Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Sci Rep ; 13(1): 10338, 2023 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-37365253

RESUMO

Dynamic phase-only beam shaping with a liquid crystal spatial light modulator is a powerful technique for tailoring the intensity profile or wave front of a beam. While shaping and controlling the light field is a highly researched topic, dynamic nonlinear beam shaping has hardly been explored so far. One potential reason is that generating the second harmonic is a degenerate process as it mixes two fields at the same frequency. To overcome this problem, we propose the use of type II phase matching as a control mechanism to distinguish between the two fields. Our experiments demonstrate that distributions of arbitrary intensity can be shaped in the frequency-converted field at the same quality as for linear beam shaping and with conversion efficiencies similar to without beam shaping. We envision this method as a milestone toward beam shaping beyond the physical limits of liquid crystal displays by facilitating dynamic phase-only beam shaping in the ultraviolet spectral range.

2.
J Mol Biol ; 433(13): 166964, 2021 06 25.
Artigo em Inglês | MEDLINE | ID: mdl-33781758

RESUMO

Recent years have seen a dramatic improvement in protein-design methodology. Nevertheless, most methods demand expert intervention, limiting their widespread adoption. By contrast, the PROSS algorithm for improving protein stability and heterologous expression levels has been successfully applied to a range of challenging enzymes and binding proteins. Here, we benchmark the application of PROSS as a stand-alone tool for protein scientists with no or limited experience in modeling. Twelve laboratories from the Protein Production and Purification Partnership in Europe (P4EU) challenged the PROSS algorithm with 14 unrelated protein targets without support from the PROSS developers. For each target, up to six designs were evaluated for expression levels and in some cases, for thermal stability and activity. In nine targets, designs exhibited increased heterologous expression levels either in prokaryotic and/or eukaryotic expression systems under experimental conditions that were tailored for each target protein. Furthermore, we observed increased thermal stability in nine of ten tested targets. In two prime examples, the human Stem Cell Factor (hSCF) and human Cadherin-Like Domain (CLD12) from the RET receptor, the wild type proteins were not expressible as soluble proteins in E. coli, yet the PROSS designs exhibited high expression levels in E. coli and HEK293 cells, respectively, and improved thermal stability. We conclude that PROSS may improve stability and expressibility in diverse cases, and that improvement typically requires target-specific expression conditions. This study demonstrates the strengths of community-wide efforts to probe the generality of new methods and recommends areas for future research to advance practically useful algorithms for protein science.


Assuntos
Algoritmos , Estabilidade Proteica , Animais , Escherichia coli/metabolismo , Células HEK293 , Ensaios de Triagem em Larga Escala , Humanos , Modelos Moleculares , Proteínas/química , Proteínas/metabolismo , Solubilidade , Temperatura , Peixe-Zebra
3.
J Bone Joint Surg Am ; 86(10): 2257-62, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15466736

RESUMO

BACKGROUND: Range of motion is a crucial measure of outcome after total knee arthroplasty. In order for maximum flexion to occur, the femur must progressively shift posteriorly on the tibia, a movement that is known as femoral rollback. Mobile bearings with free anterior-posterior translation could improve knee flexion by allowing such motion. The purpose of the present study was to determine the influence of an anterior-posterior gliding mobile bearing on the postoperative range of knee motion in patients with an intact posterior cruciate ligament. METHODS: We performed a prospective, randomized clinical trial of fifty consecutive total knee arthroplasties that were performed with use of the LCS-Universal prosthesis. Participants were randomized to receive either a deep-dish rotating platform or a mobile bearing that allowed additional anterior-posterior translation, the latter of which requires an intact posterior cruciate ligament. The ranges of motion of the knees were assessed to detect a 15 degrees difference in the active non-weight-bearing range of motion with a power (1 - beta) of 20% and with the level of significance (alpha) set at 0.05. The translation of the mobile bearing was measured with use of a standardized ultrasound technique and was correlated with maximum knee flexion. The participants and the assessor were blinded throughout the study. RESULTS: At the time of the one-year follow-up evaluation, forty-eight knees were available for an intention-to-treat analysis. The mean active non-weight-bearing range of motion at one year was 113 degrees (95% confidence interval, 108 degrees to 118 degrees ) in the twenty-six knees that had received a rotating platform and 111 degrees (95% confidence interval, 115 degrees to 125 degrees ) in the twenty-two knees that had received an anterior-posterior gliding bearing (p = 0.57). In the latter group, a continuous rollback occurred in two knees. There was no significant correlation between knee flexion and anterior-posterior translation (r(2) = 0.015). CONCLUSIONS: The use of a mobile bearing that allowed free anterior-posterior translation did not regularly restore femoral rollback and did not improve range of motion after total knee arthroplasty compared with the findings seen in association with the use of a rotating platform.


