Your browser doesn't support javascript.
loading
Development of dispersive solid phase extraction method for the preconcentration of parathion ethyl as a simulant of nerve agent sarin from soil, plant and water samples prior to GC-MS determination.
Bodur, Süleyman; Bodur, Sezin Erarpat; Tutar, Bahar Karademir; Bakirdere, Sezgin; Yagmuroglu, Ozan.
Afiliação
  • Bodur S; Chemistry Department, Yildiz Technical University, 34220, Istanbul, Türkiye.
  • Bodur SE; Faculty of Pharmacy, Department of Analytical Chemistry, Istinye University, 34010, Istanbul, Türkiye.
  • Tutar BK; Scientific and Technological Research Application and Research Center, Istinye University, 34010, Istanbul, Türkiye.
  • Bakirdere S; Chemistry Department, Yildiz Technical University, 34220, Istanbul, Türkiye.
  • Yagmuroglu O; Chemistry Department, Yildiz Technical University, 34220, Istanbul, Türkiye.
Environ Monit Assess ; 196(9): 829, 2024 Aug 21.
Article em En | MEDLINE | ID: mdl-39167268
ABSTRACT
In the presented study, an efficient and fast analytical method was developed for the determination of parathion ethyl as sarin simulant by gas chromatography-mass spectrometry (GC-MS). Dispersive solid phase extraction (DSPE) was performed to concentrate parathion ethyl from soil, plant and water samples. Reduced graphene oxide-iron (II, III) oxide (rGO-Fe3O4) nanocomposite was used as an adsorbent to collect the target analyte from the aqueous sample solutions. After the optimization of extraction/preconcentration parameters, optimum conditions for adsorbent amount, eluent type, mixing type/period, eluent volume and initial sample volume were determined as 15 mg, acetonitrile, vortex/30 s, 100 µL and 10 mL, respectively. Under the optimum conditions, analytical performance of the developed DSPE-GC-MS method was evaluated in terms of limit of detection (LOD), limit of quantitation (LOQ) and dynamic range. Dynamic range, LOD and LOQ values were figured out to be 0.94-235.15 µg/kg, 0.41 µg/kg and 1.36 µg/kg (mass based), respectively. Satisfactory percent recovery results (90.3-125% for soil, 93.5-108.7% for plant, 88.5-112.9% for tap water) were achieved for soil, plant and tap water samples which proved the accuracy and applicability of the developed method. It is predicted that the DSPE-GC-MS method can be accurately used for the detection of sarin in soil, plant and water samples taken from war territories.
Assuntos
Palavras-chave

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Sarina / Solo / Poluentes do Solo / Poluentes Químicos da Água / Extração em Fase Sólida / Cromatografia Gasosa-Espectrometria de Massas Idioma: En Revista: Environ Monit Assess Assunto da revista: SAUDE AMBIENTAL Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Bases de dados: MEDLINE Assunto principal: Sarina / Solo / Poluentes do Solo / Poluentes Químicos da Água / Extração em Fase Sólida / Cromatografia Gasosa-Espectrometria de Massas Idioma: En Revista: Environ Monit Assess Assunto da revista: SAUDE AMBIENTAL Ano de publicação: 2024 Tipo de documento: Article