TB PCR in BAL and EBUS-TBNA samples for the diagnosis of pulmonary and mediastinal lymph node TB: retrospective TRiBE study.
Thorax
; 79(9): 870-877, 2024 Aug 19.
Article
em En
| MEDLINE
| ID: mdl-38977374
ABSTRACT
INTRODUCTION:
The role of Xpert Ultra in bronchoalveolar lavage (BAL) and endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) samples for pulmonary and mediastinal lymph node tuberculosis (TB) remains unclear.METHODS:
This was a retrospective observational service evaluation at a tertiary TB centre in a low-incidence setting. The diagnostic indices of Xpert Ultra, smear and culture (with cytology for EBUS-TBNA samples) were compared with culture positivity or a composite reference standard of clinical TB diagnosis. Trace readouts, a new category of results for Xpert Ultra indicating low bacillary load, were analysed in two ways as a true positive or true negative result. 282 BAL and 139 EBUS-TBNA samples were included in the analysis.RESULTS:
BAL sensitivity with 95% CI against culture-confirmed pulmonary TB from BAL samples for Xpert Ultra (trace as positive) was 0.91 (0.82 to 0.98), Xpert Ultra (trace as negative) was 0.76 (0.69 to 0.83), smear was 0.38 (p=0.0009) and culture was 1.00 (0.91 to 1.00). Specificities for all the tests were ≥0.99 (0.98 to 1.00). The addition of smear to Xpert Ultra did not improve the diagnostic accuracy.EBUS-TBNA sensitivity against culture-confirmed TB from EBUS-TBNA samples for Xpert Ultra (trace as positive) was 0.71 (0.63 to 0.78), Xpert Ultra (trace as negative) was 0.59 (0.54 to 0.63), smear was 0.12 (p=0.002), culture was 1.00 (0.89 to 1.00), cytology was 0.87 (0.76 to 0.98) and rapid on-site evaluation of cytology (ROSE) was 0.92 (0.78 to 1.00). Specificities were 0.99 (0.97 to 1.00), 0.99 (0.97 to 1.00), 1.00 (0.98 to 1.00), 1.00 (0.98 to 1.00), 0.67 (0.67 to 0.68) and 0.42, respectively.CONCLUSION:
Xpert Ultra had a significantly higher sensitivity compared with smear in both BAL and EBUS-TBNA samples. Xpert Ultra had a lower sensitivity compared with culture but comparable specificity with results being available within <24 hours. Trace readings in our low-incidence setting were associated with culture positivity in all BAL samples.Palavras-chave
Texto completo:
1
Bases de dados:
MEDLINE
Assunto principal:
Tuberculose dos Linfonodos
/
Tuberculose Pulmonar
/
Líquido da Lavagem Broncoalveolar
/
Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico
Limite:
Adult
/
Aged
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
En
Revista:
Thorax
Ano de publicação:
2024
Tipo de documento:
Article