.
  • Brugger N; Department of Cardiology, Inselspital, University of Bern, 3010 Bern, Switzerland.
  • de Marchi SF; Department of Cardiology, Inselspital, University of Bern, 3010 Bern, Switzerland.
  • Praz F; Department of Cardiology, Inselspital, University of Bern, 3010 Bern, Switzerland.
  • Windecker S; Department of Cardiology, Inselspital, University of Bern, 3010 Bern, Switzerland.
  • Pilgrim T; Department of Cardiology, Inselspital, University of Bern, 3010 Bern, Switzerland.
  • Gräni C; Department of Cardiology, Inselspital, University of Bern, 3010 Bern, Switzerland.
Diagnostics (Basel) ; 13(11)2023 May 29.
Article em En | MEDLINE | ID: mdl-37296760
Transcatheter aortic valve implantation (TAVI) has become the standard of care in elderly high-risk patients with symptomatic severe aortic stenosis. Recently, TAVI has been increasingly performed in younger-, intermediate- and lower-risk populations, which underlines the need to investigate the long-term durability of bioprosthetic aortic valves. However, diagnosing bioprosthetic valve dysfunction after TAVI is challenging and only limited evidence-based criteria exist to guide therapy. Bioprosthetic valve dysfunction encompasses structural valve deterioration (SVD) resulting from degenerative changes in the valve structure and function, non-SVD resulting from intrinsic paravalvular regurgitation or patient-prosthesis mismatch, valve thrombosis, and infective endocarditis. Overlapping phenotypes, confluent pathologies, and their shared end-stage bioprosthetic valve failure complicate the differentiation of these entities. In this review, we focus on the contemporary and future roles, advantages, and limitations of imaging modalities such as echocardiography, cardiac computed tomography angiography, cardiac magnetic resonance imaging, and positron emission tomography to monitor the integrity of transcatheter heart valves.
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Idioma: En Revista: Diagnostics (Basel) Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Suíça

Texto completo: 1 Bases de dados: MEDLINE Idioma: En Revista: Diagnostics (Basel) Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Suíça