Assuntos
Artroplastia do Joelho/métodos , Prótese do Joelho , Amplitude de Movimento Articular , Adulto , Idoso , Idoso de 80 Anos ou mais , Método Duplo-Cego , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Estatísticas não Paramétricas
4.
J Bone Joint Surg Am ; 85(7): 1204-8, 2003 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12851343

RESUMO

BACKGROUND: Although surgery for the treatment of hallux valgus is frequently performed, the exact rate of deep vein thrombosis following this procedure is unknown. We performed a single-center, prospective, phlebographically controlled study to quantify the rate of venous thrombosis following operative correction of hallux valgus. METHODS: Consecutive patients undergoing chevron bunionectomy for correction of hallux valgus deformity were enrolled in the study. Patients with clinical or hematological risk factors for venous thrombosis were excluded. One hundred patients with a mean age of 48.9 years were operated on and did not receive medical prophylaxis against thrombosis. All patients were assessed with phlebography at a mean of twenty-nine days postoperatively. RESULTS: Venous thrombosis was found in four patients (4%). The mean age of these patients (and standard deviation) was 61.7 +/- 6.1 years compared with a mean age of 48.4 +/- 13.9 years for the patients in whom thrombosis did not develop (p = 0.034). CONCLUSIONS: Patients are at a low risk for venous thrombosis following surgical treatment of hallux valgus. The need for prophylaxis against thrombosis should be calculated individually for each patient according to his or her known level of risk. Routine medical prophylaxis against thrombosis might be justified for patients over the age of sixty years.


Assuntos
Hallux Valgus/cirurgia , Osteotomia/efeitos adversos , Trombose Venosa/etiologia , Distribuição por Idade , Idoso , Índice de Massa Corporal , Feminino , Humanos , Tempo de Internação/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Osteotomia/métodos , Tempo de Tromboplastina Parcial , Seleção de Pacientes , Flebografia , Prevalência , Prognóstico , Estudos Prospectivos , Tempo de Protrombina , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Trombose Venosa/diagnóstico por imagem , Trombose Venosa/epidemiologia , Trombose Venosa/prevenção & controle
5.
Clin Orthop Relat Res ; (421): 169-74, 2004 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15123943

RESUMO

After anterior cruciate ligament-sacrificing total knee replacement, mobile bearings sometimes have paradoxic movement but the implications of such movement on function, wear, and implant survival are not known. To study this potential problem accurate, reliable, and widely available inexpensive tools for in vivo mobile-bearing motion analyses are needed. We developed a method using an 8-MHz ultrasound to analyze mobile-bearing motion and ascertained accuracy, precision, and reliability compared with plain and standard digital radiographs. The anterior rim of the mobile bearing was the target for all methods. The radiographs were taken in a horizontal plane at neutral rotation and incremental external and internal rotations. Five investigators examined four positions of the mobile bearing with all three methods. The accuracy and precision were: ultrasound, 0.7 mm and 0.2 mm; digital radiograph, 0.4 mm and 0.2 mm; and plain radiographs, 0.7 mm and 0.3 mm. The interrater and intrarater reliability ranged between 0.3 to 0.4 mm and 0.1 to 0.2 mm, respectively. The difference between the methods was not significant for neutral rotation but ultrasound was significantly more accurate than any one degree of rotation or higher. Ultrasound of 8 MHz provides an accuracy and reliability that is suitable for evaluation of in vivo meniscal bearing motion. Whether this method or others are sufficiently accurate to detect motion leading to abnormal wear is not known.


Assuntos
Artroplastia do Joelho , Meniscos Tibiais/diagnóstico por imagem , Meniscos Tibiais/fisiopatologia , Seguimentos , Humanos , Modelos Biológicos , Movimento/fisiologia , Intensificação de Imagem Radiográfica , Reprodutibilidade dos Testes , Ultrassonografia/métodos , Suporte de Carga/fisiologia
6.
Breast J ; 8(5): 320-2, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12199765

RESUMO

A case of radiation-induced sarcoma of the chest wall is reported. Twenty-seven years 11 months after orthovoltage radiotherapy of the right breast a 69-year-old woman developed a radiation-induced osteosarcoma of the right thoracic wall. Initial diagnosis has been T-cell lymphoma of the skin. The right breast was irradiated with tangential fields and a total dose of 40 Gy, 2 Gy/day, 5 days a week. Orthovoltage treatment was performed in two courses of 20 Gy, 3 months apart. The clinical appearance of the secondary sarcoma was a diffuse infiltrated area in the irradiated breast which seemed to be fixed to the chest wall. Magnetic resonance imaging (MRI) demonstrated a mass in the right anterior thoracic wall which destroyed the fourth to the sixth rib. The tumor infiltrated the thoracic wall, including subcutaneous tissue and pericardium, as well as extending into the subphrenic space. Biopsy of the lesion revealed a poorly differentiated osteosarcoma. The patient's general condition precluded surgical or chemotherapeutic intervention; she died due to a cerebral stroke 6 months later. This case fulfilled all criteria for radiation-induced sarcoma, as there was a prior history of radiotherapy, latency period of several years, development of sarcoma within the irradiated field, and histologic confirmation of sarcoma.


Assuntos
Neoplasias Ósseas/diagnóstico , Neoplasias da Mama/radioterapia , Linfoma de Células T/radioterapia , Neoplasias Induzidas por Radiação/diagnóstico , Osteossarcoma/diagnóstico , Idoso , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/patologia , Diagnóstico Diferencial , Evolução Fatal , Feminino , Humanos , Imageamento por Ressonância Magnética , Neoplasias Induzidas por Radiação/diagnóstico por imagem , Neoplasias Induzidas por Radiação/patologia , Osteossarcoma/diagnóstico por imagem , Osteossarcoma/patologia , Cintilografia , Parede Torácica , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA