Your browser doesn't support javascript.
loading
Far cortical locking constructs for fixation of distal femur fractures in an Asian population: A prospective observational study.
Lim, Eic Ju; Cho, Jae-Woo; Shon, Oog-Jin; Oh, Jong-Keon; Hwang, Kyu Tae; Lee, Gwang Chul.
Afiliação
  • Lim EJ; Department of Orthopaedic Surgery, Chungbuk National University College of Medicine, Cheongju, Republic of Korea.
  • Cho JW; Department of Orthopaedic Surgery, Korea University Guro Hospital, Seoul, Republic of Korea.
  • Shon OJ; Department of Orthopaedic Surgery, Yeungnam University Medical Center, Daegu, Republic of Korea.
  • Oh JK; Department of Orthopaedic Surgery, Korea University Guro Hospital, Seoul, Republic of Korea.
  • Hwang KT; Department of Orthopedic Surgery, Hanyang University Hospital, Seoul, Republic of Korea. Electronic address: md0713@hanmail.net.
  • Lee GC; Department of Orthopaedic Surgery, School of Medicine, Chosun University, Gwangju, Republic of Korea. Electronic address: leekci@chosun.ac.kr.
J Orthop Sci ; 2024 Apr 03.
Article em En | MEDLINE | ID: mdl-38570286
ABSTRACT

BACKGROUND:

The stiffness of locked plates suppresses healing process, prompting the introduction of far cortical locking to address this issue. This study aimed to demonstrate the clinical efficacy of far cortical locking constructs in treating distal femoral fractures in an Asian population.

METHODS:

This multicenter prospective observational study was conducted at four university hospitals between February 2018 and February 2021. Demographic data, the presence of metaphyseal comminution, and surgical fixation details were recorded. Clinical outcomes, including single-leg standing, EQ-5D, and EQ-VAS scores, and radiologic outcomes, including the RUST score of each cortex, were evaluated and compared according to the presence of metaphyseal comminution.

RESULTS:

There were 37 patients (14 men and 23 women) with a mean age of 67.3 ± 11.8 years. Twenty-two patients had metaphyseal comminution (59%), and 15 presented simple fractures in metaphyseal areas. Four patients (13%) could stand on one leg >10s at 6 weeks, and 24 patients (92%) at 1 year. EQ-5D increased from 0.022 ± 0.388 to 0.692 ± 0.347, and the mean EQ-VAS 51.1 ± 13.1 to 74.1 ± 24.1 between discharge (n = 37) and post-operative 1 year (n = 33), respectively. RUST score presented increment for time, from 6.2 ± 1.8 at 6 week to 11.6 ± 1.1 at 1 year. Radiological healing demonstrated rapid increase from week 6 (16/28, 43%) to month 3 (27/31, 87%), with no obvious increase was observed in 6 months (23/26, 89%) or 12 months (25/28, 89%). Simple metaphyseal fractures presented significantly higher RUST scores at 6 weeks and 3 months, but there was no difference in RUST scores at 6 months or 1 year according to metaphyseal comminution.

CONCLUSIONS:

Plate constructs with far cortical locking screws provided safe and effective fixation for distal femoral fractures, with consistent radiological and clinical results, regardless of metaphyseal comminution.
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Idioma: En Revista: J Orthop Sci Assunto da revista: ORTOPEDIA Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Bases de dados: MEDLINE Idioma: En Revista: J Orthop Sci Assunto da revista: ORTOPEDIA Ano de publicação: 2024 Tipo de documento: Article