Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 334
Filtrar
1.
Clin Chem Lab Med ; 62(4): 698-705, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-37882772

RESUMO

OBJECTIVES: Blood biomarkers have the potential to transform diagnosis and prognosis for multiple neurological indications. Establishing normative data is a critical benchmark in the analytical validation process. Normative data are important in children as little is known about how brain development may impact potential biomarkers. The objective of this study is to generate pediatric reference intervals (RIs) for serum neurofilament light (NfL), an axonal marker, and glial fibrillary acidic protein (GFAP), an astrocytic marker. METHODS: Serum from healthy children and adolescents aged 1 to <19 years were obtained from the Canadian Laboratory Initiative on Pediatric Reference Intervals (CALIPER) cohort. Serum NfL (n=300) and GFAP (n=316) were quantified using Simoa technology, and discrete RI (2.5th and 97.5th percentiles) and continuous RI (5th and 95th percentiles) were generated. RESULTS: While there was no association with sex, there was a statistically significant (p<0.0001) negative association between age and serum NfL (Rho -0.400) and GFAP (Rho -0.749). Two statistically significant age partitions were generated for NfL: age 1 to <10 years (lower, upper limit; 3.13, 20.6 pg/mL) and 10 to <19 years (1.82, 7.44 pg/mL). For GFAP, three statistically significant age partitions were generated: age 1 to <3.5 years (80.4, 601 pg/mL); 3.5 to <11 years (50.7, 224 pg/mL); and 11 to <19 years (26.2, 119 pg/mL). CONCLUSIONS: Taken together with the literature on adults, NfL and GFAP display U-shaped curves with high levels in infants, decreasing levels during childhood, a plateau during adolescence and early adulthood and increasing levels in seniors. These normative data are expected to inform future pediatric studies on the importance of age on neurological blood biomarkers.


Assuntos
Filamentos Intermediários , Soro , Adulto , Adolescente , Humanos , Criança , Proteína Glial Fibrilar Ácida , Prognóstico , Biomarcadores , Proteínas de Neurofilamentos
2.
Pediatr Nephrol ; 39(4): 1177-1183, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37875730

RESUMO

BACKGROUND: A new cystatin C based European Kidney Function Consortium (EKFCCysC) equation was recently developed for adults, using the same mathematical form as the previously published full age spectrum creatinine based EKFC-equation (EKFCCrea). In the present study the cystatin C based EKFC-equation is extended to children, by defining the appropriate cystatin C rescaling factor QCysC. METHODS: Rescaling factor QCysC for cystatin C was defined as: a) 0.83 mg/L, exactly as it was defined for young adults in the adult equation, and b) a more complex QCysC-age relationship based on 4th degree cystatin C-age polynomials after evaluation of data from Uppsala, Stockholm and Canada and aggregated data from Germany. The EKFCCysC equation was then validated in an independent dataset in European children (n = 2,293) with measured GFR, creatinine, cystatin C, age, height and sex available. RESULTS: The EKFCCysC with the simple QCysC-value of 0.83 had a bias of -7.6 [95%CI -8.4;-6.5] mL/min/1.73 m2 and a P30-value of 85.8% [95%CI 84.4;87.3] equal to the EKFCCysC with the more complex 4th degree QCysC-value. The arithmetic mean of the EKFCCrea and EKFCCysC with the simple QCysC of 0.83 had a bias of -4.0 [95%CI -4.5;-3.1] mL/min/1.73 m2 and P30 of 90.4% [95%CI 89.2;91.6] similar to using the more complex 4th degree QCysC-polynomial. CONCLUSION: Using exactly the same QCysC of 0.83 mg/L, the adult EKFCCysC can easily be extended to children, with some bias but acceptable P30-values. The arithmetic mean of EKFCCrea and EKFCCysC results in bias closer to zero and P30 slightly over 90%.


