Your browser doesn't support javascript.
loading
The High Stability and Selectivity of Electrochemical Sensor Using Low-Cost Diamond Nanoparticles for the Detection of Anti-Cancer Drug Flutamide in Environmental Samples.
Baskaran, Nareshkumar; Prasanna, Sanjay Ballur; Lin, Yu-Chien; Duann, Yeh-Fang; Chung, Ren-Jei; Wei, Yang.
Afiliação
  • Baskaran N; Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, Taipei 10608, Taiwan.
  • Prasanna SB; Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, Taipei 10608, Taiwan.
  • Lin YC; Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, Taipei 10608, Taiwan.
  • Duann YF; School of Materials Science and Engineering, Nanyang Technological University, Singapore 639798, Singapore.
  • Chung RJ; Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, Taipei 10608, Taiwan.
  • Wei Y; Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, Taipei 10608, Taiwan.
Sensors (Basel) ; 24(3)2024 Feb 02.
Article em En | MEDLINE | ID: mdl-38339702
ABSTRACT
In this study, a novel electrochemical sensor was created by fabricating a screen-printed carbon electrode with diamond nanoparticles (DNPs/SPCE). The successful development of the sensor enabled the specific detection of the anti-cancer drug flutamide (FLT). The DNPs/SPCE demonstrated excellent conductivity, remarkable electrocatalytic activity, and swift electron transfer, all of which contribute to the advantageous monitoring of FLT. These qualities are critical for monitoring FLT levels in environmental samples. Various structural and morphological characterization techniques were employed to validate the formation of the DNPs. Remarkably, the electrochemical sensor demonstrated a wide linear response range (0.025 to 606.65 µM). Additionally, it showed a low limit of detection (0.023 µM) and high sensitivity (0.403 µA µM-1 cm-2). Furthermore, the practicability of DNPs/SPCE can be successfully employed in FLT monitoring in water bodies (pond water and river water samples) with satisfactory recoveries.
Assuntos
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Nanopartículas / Antineoplásicos Tipo de estudo: Diagnostic_studies / Health_economic_evaluation Idioma: En Revista: Sensors (Basel) Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Taiwan

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Nanopartículas / Antineoplásicos Tipo de estudo: Diagnostic_studies / Health_economic_evaluation Idioma: En Revista: Sensors (Basel) Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Taiwan