Your browser doesn't support javascript.
loading
First transaortic transcatheter aortic valve implantation with Acurate Neo: case report and technical recommendations.
Scholtz, Smita; Rudolph, Tanja K; Gilis-Januszewski, Tomasz; Bleiziffer, Sabine.
Afiliação
  • Scholtz S; Clinic for General and Interventional Cardiology/Angiology, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, Georgstr. 11, Bad Oeynhausen 32545, Germany.
  • Rudolph TK; Clinic for General and Interventional Cardiology/Angiology, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, Georgstr. 11, Bad Oeynhausen 32545, Germany.
  • Gilis-Januszewski T; Clinic of Thoracic and Cardiovascular Surgery, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, Bad Oeynhausen, Germany.
  • Bleiziffer S; Clinic of Thoracic and Cardiovascular Surgery, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, Bad Oeynhausen, Germany.
Eur Heart J Case Rep ; 8(1): ytad640, 2024 Jan.
Article em En | MEDLINE | ID: mdl-38213867
ABSTRACT

Background:

In more than 90%, transcatheter aortic valve implantation (TAVI) is performed via transfemoral access. Alternative access routes are necessary for patients with unfavourable femoral arteries. Case

summary:

We report of a 68-year-old female with symptomatic severe aortic stenosis in whom surgical aortic valve replacement was prohibited due to her severe co-morbidities. Both femoral arteries and both subclavian arteries were unsuitable for TAVI access. Surgical aortic valve replacement and transapical TAVI were deferred due to extremely high operative risk and very low originating left coronary artery of 7 mm from the annulus. Hence, we decided to implant a self-expanding TAVI device with a low risk of coronary obstruction (Acurate Neo 2 prosthesis) via transaortic approach, which to our knowledge is the first case worldwide.

Conclusion:

The present case demonstrates the feasibility of implanting the Acurate Neo 2 system via transaortic approach when certain key points are respected. Transaortic TAVI with the Acurate Neo 2 offers a minimally invasive treatment of high operative risk patients with low originating coronary arteries.
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Idioma: En Revista: Eur Heart J Case Rep Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Bases de dados: MEDLINE Idioma: En Revista: Eur Heart J Case Rep Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Alemanha