Assuntos
Algoritmos , Cistatina C , Rim , Criança , Humanos , Adulto Jovem , Creatinina , Cistatina C/análise , Europa (Continente) , Taxa de Filtração Glomerular , Insuficiência Renal Crônica , Rim/química , Rim/fisiologia
3.
Paediatr Child Health ; 29(3): 135-143, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38827372

RESUMO

Background and Objectives: Significant practice variation exists in managing young infants with fever. Quality improvement strategies can aid in risk stratification and standardization of best care practices, along with a reduction of unnecessary interventions. The aim of this initiative was to safely reduce unnecessary admissions, antibiotics, and lumbar punctures (LPs) by 10% in low-risk, febrile infants aged 29 to 90 days presenting to the emergency department (ED) over a 12-month period. Methods: Using the Model for Improvement, a multidisciplinary team developed a multipronged intervention: an updated clinical decision tool (CDT), procalcitonin (PCT) adoption, education, a feedback tool, and best practice advisory (BPA) banner. Outcome measures included the proportion of low-risk infants that were admitted, received antibiotics, and had LPs. Process measures were adherence to the CDT and percentage of PCT ordered. Missed bacterial infections and return visits were balancing measures. The analysis was completed using descriptive statistics and statistical process control methods. Results: Five hundred and sixteen patients less than 90 days of age were included in the study, with 403 patients in the 29- to 90-day old subset of primary interest. In the low-risk group, a reduction in hospital admissions from a mean of 24.1% to 12.0% and a reduction in antibiotics from a mean of 15.2% to 1.3% was achieved. The mean proportion of LPs performed decreased in the intervention period from 7.5% to 1.8%, but special cause variation was not detected. Adherence to the CDT increased from 70.4% to 90.9% and PCT was ordered in 92.3% of cases. The proportion of missed bacterial infections was 0.3% at baseline and 0.5% in the intervention period while return visits were 6.7% at baseline and 5.0% in the intervention period. Conclusions: The implementation of a quality improvement strategy, including an updated evidence-based CDT for young infant fever incorporating PCT, safely reduced unnecessary care in low-risk, febrile infants aged 29 to 90 days in the ED. Purpose: To develop and implement a multipronged improvement strategy including an evidence-based CDT utilizing PCT to maximize value of care delivered to well-appearing, febrile infants presenting to EDs.

4.
J Cell Mol Med ; 27(1): 158-162, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36524863

RESUMO

Age and sex need to be considered in the establishment of reference intervals (RIs), especially in early life when there are dynamic physiological changes. Since data for important biomarkers in healthy neonates and infants are limited, particularly in Iranian populations, we have determined age-specific RIs for 7 laboratory biochemical parameters. This cross-sectional study comprised a total of 344 paediatric participants (males: 158, females: 186) between the ages of 3 days and 30 months (mean age: 12.91 ± 7.15 months). Serum levels of creatinine, urea, uric acid, calcium, phosphate, vitamin D and high-sensitivity C-reactive protein (hs-CRP) were measured using an Alpha classic-AT plus auto-analyser. We determined age-specific RIs using CLSI Ep28-A3 and C28-A3 guidelines. No sex partitioning was required for any of the biomarkers. Age partitioning was required for kidney function tests and phosphate. The serum concentration of urea and creatinine increased with age, while phosphate and uric acid decreased with age. Age partitioning was not required for serum calcium, vitamin D, and hs-CRP, which remained relatively constant throughout the age range. Age-specific RIs for 7 routine biochemical markers were determined to address critical gaps in RIs in early life to help improve clinical interpretation of blood test results in young children, including neonates. Established age partitions demonstrate the biochemical changes that take place during child growth and development. These novel data will ultimately better disease management in the Iranian paediatric population and can be of value to clinical and hospital laboratories with similar populations.


Assuntos
Proteína C-Reativa , Cálcio , Masculino , Recém-Nascido , Feminino , Humanos , Criança , Lactente , Pré-Escolar , Irã (Geográfico) , Creatinina , Estudos Transversais , Ácido Úrico , Valores de Referência , Biomarcadores , Vitaminas , Ureia , Vitamina D , Fatores Etários
5.
Clin Chem ; 69(9): 991-1008, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37478022

RESUMO

BACKGROUND: Harmonization in laboratory medicine is essential for consistent and accurate clinical decision-making. There is significant and unwarranted variation in reference intervals (RIs) used by laboratories for assays with established analytical traceability. The Canadian Society of Clinical Chemists (CSCC) Working Group on Reference Interval Harmonization (hRI-WG) aims to establish harmonized RIs (hRIs) for laboratory tests and support implementation. METHODS: Harnessing the power of big data, laboratory results were collected across populations and testing platforms to derive common adult RIs for 16 biochemical markers. A novel comprehensive approach was established, including: (a) analysis of big data from community laboratories across Canada; (b) statistical evaluation of age, sex, and analytical differences; (c) derivation of hRIs using the refineR method; and (d) verification of proposed hRIs across 9 laboratories with different instrumentation using serum and plasma samples collected from healthy Canadian adults. RESULTS: Harmonized RIs were calculated for all assays using the refineR method, except free thyroxine. Derived hRIs met proposed verification criterion across 9 laboratories and 5 manufacturers for alkaline phosphatase, albumin (bromocresol green), chloride, lactate dehydrogenase, magnesium, phosphate, potassium (serum), and total protein (serum). Further investigation is needed for some analytes due to failure to meet verification criteria in one or more laboratories (albumin [bromocresol purple], calcium, total carbon dioxide, total bilirubin, and sodium) or concern regarding excessively wide hRIs (alanine aminotransferase, creatinine, and thyroid stimulating hormone). CONCLUSIONS: We report a novel data-driven approach for RI harmonization. Findings support feasibility of RI harmonization for several analytes; however, some presented challenges, highlighting limitations that need to be considered in harmonization and big data analytics.


