Your browser doesn't support javascript.
loading
Single-drop electrodeposition of nanoneedle-like bismuth on disposable graphene electrode for on-site electrochemical detection of cadmium and lead.
Promsuwan, Kiattisak; Sanguarnsak, Chanakarn; Samoson, Kritsada; Saichanapan, Jenjira; Soleh, Asamee; Saisahas, Kasrin; Wangchuk, Sangay; Limbut, Warakorn.
Afiliação
  • Promsuwan K; Division of Health and Applied Sciences, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Forensic Science Innovation and Service Center, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Center of Excellence for Trace Analysis and Biosensor, Prin
  • Sanguarnsak C; Division of Health and Applied Sciences, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Forensic Science Innovation and Service Center, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand.
  • Samoson K; Division of Health and Applied Sciences, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Forensic Science Innovation and Service Center, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Center of Excellence for Trace Analysis and Biosensor, Prin
  • Saichanapan J; Division of Health and Applied Sciences, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Forensic Science Innovation and Service Center, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand.
  • Soleh A; Forensic Science Innovation and Service Center, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Scie
  • Saisahas K; Division of Health and Applied Sciences, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Forensic Science Innovation and Service Center, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand.
  • Wangchuk S; Forensic Science Innovation and Service Center, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Scie
  • Limbut W; Division of Health and Applied Sciences, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Forensic Science Innovation and Service Center, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Center of Excellence for Trace Analysis and Biosensor, Prin
Talanta ; 276: 126179, 2024 Aug 15.
Article em En | MEDLINE | ID: mdl-38718644
ABSTRACT
A novel cost-effective disposable porous graphene electrode (P-GE) modified with bismuth nanoneedles (nano-BiNDs) is proposed as a "mercury-free" sensor for detecting heavy metals through smartphone-assisted electrochemical sensing. The P-GE was fabricated using screen-printing. Nano-BiNDs were generated on the P-GE by potentiostatic electrodeposition. Using an optimal potential of -1.20 V (vs. pseudo-Ag/AgCl) and a deposition time of 200 s, the nano-BiNDs had an average length and width of 189 ± 5 nm and 20 ± 2 nm, respectively. The analytical performances of the fabricated sensing platform were demonstrated by detecting Cd2+ and Pb2+ using square-wave anodic stripping voltammetry (SWASV) under optimized conditions. In the optimal conditions, the fabricated sensor exhibited sharp, well-defined stripping peaks for Cd2+ and Pb2+ with excellent peak-to-peak separation. The linear detection ranges were from 0.01 to 50 µg mL-1 for Cd2+ and 0.006-50 µg mL-1 for Pb2+. The detection limits for Cd2+ and Pb2+ were 3.51 and 2.10 ng mL-1, respectively. The developed portable sensor demonstrated high sensitivity, good repeatability, reproducibility, and anti-interference properties. The proposed portable sensor quantified Cd2+ and Pb2+ in commercial seaweed products with good accuracy, consistent with the results obtained using the standard ICP-OES method.
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Idioma: En Revista: Talanta Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Bases de dados: MEDLINE Idioma: En Revista: Talanta Ano de publicação: 2024 Tipo de documento: Article