Your browser doesn't support javascript.
loading
Endoscopic retrograde cholangiopancreatography-related early perforations: A study of effects of procedure duration, complexity, and endoscopist experience.
Aloysius, Mark; Goyal, Hemant; Nikumbh, Tejas; Shah, Niraj James; Hammoud, Ghassan M; Mutha, Pritesh; Joseph-Talreja, Mairin; John, Savio; Aswath, Ganesh; Wadhwa, Vaibhav; Thosani, Nirav.
Afiliação
  • Aloysius M; Division of Gastroenterology, Department of Internal Medicine, SUNY Upstate Medical University, Syracuse, NY 13210, United States.
  • Goyal H; Department of Surgery, The University of Texas Health Science Center, Houston, TX 77030, United States. doc.hemant@yahoo.com.
  • Nikumbh T; Department of Internal Medicine, The Wright Center for Graduate Medical Education, Scranton, PA 18510, United States.
  • Shah NJ; Department of Medicine, Division of Digestive Diseases, The University of Missouri at Columbia, Columbia, MO 65211, United States.
  • Hammoud GM; Department of Medicine, Division of Digestive Diseases, The University of Missouri at Columbia, Columbia, MO 65211, United States.
  • Mutha P; Department of Surgery, The University of Texas Health Science Center, Houston, TX 77030, United States.
  • Joseph-Talreja M; Department of Surgery, The University of Texas Health Science Center, Houston, TX 77030, United States.
  • John S; Division of Gastroenterology, Department of Internal Medicine, SUNY Upstate Medical University, Syracuse, NY 13210, United States.
  • Aswath G; Division of Gastroenterology, Department of Internal Medicine, SUNY Upstate Medical University, Syracuse, NY 13210, United States.
  • Wadhwa V; Department of Surgery, The University of Texas Health Science Center, Houston, TX 77030, United States.
  • Thosani N; Department of Surgery, The University of Texas Health Science Center, Houston, TX 77030, United States.
World J Gastrointest Endosc ; 15(11): 641-648, 2023 Nov 16.
Article em En | MEDLINE | ID: mdl-38073762
ABSTRACT

BACKGROUND:

Perforations (Perf) during endoscopic retrograde cholangiopancreatography (ERCP) are rare (< 1%) but potentially fatal events (up to 20% mortality). Given its rarity, most data is through case series studies from centers or analysis of large databases. Although a meta-analysis has shown fewer adverse events as a composite (bleeding, pancreatitis, Perf) during ERCP performed at high-volume centers, there is very little real-world data on endoscopist and center procedural volumes, ERCP duration and complexity on the occurrence of Perf.

AIM:

To study the profile of Perf related to ERCP by center and endoscopist procedure volume, ERCP time, and complexity from a national endoscopic repository.

METHODS:

Patients from clinical outcomes research initiative-national endoscopic database (2000-2012) who underwent ERCP were stratified based on the endoscopist and center volume (quartiles), and total procedure duration and complexity grade of the ERCP based on procedure details. The effects of these variables on the Perf that occurred were studied. Continuous variables were compared between Perf and no perforations (NoPerf) using the Mann-Whitney U test as the data demonstrated significant skewness and kurtosis.

RESULTS:

A total of 14153 ERCPs were performed by 258 endoscopists, with 20 reported Perf (0.14%) among 16 endoscopists. Mean patient age in years 61.6 ± 14.8 vs 58.1 ± 18.8 (Perf vs. NoPerf, P = NS). The cannulation rate was 100% and 91.5% for Perf and NoPerf groups, respectively. 13/20 (65%) of endoscopists were high-volume performers in the 4th quartile, and 11/20 (55%) of Perf occurred in centers with the highest volumes (4th quartile). Total procedure duration in minutes was 60.1 ± 29.9 vs 40.33 ± 23.5 (Perf vs NoPerf, P < 0.001). Fluoroscopy duration in minutes was 3.3 ± 2.3 vs 3.3 ± 2.6 (Perf vs NoPerf P = NS). 50% of the procedures were complex and greater than grade 1 difficulty. 3/20 (15%) patients had prior biliary surgery. 13/20 (65%) had sphincterotomies performed with stent insertion. Peritonitis occurred in only 1/20 (0.5%).

CONCLUSION:

Overall adverse events as a composite during ERCP are known to occur at a lower rate with higher volume endoscopists and centers. However, Perf studied from the national database show prolonged and more complex procedures performed by high-volume endoscopists at high-volume centers contribute to Perf.
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Idioma: En Revista: World J Gastrointest Endosc Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Bases de dados: MEDLINE Idioma: En Revista: World J Gastrointest Endosc Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Estados Unidos