Considerations on the use of microsensors to profile dissolved H2 concentrations in microbial electrochemical reactors.
Sandfeld, Tobias; Grøn, Louise Vinther; Munoz, Laura; Meyer, Rikke Louise; Koren, Klaus; Philips, Jo.
Afiliação
  • Sandfeld T; Department of Biology, Aarhus University, Aarhus, Denmark.
  • Grøn LV; Department of Biological and Chemical Engineering, Aarhus University, Aarhus, Denmark.
  • Munoz L; Department of Biological and Chemical Engineering, Aarhus University, Aarhus, Denmark.
  • Meyer RL; Interdisciplinary Nanoscience Center, Aarhus University, Aarhus, Denmark.
  • Koren K; Department of Biology, Aarhus University, Aarhus, Denmark.
  • Philips J; Department of Biological and Chemical Engineering, Aarhus University, Aarhus, Denmark.
PLoS One ; 19(1): e0293734, 2024.
Article em En | MEDLINE | ID: mdl-38241241
ABSTRACT
Measuring the distribution and dynamics of H2 in microbial electrochemical reactors is valuable to gain insights into the processes behind novel bioelectrochemical technologies, such as microbial electrosynthesis. Here, a microsensor method to measure and profile dissolved H2 concentrations in standard H-cell reactors is described. Graphite cathodes were oriented horizontally to enable the use of a motorized microprofiling system and a stereomicroscope was used to place the H2 microsensor precisely on the cathode surface. Profiling was performed towards the gas-liquid interface, while preserving the electric connections and flushing the headspace (to maintain anoxic conditions) and under strict temperature control (to overcome the temperature sensitivity of the microsensors). This method was tested by profiling six reactors, with and without inoculation of the acetogen Sporomusa ovata, at three different time points. H2 accumulated over time in the abiotic controls, while S. ovata maintained low H2 concentrations throughout the liquid phase (< 4 µM) during the whole experimental period. These results demonstrate that this setup generated insightful H2 profiles. However, various limitations of this microsensor method were identified, as headspace flushing lowered the dissolved H2 concentrations over time. Moreover, microsensors can likely not accurately measure H2 in the immediate vicinity of the solid cathode, because the solids cathode surface obstructs H2 diffusion into the microsensor. Finally, the reactors had to be discarded after microsensor profiling. Interested users should bear these considerations in mind when applying microsensors to characterize microbial electrochemical reactors.