Your browser doesn't support javascript.
loading
Biomechanical Effects of Stem Extension of Tibial Components for Medial Tibial Bone Defects in Total Knee Arthroplasty: A Finite Element Study.
Kwon, Hyuck Min; Hong, Hyoung-Taek; Kim, Inuk; Cho, Byung Woo; Koh, Yong-Gon; Park, Kwan Kyu; Kang, Kyoung-Tak.
Afiliação
  • Kwon HM; Department of Orthopedic Surgery, Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea.
  • Hong HT; Department of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, Republic of Korea.
  • Kim I; Department of Orthopedic Surgery, Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea.
  • Cho BW; Department of Orthopedic Surgery, Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea.
  • Koh YG; Joint Reconstruction Center, Department of Orthopaedic Surgery, Yonsei Sarang Hospital, 10 Hyoryeong-ro, Seocho-gu, Seoul, Republic of Korea.
  • Park KK; Department of Orthopedic Surgery, Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea.
  • Kang KT; Department of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, Republic of Korea.
J Knee Surg ; 37(13): 879-886, 2024 Nov.
Article em En | MEDLINE | ID: mdl-38870990
ABSTRACT
The aim of this study was to investigate the biomechanical effects of stem extension with a medial tibial bone defect in primary total knee arthroplasty (TKA) on load distribution and stress in the proximal tibia using finite element (FE) analysis.FE simulations were performed on the tibia bone to evaluate the stress and strain on the tibia bone and bone cement. This was done to investigate the stress shielding effect, stability of the tibia plate, and the biomechanical effects in TKA models with various medial defects and different stem length models.The results demonstrated that in the bone defect model, the longer the stem, the lower the average von Mises stress on the cortical and trabecular bones. In particular, as the bone defect increased, the average von Mises stress on cortical and trabecular bones increased. The average increase in stress according to the size of the bone defect was smaller in the long stem than in the short stem. The maximal principal strain on the trabecular bone occurred mainly at the contact point on the distal end of the stem of the tibial implant. When a short stem was applied, the maximal principal strain on the trabecular bone was approximately 8% and 20% smaller than when a long stem was applied or when no stem was applied, respectively.The findings suggest that a short stem extension of the tibial component could help achieve excellent biomechanical results when performing TKA with a medial tibial bone defect.
Assuntos

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Tíbia / Artroplastia do Joelho / Análise de Elementos Finitos / Prótese do Joelho Limite: Humans Idioma: En Revista: J Knee Surg / J. knee surg / Journal of knee surgery Assunto da revista: ORTOPEDIA Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Tíbia / Artroplastia do Joelho / Análise de Elementos Finitos / Prótese do Joelho Limite: Humans Idioma: En Revista: J Knee Surg / J. knee surg / Journal of knee surgery Assunto da revista: ORTOPEDIA Ano de publicação: 2024 Tipo de documento: Article