Your browser doesn't support javascript.
loading
SPOT/Dx Pilot Reanalysis and College of American Pathologists Proficiency Testing for KRAS and NRAS Demonstrate Excellent Laboratory Performance.
Zehir, Ahmet; Nardi, Valentina; Konnick, Eric Q; Lockwood, Christina M; Long, Thomas A; Sidiropoulos, Nikoletta; Souers, Rhona J; Vasalos, Patricia; Lindeman, Neal I; Moncur, Joel T.
Afiliação
  • Zehir A; From the Department of Pathology and Laboratory Medicine, Memorial Sloan Kettering Cancer Center, New York, New York (Zehir).
  • Nardi V; the Department of Pathology, Massachusetts General Hospital, Mass General Brigham, Harvard Medical School, Boston (Nardi).
  • Konnick EQ; the Department of Laboratory Medicine and Pathology, University of Washington, Seattle (Konnick, Lockwood).
  • Lockwood CM; the Department of Laboratory Medicine and Pathology, University of Washington, Seattle (Konnick, Lockwood).
  • Long TA; Biostatistics (Long, Souers) Departments, College of American Pathologists, Northfield, Illinois.
  • Sidiropoulos N; Pathology and Laboratory Medicine, University of Vermont Medical Center, Larner College of Medicine at the University of Vermont, Burlington (Sidiropoulos).
  • Souers RJ; Biostatistics (Long, Souers) Departments, College of American Pathologists, Northfield, Illinois.
  • Vasalos P; Proficiency Testing (Vasalos) Departments, College of American Pathologists, Northfield, Illinois.
  • Lindeman NI; the Department of Pathology, Weill Cornell Medicine, New York, New York (Lindeman).
  • Moncur JT; the Office of the Director, The Joint Pathology Center, Silver Spring, Maryland (Moncur).
Arch Pathol Lab Med ; 148(2): 139-148, 2024 Feb 01.
Article em En | MEDLINE | ID: mdl-37776255
ABSTRACT
CONTEXT.­ The Sustainable Predictive Oncology Therapeutics and Diagnostics quality assurance pilot study (SPOT/Dx pilot) on molecular oncology next-generation sequencing (NGS) reportedly demonstrated performance limitations of NGS laboratory-developed tests, including discrepancies with a US Food and Drug Administration-approved companion diagnostic. The SPOT/Dx pilot methods differ from those used in proficiency testing (PT) programs. OBJECTIVE.­ To reanalyze SPOT/Dx pilot data using PT program methods and compare to PT program data.Also see p. 136. DESIGN.­ The College of American Pathologists (CAP) Molecular Oncology Committee reanalyzed SPOT/Dx pilot data applying PT program methods, adjusting for confounding conditions, and compared them to CAP NGS PT program performance (2019-2022). RESULTS.­ Overall detection rates of KRAS and NRAS single-nucleotide variants (SNVs) and multinucleotide variants (MNVs) by SPOT/Dx pilot laboratories were 96.8% (716 of 740) and 81.1% (129 of 159), respectively. In CAP PT programs, the overall detection rates for the same SNVs and MNVs were 97.2% (2671 of 2748) and 91.8% (1853 of 2019), respectively. In 2022, the overall detection rate for 5 KRAS and NRAS MNVs in CAP PT programs was 97.3% (1161 of 1193). CONCLUSIONS.­ CAP PT program data demonstrate that laboratories consistently have high detection rates for KRAS and NRAS variants. The SPOT/Dx pilot has multiple design and analytic differences with established PT programs. Reanalyzed pilot data that adjust for confounding conditions demonstrate that laboratories proficiently detect SNVs and less successfully detect rare to never-observed MNVs. The SPOT/Dx pilot results are not generalizable to all molecular oncology testing and should not be used to market products or change policy affecting all molecular oncology testing.
Assuntos

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Proteínas Proto-Oncogênicas p21(ras) / Laboratórios Limite: Humans Idioma: En Revista: Arch Pathol Lab Med Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Proteínas Proto-Oncogênicas p21(ras) / Laboratórios Limite: Humans Idioma: En Revista: Arch Pathol Lab Med Ano de publicação: 2024 Tipo de documento: Article