Assuntos
Ciência de Dados , Laboratórios , Adulto , Humanos , Valores de Referência , Canadá , Albuminas
6.
Clin Chem ; 69(12): 1374-1384, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37947280

RESUMO

BACKGROUND: Physiological changes during pregnancy invalidate use of general population reference intervals (RIs) for pregnant people. The complete blood count (CBC) is commonly ordered during pregnancy, but few studies have established pregnancy RIs suitable for contemporary Canadian mothers. Prospective RI studies are challenging to perform during pregnancy while retrospective techniques fall short as pregnancy and health status are not readily available in the laboratory information system (LIS). This study derived pregnancy RIs retrospectively using LIS data linked to provincial perinatal registry data. METHODS: A 5-year healthy pregnancy cohort was defined from the British Columbia Perinatal Data Registry and linked to laboratory data from two laboratories. CBC and differential RIs were calculated using direct and indirect approaches. Impacts of maternal and pregnancy characteristics, such as age, body mass index, and ethnicity, on laboratory values were also assessed. RESULTS: The cohort contained 143 106 unique term singleton pregnancies, linked to >972 000 CBC results. RIs were calculated by trimester and gestational week. Result trends throughout gestation aligned with previous reports in the literature, although differences in exact RI limits were seen for many tests. Trimester-specific bins may not be appropriate for several CBC parameters that change rapidly within trimesters, including red blood cells (RBCs), some leukocyte parameters, and platelet counts. CONCLUSIONS: Combining information from comprehensive clinical databases with LIS data provides a robust and reliable means for deriving pregnancy RIs. The present analysis also illustrates limitations of using conventional trimester bins during pregnancy, supporting use of gestational age or empirically derived bins for defining CBC normal values during pregnancy.


Assuntos
Hematologia , Gravidez , Feminino , Humanos , Estudos Retrospectivos , Estudos Prospectivos , Canadá , Contagem de Células Sanguíneas , Valores de Referência
7.
Rheumatology (Oxford) ; 62(10): 3416-3420, 2023 10 03.
Artigo em Inglês | MEDLINE | ID: mdl-36912668

RESUMO

OBJECTIVES: Cardiac involvement in neonatal lupus erythematosis (NLE) can present as myocarditis/endocardial fibroelastosis (EFE). It is unknown whether high-sensitivity cardiac troponin T (hs-cTnT) is useful in identifying subclinical myocardial inflammation in infants exposed prenatally to anti-Ro antibodies. This study reports hs-cTnT levels in infants exposed to anti-Ro antibodies with/without cardiac NLE and reports cardiac MRI (CMR) findings in a subset of these children. METHODS: The study included 45 consecutive infants exposed prenatally to anti-Ro antibodies with (n = 7) or without (n = 38) cardiac NLE, who were seen at the SickKids NLE Clinic between 2012 and 2014. Hs-cTnT levels were measured at least once, and those infants with values of ≥30 ng/l were offered the opportunity to undergo CMR. Descriptive statistics were performed. RESULTS: Of 38 infants without cardiac NLE, 25 had a hs-cTnT level of ≥30 ng/l (including 1 of >113 ng/l); of these, 8 underwent CMR (all without myocarditis/EFE). All 7 infants with cardiac NLE had at least one hs-cTnT level of ≥30 ng/l, but only 2/7 had a level of >113 ng/l; 4/7 infants with cardiac NLE had CMR (all without myocarditis/EFE); 6/7 infants with cardiac NLE had their steroid treatment adjusted based on the trend in their hs-cTnT levels. CONCLUSION: Only 3/45 anti-Ro antibodies-exposed infants had hs-cTnT values outside the reference range reported in healthy infants. None of 12 infants who had CMR had subclinical myocarditis/EFE. Routine measurement of hs-cTnT in every anti-Ro antibody-exposed infant is not indicated. Further studies are needed to define the role of hs-cTnT as a biomarker for cardiac NLE.


