Your browser doesn't support javascript.
loading
Microfluidic AAV Purity Characterization: New Insights into Serotype and Sample Treatment Variability.
Coll De Peña, Adriana; White, James D; Mehta, Dipti R; Ben Frej, Menel; Tripathi, Anubhav.
Afiliação
  • Coll De Peña A; Center for Biomedical Engineering, School of Engineering, Brown University, Providence, Rhode Island 02912, United States.
  • White JD; Applied Genomics, Revvity, Hopkinton, Massachusetts 01748, United States.
  • Mehta DR; Applied Genomics, Revvity, Hopkinton, Massachusetts 01748, United States.
  • Ben Frej M; Applied Genomics, Revvity, Hopkinton, Massachusetts 01748, United States.
  • Tripathi A; Center for Biomedical Engineering, School of Engineering, Brown University, Providence, Rhode Island 02912, United States.
ACS Omega ; 9(3): 4027-4036, 2024 Jan 23.
Article em En | MEDLINE | ID: mdl-38284067
ABSTRACT
Despite recent advances in nucleic acid delivery systems with the success of LNP vehicles, adeno-associated virus (AAV) remains the leading platform for targeted gene delivery due to its low immunogenicity to humans, high transduction efficiency, and range of serotypes with varying tropisms. Depending on the therapeutic goals and serotype used, different production conditions may be more amenable, generating an ever-growing need for rapid yet robust analytical techniques to support the high-quality manufacturing of AAV. A critical bottleneck exists for assessing full capsids where rapid, high-throughput techniques capable of analyzing a range of serotypes are needed. Here, we present a rapid, high-throughput analytical technique, microfluidic electrophoresis, for the assessment of full capsids compatible with AAV1, AAV2, AAV6, AAV8, and AAV9 without the need for assay modifications or optimizations, and AAV5 with some constraints. The method presented in this study uses a mathematical formulation we developed previously with a reference standard to combine the independently obtained capsid protein and single-stranded DNA (ssDNA) profiles to estimate the percentage of full capsids in a sample of unknown concentration. We assessed the ability to use a single serotype (AAV8) as the reference standard regardless of the serotype of the sample being analyzed so long as the melting temperature (Tm) of the capsids is within 12 °C from the Tm of AAV8. Using this method, we are able to characterize samples ±6.1% with an average analytical turnaround time of <5 min/sample, using only 10 µL/sample at a concentration of 2.5 × 1012 VG/mL.

Texto completo: 1 Bases de dados: MEDLINE Idioma: En Revista: ACS Omega Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Bases de dados: MEDLINE Idioma: En Revista: ACS Omega Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos