Your browser doesn't support javascript.
loading
Rapid Bacterial Detection and Gram-Identification Using Bacterially Activated, Macrophage-Membrane-Coated Nanowired-Si Surfaces in a Microfluidic Device.
Liu, Sidi; Wang, Huibo; Yu, Le; Ren, Yijin; Bouma, Hjalmar R; Liu, Jian; van der Mei, Henny C; Busscher, Henk J.
Afiliação
  • Liu S; Institute of Functional Nano & Soft Materials (FUNSOM), Jiangsu Key Laboratory for Carbon-Based Functional Materials & Devices, Soochow University, 199 Ren'ai Road, Suzhou, 215123 Jiangsu P. R. China.
  • Wang H; University of Groningen and University Medical Center Groningen, Department of Biomedical Engineering, Antonius Deusinglaan 1, 9713 AV Groningen, The Netherlands.
  • Yu L; Institute of Functional Nano & Soft Materials (FUNSOM), Jiangsu Key Laboratory for Carbon-Based Functional Materials & Devices, Soochow University, 199 Ren'ai Road, Suzhou, 215123 Jiangsu P. R. China.
  • Ren Y; Institute of Functional Nano & Soft Materials (FUNSOM), Jiangsu Key Laboratory for Carbon-Based Functional Materials & Devices, Soochow University, 199 Ren'ai Road, Suzhou, 215123 Jiangsu P. R. China.
  • Bouma HR; University of Groningen and University Medical Center of Groningen, Department of Orthodontics, Hanzeplein 1, 9700 RB Groningen, The Netherlands.
  • Liu J; University of Groningen and University Medical Center Groningen, Department of Clinical Pharmacy and Pharmacology and Department of Internal Medicine, Hanzeplein 1, 9713 GZ Groningen, The Netherlands.
  • van der Mei HC; Institute of Functional Nano & Soft Materials (FUNSOM), Jiangsu Key Laboratory for Carbon-Based Functional Materials & Devices, Soochow University, 199 Ren'ai Road, Suzhou, 215123 Jiangsu P. R. China.
  • Busscher HJ; University of Groningen and University Medical Center Groningen, Department of Biomedical Engineering, Antonius Deusinglaan 1, 9713 AV Groningen, The Netherlands.
Nano Lett ; 23(17): 8326-8330, 2023 09 13.
Article em En | MEDLINE | ID: mdl-37611221
Bacterially induced sepsis requires rapid bacterial detection and identification. Hours count for critically ill septic patients, while current culture-based detection requires at least 10 h up to several days. Here, we apply a microfluidic device equipped with a bacterially activated, macrophage-membrane-coating on nanowired-Si adsorbent surfaces for rapid, bacterial detection and Gram-identification in bacterially contaminated blood. Perfusion of suspensions of Gram-negative or Gram-positive bacteria through a microfluidic device equipped with membrane-coated adsorbent surfaces detected low (<10 CFU/mL) bacterial levels. Subsequent, in situ fluorescence-staining yielded Gram-identification for guiding antibiotic selection. In mixed Escherichia coli and Staphylococcus aureus suspensions, Gram-negative and Gram-positive bacteria were detected in the same ratios as those fixed in suspension. Results were validated with a 100% correct score by blinded evaluation (two observers) of 15 human blood samples, spiked with widely different bacterial strains or combinations of strains, demonstrating the potential of the platform for rapid (1.5 h in total) diagnosis of bacterial sepsis.
Assuntos
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Bactérias / Sepse Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Nano Lett Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Bactérias / Sepse Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Nano Lett Ano de publicação: 2023 Tipo de documento: Article