Your browser doesn't support javascript.
loading
Photoelectrochemical quenching-recovery biosensor based on NSCQDs/Fe2O3@Bi2S3 for the detection of trypsin.
Zhou, Ying; Zhang, Chenning; Bai, Shuru; Su, Jiaxue; Zhou, Xunyong; Zhao, Longshan.
Afiliação
  • Zhou Y; School of Life Sciences and Biopharmaceuticals, Shenyang Pharmaceutical University, 103 Wenhua Road Shenhe District, Shenyang, Liaoning, 110016, China.
  • Zhang C; Department of Pharmacy, Xiangyang No.1 People's Hospital, Hubei University of Medical, Xiangyang, Hubei, 441100, China.
  • Bai S; School of Life Sciences and Biopharmaceuticals, Shenyang Pharmaceutical University, 103 Wenhua Road Shenhe District, Shenyang, Liaoning, 110016, China.
  • Su J; School of Pharmacy, Shenyang Pharmaceutical University, 103 Wenhua Road Shenhe District, Shenyang, Liaoning, 110016, China.
  • Zhou X; HC Enzyme Biotech. Co. Ltd, Shenzhen, Guangdong, 518001, China.
  • Zhao L; School of Pharmacy, Shenyang Pharmaceutical University, 103 Wenhua Road Shenhe District, Shenyang, Liaoning, 110016, China. Electronic address: longshanzhao@163.com.
Anal Chim Acta ; 1297: 342361, 2024 Apr 08.
Article em En | MEDLINE | ID: mdl-38438238
ABSTRACT

BACKGROUND:

The content of trypsin will change when pancreatic diseases occur, therefore developing a high-performance method for trypsin detection is of great significance for guiding patients on medication plans and improving their prognosis. Photoelectrochemical (PEC) analysis techniques have emerged as a solution to apply for bioassays.

RESULTS:

Herein, the Fe2O3@Bi2S3 and Nitrogen and sulfur co-doped carbon quantum dots (NSCQDs) were successfully synthesized by a hydrothermal method. Subsequently, NSCQDs/Fe2O3@Bi2S3 with a photocurrent amplification effect covered on fluorine-doped tin oxide (FTO) electrode as the substrate material and apoferritin (APO) as a bio-recognition element to quench the photocurrent of the substrate material which can be excited with light. Due to the decomposition specifically between APO and trypsin, the photocurrent response increased. The linear range for trypsin detection showed satisfied results from 2 to 1000 ng mL-1 under optimal conditions, with a detection limit of 0.42 ng mL-1 and a recovery rate of 97.41 %-103.02 %, enabling efficient quantitative analysis of trypsin.

SIGNIFICANCE:

In this experiment, a PEC biosensor with simple operation, low detection limit, excellent selectivity and strong stability was successfully prepared, enabling quantitative analysis of trypsin in human serum samples through the quenching-recovery mechanism. It holds great significance for diagnosis and serves as a practical method for the detection of trypsin in the future.
Assuntos
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Pontos Quânticos Limite: Humans Idioma: En Revista: Anal Chim Acta Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Pontos Quânticos Limite: Humans Idioma: En Revista: Anal Chim Acta Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China