Your browser doesn't support javascript.
loading
Pulmonary Transit Time Assessment by CEUS in Healthy Rabbits: Feasibility, and the Effects of UCAs Dilution Concentration.
Kang, Song; Chen, Jianfeng; Zhang, He; Li, Guangyin; Liu, Yingying; Mei, Xue; Zhu, Binyang; Ai, Xin; Jiang, Shuangquan.
Afiliação
  • Kang S; Department of Ultrasound Medicine, The Second Affiliated Hospital of Harbin Medical University, Harbin, Heilongjiang, China.
  • Chen J; Department of ultrasound, Chengdu Seventh People's Hospital (Affiliated Cancer Hospital of Chengdu Medical College), Chengdu, China.
  • Zhang H; Laboratory Animal Center, The Second Affiliated Hospital of Harbin Medical University, Harbin, Heilongjiang, China.
  • Li G; Department of Ultrasound Medicine, The Second Affiliated Hospital of Harbin Medical University, Harbin, Heilongjiang, China.
  • Liu Y; Department of Ultrasound Medicine, The Second Affiliated Hospital of Harbin Medical University, Harbin, Heilongjiang, China.
  • Mei X; Department of Ultrasound Medicine, The Second Affiliated Hospital of Harbin Medical University, Harbin, Heilongjiang, China.
  • Zhu B; Department of Ultrasound Medicine, The Second Affiliated Hospital of Harbin Medical University, Harbin, Heilongjiang, China.
  • Ai X; Department of Ultrasound Medicine, The Second Affiliated Hospital of Harbin Medical University, Harbin, Heilongjiang, China.
  • Jiang S; Department of Ultrasound Medicine, The Second Affiliated Hospital of Harbin Medical University, Harbin, Heilongjiang, China.
Ultrason Imaging ; 46(3): 178-185, 2024 May.
Article em En | MEDLINE | ID: mdl-38622911
ABSTRACT
To evaluate the inter-observer variability and the intra-observer repeatability of pulmonary transit time (PTT) measurement using contrast-enhanced ultrasound (CEUS) in healthy rabbits, and assess the effects of dilution concentration of ultrasound contrast agents (UCAs) on PTT. Thirteen healthy rabbits were selected, and five concentrations UCAs of 1200, 1100, 150, 110, and 11 were injected into the right ear vein. Five digital loops were obtained from the apical 4-chamber view. Four sonographers obtained PTT by plotting the TIC of right atrium (RA) and left atrium (LA) at two time points (T1 and T2). The frame counts of the first appearance of UCAs in RA and LA had excellent inter-observer agreement, with intra-class correlations (ICC) of 0.996, 0.988, respectively. The agreement of PTT among four observers was all good at five different concentrations, with an ICC of 0.758-0.873. The reproducibility of PTT obtained by four observers at T1 and T2 was performed well, with ICC of 0.888-0.961. The median inter-observer variability across 13 rabbits was 6.5% and the median variability within 14 days for 4 observers was 1.9%, 1.7%, 2.2%, 1.9%, respectively; The PTT of 13 healthy rabbits is 1.01 ± 0.18 second. The difference of PTT between five concentrations is statistically significant. The PTT obtained by a concentration of 1200 and 1100 were higher than that of 11, while there were no significantly differences in PTT of a concentration of 11, 110, and 150. PTT measured by CEUS in rabbits is feasible, with excellent inter-observer and intra-observer reliability and reproducibility, and dilution concentration of UCAs influences PTT results.
Assuntos
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Variações Dependentes do Observador / Estudos de Viabilidade / Ultrassonografia / Meios de Contraste Limite: Animals Idioma: En Revista: Ultrason Imaging Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Variações Dependentes do Observador / Estudos de Viabilidade / Ultrassonografia / Meios de Contraste Limite: Animals Idioma: En Revista: Ultrason Imaging Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China