Your browser doesn't support javascript.
loading
Utility and diagnostic accuracy of intraoperative frozen sections in hepato-pancreato-biliary surgical pathology.
Rastogi, Archana; Ashwini, N S; Rath, Indira; Bihari, Chhagan; Sasturkar, Shridhar V; Pamecha, Viniyendra.
Afiliação
  • Rastogi A; Institute of Liver & Biliary Sciences, D-1 Vasant Kunj, Delhi, 110070, India. drarchanarastogi@gmail.com.
  • Ashwini NS; Institute of Liver & Biliary Sciences, D-1 Vasant Kunj, Delhi, 110070, India.
  • Rath I; Institute of Liver & Biliary Sciences, D-1 Vasant Kunj, Delhi, 110070, India.
  • Bihari C; Institute of Liver & Biliary Sciences, D-1 Vasant Kunj, Delhi, 110070, India.
  • Sasturkar SV; Institute of Liver & Biliary Sciences, D-1 Vasant Kunj, Delhi, 110070, India.
  • Pamecha V; Institute of Liver & Biliary Sciences, D-1 Vasant Kunj, Delhi, 110070, India.
Langenbecks Arch Surg ; 408(1): 390, 2023 Oct 09.
Article em En | MEDLINE | ID: mdl-37814143
ABSTRACT
BACKGROUND AND

PURPOSE:

Hepato-pancreato-biliary (HPB) surgeries are one of the most challenging and complex procedures. Intraoperative frozen section (IFS) diagnosis plays a pivotal role in management decisions. Comprehensive large cohort studies evaluating utility of IFS in HPB malignancies are lacking. This study aimed to evaluate the accuracy of frozen section analysis and to analyse discrepancies and impact of IFS on the surgical decisions. PATIENTS AND

METHODS:

This was a retrospective study of IFS received for the HPB specimens between years 2009 and 2021. The results were compared to the permanent sections to evaluate diagnostic accuracy, sensitivity and specificity. Indications, disagreements and impact on the surgical management were analysed.

RESULTS:

A total of 1008 specimens were evaluated bile duct margin (279; 27.7%), gallbladder (203; 20.1%), liver lesions (125 cases; 12.4%), lymph nodes (147; 14.6%), pancreatic margin (120; 11.9%) and deposits (134; 13.3%). IFS were diagnosed as negative for malignancy (805; 79.9%), positive for dysplasia (8; 0.8%), suspicious for malignancy (6; 0.6%) and positive for malignancy (189; 18.8%). The overall diagnostic accuracy was 98.4%, and the discordant rate was 1.6%. The sensitivity, specificity, positive predictive value and negative predictive value were 94.7%, 99.4%, 97.5% and 98.6% respectively. The most important reason of discordant results was technical, followed by interpretational and sampling errors.

CONCLUSION:

The study demonstrates high diagnostic accuracy (98.4%) of IFS in a large dataset of HPB specimens. This comprehensive analysis apprises of the indications, errors and the impact of IFS diagnosis on subsequent HPB surgical management.
Assuntos
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Patologia Cirúrgica / Neoplasias Tipo de estudo: Diagnostic_studies / Observational_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: Langenbecks Arch Surg Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Índia

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Patologia Cirúrgica / Neoplasias Tipo de estudo: Diagnostic_studies / Observational_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: Langenbecks Arch Surg Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Índia