Assuntos
Miocardite , Troponina T , Recém-Nascido , Criança , Humanos , Lactente , Coração , Biomarcadores
8.
Clin Chem Lab Med ; 61(4): 666-673, 2023 03 28.
Artigo em Inglês | MEDLINE | ID: mdl-36436024

RESUMO

Clinical laboratories play a vital role in the healthcare system. Objective medical data provided by clinical laboratories supports approximately 60-70% of clinical decisions, however, evidence supporting this claim is poorly documented and laboratories still lack visibility, despite their indisputable impact on patient care and public health. The International Federation for Clinical Chemistry and Laboratory Medicine (IFCC) Task Force on Outcome Studies in Laboratory Medicine (TF-OSLM) was recently developed to support directed research evaluating the role of laboratory medicine on clinical outcomes. Establishing and documenting this evidence is key to enhance visibility of the field in the eye of the public and other healthcare professionals together with optimizing patient outcomes and health care system operations. In this review, we discuss four areas that exemplify the contribution of laboratory medicine directly to patient care. This includes high-sensitivity cardiac troponin (hs-cTn) and N-terminal pro-B-type natriuretic peptide/B-type natriuretic peptides (NT-proBNP/BNP) for the diagnosis and prognosis of myocardial infarction and heart failure, respectively, and procalcitonin for the management of sepsis and antibiotic stewardship. Emerging markers of traumatic brain injury and the role of laboratory medicine in the fight against the COVID-19 pandemic are discussed along with an introduction to plans of IFCC TF-OSLM.


Assuntos
COVID-19 , Laboratórios , Humanos , Saúde Pública , Pandemias , Prognóstico , Peptídeo Natriurético Encefálico , Assistência ao Paciente , Fragmentos de Peptídeos , Biomarcadores
9.
Clin Chem Lab Med ; 61(6): 1105-1115, 2023 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-36639844

RESUMO

OBJECTIVES: Marked physiological changes in growth and development present challenges in defining pediatric reference intervals for biomarkers of health and disease. Lambda, Mu, and Sigma (LMS)-based statistical modeling provides a continuous normal distribution by negating skewness and variation, and is commonly used to establish growth charts. Such LMS reference curves are suggested to enhance laboratory test result interpretation. The current study establishes LMS-based continuous reference percentiles for 14 biomarkers in the CALIPER cohort of healthy children and adolescents. METHODS: Data from healthy children and adolescents aged 1-<19 years were used to establish continuous reference percentiles using a novel LMS-based statistical method, including 2.5th, 25th, 50th, 75th, and 97.5th percentiles. The LMS approach applies a Box-Cox data transformation and summarizes continuous distributions by age via three curves: skewness (Lambda), median (Mu), and coefficient of variation (Sigma). RESULTS: LMS-based percentiles and z-scores were generated for 14 common pediatric biomarkers that demonstrate dynamic concentration patterns with age (e.g., alkaline phosphatase) and/or wherein the magnitude of difference from the population mean may be clinically relevant (e.g., triglycerides). The LMS model captured age- and sex-specific distributions accurately and was not substantially influenced by outlying points. CONCLUSIONS: This is the first study to establish LMS-based continuous reference percentiles for biochemical markers in a healthy Canadian pediatric population. The current LMS-based approach builds upon previous continuous reference interval models by providing graded percentiles to improve test result interpretation, particularly with repeated measures over time. This method may assist in facilitating a patient-centered approach to laboratory medicine.


Assuntos
Modelos Estatísticos , Adolescente , Criança , Feminino , Humanos , Masculino , Biomarcadores , Canadá , Valores de Referência , Lactente , Pré-Escolar , Adulto Jovem
10.
Clin Chem Lab Med ; 61(3): 402-406, 2023 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-36457149

RESUMO

Reference intervals are established either by direct or indirect approaches. Whereas the definition of direct is well established, the definition of indirect is still a matter of debate. In this paper, a general definition that covers all indirect models presently in use is proposed. With the upcoming popularity of indirect models, it has become evident that further partitioning strategies are required to minimize the risk of patients' false classifications. With indirect methods, such partitions are much easier to execute than with direct methods. The authors believe that the future of reference interval estimation belongs to indirect models with big data pools either from one laboratory or combined from several regional centres (if necessary). Independent of the approach applied, the quality assurance of the pre-analytical and analytical phase, considering biological variables and other confounding factors, is essential.


