Your browser doesn't support javascript.
loading
Identifying and Responding to Lead in Drinking Water in a University Setting.
Bousquet, Audrey G; Eaves, Lauren A; Haley, Kim; Catalano, David; Williams, Gregory B; Hartwell, Hadley J; Brennan, Catherine; Fry, Rebecca C.
Afiliação
  • Bousquet AG; Department of Environmental Sciences and Engineering, Gillings School of Global Public Health, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA.
  • Eaves LA; Department of Environmental Sciences and Engineering, Gillings School of Global Public Health, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA.
  • Haley K; Institute for Environmental Health Solutions, Gillings School of Global Public Health, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA.
  • Catalano D; Department of Environment, Health and Safety, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA.
  • Williams GB; Department of Environment, Health and Safety, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA.
  • Hartwell HJ; Department of Environment, Health and Safety, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA.
  • Brennan C; Department of Environmental Sciences and Engineering, Gillings School of Global Public Health, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA.
  • Fry RC; Department of Environment, Health and Safety, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA.
Article em En | MEDLINE | ID: mdl-38791777
ABSTRACT
Lead is an established neurotoxicant, and it has known associations with adverse neurodevelopmental and reproductive outcomes. Exposure to lead at any level is unsafe, and the United States (US) has enacted various federal and state legislations to regulate lead levels in drinking water in K-12 schools and childcare facilities; however, no regulations exist for higher education settings. Upon the discovery of lead in drinking water fixtures in the University of North Carolina at Chapel Hill (UNC-CH) campus, a cross-campus water testing network and sampling plan was developed and deployed. The campaign was based on the US Environmental Protection Agency's (EPA) 3Ts (Training, Testing, and Taking Action) guidance. The seven-month campaign involved 5954 tests on 3825 drinking water fixtures across 265 buildings. A total of 502 (8.43%) tests showed lead above the limit of detection (1 part per billion, ppb), which represented 422 (11.03%) fixtures. Fewer than 1.5% of the tests were above the EPA action level for public water systems (15 ppb). In conclusion, systematic testing of all the fixtures across campus was required to identify localized contamination, and each entity in the cross-campus network undertook necessary roles to generate a successful testing campaign. UNC-CH established preventative measures to test drinking water fixtures every three years, which provide a framework for other higher education institutions in responding to lead contamination.
Assuntos
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Água Potável / Chumbo Limite: Humans País/Região como assunto: America do norte Idioma: En Revista: Int J Environ Res Public Health Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Água Potável / Chumbo Limite: Humans País/Região como assunto: America do norte Idioma: En Revista: Int J Environ Res Public Health Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos