Your browser doesn't support javascript.
loading
Highly Responsive Bioassay for Quantification of Glucocorticoids.
Poulsen, Mathias Flensted; Overgaard, Martin; Folsted Andersen, Christian Brix; Lodberg, Andreas.
Afiliação
  • Poulsen MF; Department of Biomedicine, Aarhus University, Wilhelm Meyers Allé 3, 8000 Aarhus C, Denmark.
  • Overgaard M; Department of Clinical Research, University of Southern Denmark, 5000 Odense C, Denmark.
  • Folsted Andersen CB; Department of Clinical Biochemistry, Odense University Hospital, 5000 Odense C, Denmark.
  • Lodberg A; Department of Biomedicine, Aarhus University, Wilhelm Meyers Allé 3, 8000 Aarhus C, Denmark.
Anal Chem ; 96(5): 2000-2007, 2024 02 06.
Article em En | MEDLINE | ID: mdl-38277256
ABSTRACT
Measurement of total cortisol levels in serum samples is currently based on immunoassays or liquid chromatography-mass spectrometry (LC-MS/MS). However, measurement of bioavailable cortisol is laborious, unreliable, and inconvenient for the patient. Therefore, a new versatile assay with the ability to measure both total and bioavailable cortisol from serum represents an important supplement to the current methods. We have generated a cell-based glucocorticoid reporter assay (HEK293F-GRE). The assay was validated for cell line stability, accuracy by dilution, precision, repeatability, reproducibility, and specificity. Additionally, the assay was tested for measuring both total and bioavailable cortisol in serum. The assay showed linearity at five dilution levels with R2 = 0.98 and an accuracy between 0.8 and 1.2. Precision (CV < 20%) was validated down to 3-6 nM dexamethasone, and estimation of the total cortisol concentration was comparable to cortisol immunoassay and LC-MS/MS in most serum samples. Moreover, the assay estimated the bioavailable cortisol fraction in serum samples to a level that agreed with the literature. The HEK293F-GRE assay holds the potential to be a complementary method for estimating cortisol in clinical practice. The ability to quantify bioavailable cortisol directly from serum samples is alluring and provides an opportunity for monitored and personal dose regimens of exogenous glucocorticoids.
Assuntos

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Hidrocortisona / Glucocorticoides Limite: Humans Idioma: En Revista: Anal Chem Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Dinamarca

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Hidrocortisona / Glucocorticoides Limite: Humans Idioma: En Revista: Anal Chem Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Dinamarca