Assuntos
Big Data , Laboratórios , Humanos , Valores de Referência
11.
Clin Chem Lab Med ; 61(11): 2033-2040, 2023 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-37114851

RESUMO

OBJECTIVES: Special chemistry parameters are useful in the diagnosis and management of inherited disorders, liver disease, and immunopathology. Evidence-based pediatric reference intervals (RIs) are required for appropriate clinical decision-making and need to be verified as new assays are developed. This study aimed to evaluate the applicability of pediatric RIs established for biochemical markers on the ARCHITECT for use on newer Alinity assays. METHODS: An initial method validation was completed for 16 assays, including precision, linearity, and method comparison. Sera collected from approximately 100 healthy children and adolescents as part of the Canadian Laboratory Initiative on Pediatric Reference Intervals (CALIPER) were also analyzed on the Alinity c system. Percentage of results within established ARCHITECT RIs were calculated and considered verified if ≥90 % fell within established limits. New RIs were established for three electrolytes, glucose, and lactate wherein no data were previously reported. RESULTS: Of the 11 assays for which CALIPER pediatric RIs were previously established on ARCHITECT assays, 10 met the verification criteria. Alpha-1-antitrypsin did not meet verification criterion and a new RI was established. For the other 5 assays, de novo RIs were derived following analysis of 139-168 samples from healthy children and adolescents. None required age- and sex-partitioning. CONCLUSIONS: Herein, pediatric RIs were verified or established for 16 chemistry markers in the CALIPER cohort on Alinity assays. Findings support excellent concordance between ARCHITECT and Alinity assays with one exception (alpha-1-antitrypsin) as well as robustness of age- and sex-specific patterns originally reported by CALIPER in healthy Canadian children and adolescents.


Assuntos
Laboratórios , Soro , Masculino , Feminino , Criança , Humanos , Adolescente , Valores de Referência , Biomarcadores , Ácido Láctico
12.
Clin Chem Lab Med ; 61(1): 123-132, 2023 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-36117243

RESUMO

OBJECTIVES: Clinical laboratory investigation of autoimmune, metabolic, and oncologic disorders in children and adolescents relies on appropriateness of reference intervals (RIs). The Canadian Laboratory Initiative on Pediatric Reference Intervals (CALIPER) previously established comprehensive pediatric RIs for specialized immunoassays on the Abbott ARCHITECT system. Herein, we aim to verify performance on new Alinity i assays by evaluating sera collected from healthy children as per Clinical and Laboratory Standards Institute (CLSI) EP-28A3C guidelines. METHODS: Precision, linearity, and method comparison experiments were completed for 17 specialized Alinity immunoassays, including cancer antigens, autoimmune peptides, and hormones. Sera collected from healthy children and adolescents (birth-18 years, n=100) were evaluated. CLSI-based verification was completed using previously established CALIPER RIs for ARCHITECT assays as the reference. RESULTS: Of 17 specialized immunoassays assays, only anti-cyclic citrullinated peptides (anti-CCP) did not meet acceptable verification criterion (i.e., ≥90% of results within ARCHITECT reference CI). Anti-thyroglobulin, anti-thyroid peroxidase, and carcinoembryonic antigen did not require age-specific consideration beyond one year of age, with 63, 91, and 80% of samples equalling the limit of detection, respectively. Estimates were separated by sex for relevant assays (e.g., sex hormone binding globulin, total and free prostate specific antigen). CONCLUSIONS: Findings support transferability of pediatric RIs on ARCHITECT system to the Alinity system for 16 specialized immunoassays in the CALIPER cohort and will be a useful resource for pediatric clinical laboratories using Alinity assays. Further work is needed to establish evidence-based interpretative recommendations for anti-CCP and continue to evaluate pediatric RI acceptability for newly available assay technologies.


