Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Tipo de documento
País/Região como assunto
Ano de publicação
Intervalo de ano de publicação
1.
Clin Physiol Funct Imaging ; 36(2): 146-54, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25348641

RESUMO

Assessment of image analysis methods and computer software used in (99m) Tc-MAG3 dynamic renography is important to ensure reliable study results and ultimately the best possible care for patients. In this work, we present a national multicentre study of the quantification accuracy in (99m) Tc-MAG3 renography, utilizing virtual dynamic scintigraphic data obtained by Monte Carlo-simulated scintillation camera imaging of digital phantoms with time-varying activity distributions. Three digital phantom studies were distributed to the participating departments, and quantitative evaluation was performed with standard clinical software according to local routines. The differential renal function (DRF) and time to maximum renal activity (Tmax ) were reported by 21 of the 28 Swedish departments performing (99m) Tc-MAG3 studies as of 2012. The reported DRF estimates showed a significantly lower precision for the phantom with impaired renal uptake than for the phantom with normal uptake. The Tmax estimates showed a similar trend, but the difference was only significant for the right kidney. There was a significant bias in the measured DRF for all phantoms caused by different positions of the left and right kidney in the anterior-posterior direction. In conclusion, this study shows that virtual scintigraphic studies are applicable for quality assurance and that there is a considerable uncertainty associated with standard quantitative parameters in dynamic (99m) Tc-MAG3 renography, especially for patients with impaired renal function.


Assuntos
Nefropatias/diagnóstico por imagem , Rim/diagnóstico por imagem , Renografia por Radioisótopo/métodos , Compostos Radiofarmacêuticos/administração & dosagem , Tecnécio Tc 99m Mertiatida/administração & dosagem , Simulação por Computador , Estudos de Viabilidade , Feminino , Câmaras gama , Humanos , Interpretação de Imagem Assistida por Computador , Rim/fisiopatologia , Nefropatias/fisiopatologia , Masculino , Método de Monte Carlo , Variações Dependentes do Observador , Imagens de Fantasmas , Valor Preditivo dos Testes , Renografia por Radioisótopo/instrumentação , Renografia por Radioisótopo/normas , Reprodutibilidade dos Testes , Software , Suécia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA