[Randomized controlled study on the application effect of a new type of intravenous radiofrequency closed therapy system made in China and an imported system].
Zhonghua Wai Ke Za Zhi
; 62(3): 223-228, 2024 Mar 01.
Article
em Zh
| MEDLINE
| ID: mdl-38291638
ABSTRACT
Objective:
To compare the application effect of domestic and imported intravenous radiofrequency closure system in the treatment of primary varicose veins of lower extremities.Methods:
This single-center prospective, non-inferiority randomized controlled trial was performed in the Department of Vascular Surgery, the Fourth Affiliated Hospital, Zhejiang University School of Medicine from January 2021 to January 2022. Patients with primary varicose veins of lower extremities who met the ataxation criteria were randomly assigned to the experimental group(domestic novel venous radiofrequency closure system) or the control group(imported venous radiofrequency closure system) in a ratio of 1â¶1. The two groups of subjects were compared in terms of target vein closure rate, technical success rate, system operation performance, incidence of adverse events and incidence of serious adverse events(SAE) within 6 months after surgery. Quantitative data were compared by Mann-Whitney U test, and categorical data were compared by χ2 test and non-inferiority test.Results:
A total of 80 subjects were included in the trial (41 in the experimental group and 39 in the control group), including 27 males and 53 females, aged (M(IQR)) 55(23) years (range40 to 78 years). There were 48 cases of left lower limb and 32 cases of right lower limb. The technical success rate and system control performance between the groups were 100%.The incidence of adverse events (58.5% (24/41) vs. 61.5% (24/39), χ2=0.075, P=0.784), and the incidence of SAE (7.3% (3/41) vs. 5.1% (2/39), χ2=0.163, P=0.686) within 6 months after surgery in experimental group and control group had no statistical significance. There was one device-related adverse event in each of the two groups. In the experimental group, one patient developed endovenous heat-induced thrombosis after surgery and recovered after taking rivaroxaban tablets. One patient in the control group had pain in the upper right thigh for more than 1 day after operation, which was cured after using analgesic cream. No device-related SAE occurred. The venous closure rate of the experimental group was 100% (38/38) at 6 months after surgery, and that of the control group was 97.4% (37/38). The difference between the two groups was 2.63% (95%CI-3.19 to 8.45, Z=4.865, P<0.01), and the 95%CI lower limit of the difference in target venous closure rate between two groups was greater than the non-inferiority threshold of -10.00%.Conclusion:
The early application effect of the new domestic intravenous radiofrequency closure system in patients with primary varicose veins of lower extremities is in line with expectations, it is not inferior to the imported system.
Texto completo:
1
Bases de dados:
MEDLINE
Assunto principal:
Varizes
/
Insuficiência Venosa
Tipo de estudo:
Clinical_trials
Limite:
Adult
/
Aged
/
Female
/
Humans
/
Male
/
Middle aged
País/Região como assunto:
Asia
Idioma:
Zh
Revista:
Zhonghua Wai Ke Za Zhi
Ano de publicação:
2024
Tipo de documento:
Article
País de afiliação:
China