Assuntos
Anticorpos Antiproteína Citrulinada , Neoplasias , Masculino , Criança , Humanos , Adolescente , Valores de Referência , Imunoensaio , Estudos de Coortes , Neoplasias/diagnóstico
13.
Clin Chem Lab Med ; 61(10): 1820-1828, 2023 09 26.
Artigo em Inglês | MEDLINE | ID: mdl-37036784

RESUMO

OBJECTIVES: Monitoring estradiol (E2) is important for determining the onset of pubertal development as well as in the evaluation of girls with precocious puberty. However, E2 measurement remains an analytical challenge in children, who have lower circulating levels. We developed and evaluated a simple and sensitive LC-MS/MS procedure for serum E2 quantification in pediatric populations and established age- and sex-specific pediatric reference intervals. METHODS: Residual patient serum samples were used to evaluate the analytical performance of our in-house LC-MS/MS E2 assay. The evaluation included accuracy, precision, linearity, functional sensitivity (LLoQ), and method comparison. Age- and sex-specific pediatric E2 reference intervals were also established from a cohort of 405 healthy children (birth to 18 years) recruited with informed consent. Age- and sex-specific differences were assessed, and outliers were removed. Reference intervals were established using the robust method. RESULTS: The assay imprecision was <5.3 %. Assay linearity ranged from 13.7 to 1923.3 pmol/L. The LLoQ corresponding to a CV of 20 % was determined to be 8.9 pmol/L. Bland-Altman analysis revealed a mean bias of 29.3 pmol/L or 9.1 % between our LC-MS/MS E2 assay and an external reference laboratory measuring E2 by LC-MS/MS. CONCLUSIONS: Our LC-MS/MS E2 assay shows acceptable accuracy, precision, functional sensitivity (LLoQ), and linearity for E2 quantification. Our LC-MS/MS E2 assay also showed good agreement with an external reference laboratory measuring E2 by LC-MS/MS. In addition, using CALIPER samples, we established robust age- and sex-specific pediatric E2 reference intervals to improve accuracy of test result interpretation and clinical decision making.


Assuntos
Estrona , Espectrometria de Massas em Tandem , Masculino , Feminino , Humanos , Criança , Adolescente , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida/métodos , Estradiol
14.
J Clin Lab Anal ; 37(23-24): e24995, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38087776

RESUMO

BACKGROUND: The reference intervals (RIs) for liver function tests (LFTs) were determined in Iranian children for the first time. METHODS: A total of 344 healthy pediatrics aged 3 days to 30 months old were recruited. Serum levels of ALT, AST, ALP, direct bilirubin, and total bilirubin were measured. RIs were determined using CLSI Ep28-A3 guidelines. RESULTS: All analytes demonstrated age-specific differences except AST. ALT and ALP demonstrated significantly elevated levels in infants 0 to <5 months relative to the remainder of the age range. Direct and total bilirubin demonstrated markedly elevated levels in early life with mean of 0.28 mg/dL and 1.64 mg/dL observed for direct and total bilirubin, respectively, decreasing by ~50% in the adjacent partition. CONCLUSION: These novel data will help improve the clinical interpretation of biochemical test results in young Iranian neonates and children and can be of value to clinical laboratories with similar populations.


Assuntos
Bilirrubina , Lactente , Recém-Nascido , Humanos , Criança , Pré-Escolar , Testes de Função Hepática , Irã (Geográfico) , Valores de Referência , Fatores Etários
15.
Crit Rev Clin Lab Sci ; 59(2): 76-92, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34587857

RESUMO

Diagnosis, prognostication, and monitoring of maternal health throughout pregnancy relies on laboratory testing, including but not limited to key markers of thyroid, hepatic, cardiac, hematology, and renal function. Dynamic physiological processes during gestation significantly influence the maternal biochemistry that supports both the mother and fetus. Resultant changes in blood biochemistry alter the expected values of common laboratory tests. However, the importance of pregnancy-specific reference intervals for laboratory test result interpretation and appropriate monitoring of maternal health and complications is underappreciated. Most clinical laboratories continue to use non-pregnant adult reference intervals for laboratory test interpretation in pregnancy. The current review summarizes and critically evaluates the available literature regarding physiological and metabolic adaptations in pregnancy and their influence on common biomarkers of health and disease. The main laboratory parameters discussed include thyroid, hepatic, metabolic, renal, hematology, inflammatory, and cardiac markers. Considering the available data, further studies are urgently needed to establish trimester-specific reference intervals in healthy pregnant women on updated analytical platforms. Without such data, the standard of clinical laboratory service in pregnancy remains compromised and affects the quality of maternal-fetal healthcare.


Assuntos
Saúde Materna , Glândula Tireoide , Adulto , Biomarcadores , Feminino , Humanos , Gravidez , Valores de Referência , Glândula Tireoide/fisiologia
16.
Allergy ; 77(9): 2665-2676, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35396721

RESUMO

BACKGROUND: There is limited ability to predict the severity of allergic reactions in children. Data derived predominantly from adults have implicated the platelet-activating factor pathway as a potential contributor to severe anaphylaxis. In this study, we sought to prospectively assess involvement of key components of the platelet-activating factor pathway in pediatric patients with anaphylaxis. METHODS: Forty-six pediatric patients (<18 years) presenting with acute anaphylaxis were assessed. Anaphylaxis severity was graded and serum anaphylaxis markers were measured acutely and in 36 children who returned for follow-up >4 weeks after their acute presentation. These markers were compared with pediatric laboratory reference sera. RESULTS: Severe anaphylaxis was experienced by 12/46 (26%) and mild-moderate anaphylaxis in 34/46 (74%) children. Platelet-activating factor acetylhydrolase (PAF-AH) activity was inversely associated with severe anaphylaxis: 9/12 children with severe anaphylaxis had reduced PAF-AH activity as compared with 14/34 with mild-moderate anaphylaxis (p < .05). Furthermore, 3/3 children who required intensive care had markedly reduced mean PAF-AH (nmol/ml/min) (13.73, 95%CI: 7.42-20.03) versus 20/23 who required ward/emergency department care (17.81, 95%CI: 16.80-18.83; p < .05). In children with anaphylaxis, PAF-AH during acute anaphylaxis was unchanged relative to the child's basal levels (mean, 17.26, 95%CI: 16.10-18.42 vs 17.50, 95%CI: 16.21-18.78, p = .63) and was lower than healthy pediatric controls (mean 19.21; 95%CI:18.21-20.21; p < .05). CONCLUSION: Decreased serum PAF-AH activity is a biomarker of severe anaphylaxis. Levels of this enzyme do not change from basal levels during acute anaphylaxis. Our results show that PAF-AH is a biomarker of anaphylaxis severity in children. This key regulatory enzyme may modulate susceptibility to severe anaphylaxis.


Assuntos
1-Alquil-2-acetilglicerofosfocolina Esterase , Anafilaxia , Adulto , Anafilaxia/diagnóstico , Anafilaxia/etiologia , Biomarcadores , Criança , Humanos , Fator de Ativação de Plaquetas/metabolismo
17.
Clin Chem Lab Med ; 60(5): 655-661, 2022 04 26.
Artigo em Inglês | MEDLINE | ID: mdl-35114742

RESUMO

OBJECTIVES: Among the diagnostic tests that have recently become commercially available for diagnosing coronavirus disease 2019 (COVID-19), the fully-automated Roche Elecsys severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antigen electrochemiluminescence immunoassay (ECLIA) is one of the most widespread for its adaptability within a system of laboratory automation, rapidity and high-throughput. This article is aimed to provide the results of the first pooled analysis of its accuracy for diagnosing SARS-CoV-2 infections. CONTENT: We carried out an electronic search in Scopus and Medline, without language or date restrictions (i.e., up to January 18, 2022), to identify articles where the diagnostic performance of Roche Elecsys SARS-CoV-2 antigen ECLIA was compared with that of reference molecular diagnostic techniques. SUMMARY: Overall, 11 studies were identified, 10 of which (n=6,095 swabs) provided necessary data for inclusion in a pooled analysis. The pooled diagnostic sensitivity, specificity and area under the curve (AUC) in nasopharyngeal samples were 0.68 (95%CI, 0.66-0.70), 0.99 (95%CI, 0.99-0.99) and 0.958 (95%CI, 0.936-0.980), respectively. The cumulative observed agreement with reference molecular assays was 89.5% and the kappa statistic was 0.735 (95%CI, 0.716-0.754). The pooled diagnostic sensitivity in samples with high viral load (i.e., cycle threshold values <28-30) was 0.95 (95%CI, 0.92-0.97). OUTLOOK: The results of this pooled analysis confirm that the fully-automated Roche Elecsys SARS-CoV-2 antigen ECLIA has high diagnostic specificity and optimal diagnostic sensitivity for identifying nasopharyngeal samples with higher viral load, thus making it a reliable technique for mass screening and for supporting strategies based on shorten isolation and/or quarantine.


Assuntos
COVID-19 , SARS-CoV-2 , Anticorpos Antivirais , COVID-19/diagnóstico , Humanos , Imunoensaio/métodos , Sensibilidade e Especificidade , Testes Sorológicos
18.
Clin Chem Lab Med ; 60(11): 1839-1846, 2022 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-36117138

RESUMO

OBJECTIVES: The objective of this study was to establish pediatric reference limits for autoimmune disease markers in the Canadian Laboratory Initiative on Pediatric Reference Intervals (CALIPER) cohort of healthy children and adolescents to support their interpretation and clinical decision making. The CALIPER is a national study of healthy children aiming to close gaps in pediatric laboratory medicine by establishing a robust database of pediatric reference intervals for pediatric disease biomarkers (caliperdatabase.org). METHODS: Healthy children and adolescents (n=123, aged 1-19) were recruited to CALIPER with informed consent. Serum autoantibody testing conducted on the BIO-FLASH analyzer (Werfen, Barcelona, Spain) included anti-dsDNA IgG, anti-Sm IgG, anti-RNP IgG, anti-SSB/La IgG, anti-Ro60 IgG, anti-Ro52 IgG, anti-cardiolipin IgG, anti-MPO IgG, anti-PR3 IgG, and anti-tTG IgA. Pediatric reference limits representing 95th, 97.5th, and 99th percentiles were calculated using the non-parametric rank method according to Clinical Laboratory Standards Institute C28-A3 guidelines. RESULTS: The proportion of samples with results above the lower limit of the analytical measuring range were: anti-cardiolipin IgG 90%, anti-dsDNA 22%, anti-Sm 13%, anti-RNP 0.8%, anti-SSB/La 0%, anti-Ro60 0%, anti-Ro52 0%, anti-MPO 25%, anti-PR3 9%, and anti-tTG IgA 28%. Pediatric reference limits and associated 90% confidence intervals were established for all 10 markers. All autoantibodies could be described by one age range except for anti-cardiolipin IgG and anti-MPO. A sex-specific difference was identified for anti-tTG IgA. CONCLUSIONS: Robust pediatric reference limits for 10 commonly clinically utilized autoimmune markers established herein will allow for improved laboratory assessment and clinical decision making in pediatric patients using the BIO-FLASH assay platform worldwide.


Assuntos
Autoanticorpos , Imunoglobulina G , Adolescente , Biomarcadores , Criança , Feminino , Humanos , Imunoglobulina A , Masculino , Valores de Referência
19.
Biotechnol Appl Biochem ; 69(3): 1300-1310, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34028875

RESUMO

INTRODUCTION: We aimed to define specific reference intervals (RIs) for 11 biomarkers including inflammatory and oxidative stress biomarkers, liver, and renal function tests in a healthy Iranian adult population for the first time. METHODS: CLSI Ep28-A3 guidelines were then used to calculate accurate age- and sex- as well as body mass index (BMI)-specific RIs. RESULTS: RIs for studied biomarkers showed no significant age and sex-specific differences, except for uric acid, which had higher concentrations in men when compared to women. Additionally, after partitioning the participants based on the BMI with a cutoff point of 25 kg/m2 , only the levels of hs-CRP were positively associated with higher BMI (RI for BMI>25: 0.51-7.85 mg/L and for BMI<25: 0.40-4.46 mg/L). RI for PAB and anti-hsp-27 were reported 4.69-155.36 HK and 0.01-0.70 OD in men and women aged 35-65 years old. CONCLUSION: Partitioning by sex and BMI was only required for uric acid and hs-CRP, respectively, while other biomarkers required no partitioning. These results can be expected to valuably contribute to improve laboratory test result interpretation in adults for improved monitoring of various diseases in the Iranian population.


Assuntos
Antioxidantes , Proteína C-Reativa , Adulto , Idoso , Antioxidantes/metabolismo , Biomarcadores , Proteína C-Reativa/metabolismo , Feminino , Proteínas de Choque Térmico HSP27 , Humanos , Irã (Geográfico) , Masculino , Pessoa de Meia-Idade , Espécies Reativas de Oxigênio/metabolismo , Ácido Úrico
20.
Physiology (Bethesda) ; 35(5): 288-301, 2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-32783610

RESUMO

The global epidemiology of coronavirus disease 2019 (COVID-19) suggests a wide spectrum of clinical severity, ranging from asymptomatic to fatal. Although the clinical and laboratory characteristics of COVID-19 patients have been well characterized, the pathophysiological mechanisms underlying disease severity and progression remain unclear. This review highlights key mechanisms that have been proposed to contribute to COVID-19 progression from viral entry to multisystem organ failure, as well as the central role of the immune response in successful viral clearance or progression to death.


Assuntos
Betacoronavirus/patogenicidade , Infecções por Coronavirus/fisiopatologia , Infecções por Coronavirus/virologia , Pneumonia Viral/fisiopatologia , Pneumonia Viral/virologia , COVID-19 , Citocinas/metabolismo , Progressão da Doença , Humanos , Pandemias , SARS-CoV-2
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA