Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Sensors (Basel) ; 16(7)2016 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-27455276

RESUMO

For many diseases, where a particular organ is affected, chemical by-products can be found in the patient's exhaled breath. Breath analysis is often done using gas chromatography and mass spectrometry, but interpretation of results is difficult and time-consuming. We performed characterization of patients' exhaled breath samples by an electronic nose technique based on an array of nanomechanical membrane sensors. Each membrane is coated with a different thin polymer layer. By pumping the exhaled breath into a measurement chamber, volatile organic compounds present in patients' breath diffuse into the polymer layers and deform the membranes by changes in surface stress. The bending of the membranes is measured piezoresistively and the signals are converted into voltages. The sensor deflection pattern allows one to characterize the condition of the patient. In a clinical pilot study, we investigated breath samples from head and neck cancer patients and healthy control persons. Evaluation using principal component analysis (PCA) allowed a clear distinction between the two groups. As head and neck cancer can be completely removed by surgery, the breath of cured patients was investigated after surgery again and the results were similar to those of the healthy control group, indicating that surgery was successful.


Assuntos
Técnicas Biossensoriais/métodos , Neoplasias de Cabeça e Pescoço/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Testes Respiratórios , Feminino , Neoplasias de Cabeça e Pescoço/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Análise de Componente Principal
2.
Langmuir ; 29(24): 7551-6, 2013 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-23742183

RESUMO

With their capability for real-time and label-free detection of targets ranging from gases to biological molecules, nanomechanical sensors are expected to contribute to various fields, such as medicine, security, and environmental science. For practical applications, one of the major issues of nanomechanical sensors is the difficulty of coating receptor layers on their surfaces to which target molecules adsorb or react. To have measurable deflection, a single-side coating is commonly applied to cantilever-type geometry, and it requires specific methods or protocols, such as inkjet spotting or gold-thiol chemistry. If we can apply a double-side coating to nanomechanical sensors, it allows almost any kind of coating technique including dip coating methods, making nanomechanical sensors more useful with better user experiences. Here we address the feasibility of the double-side coating on nanomechanical sensors demonstrated by a membrane-type surface stress sensor (MSS) and verify its working principle by both finite element analysis (FEA) and experiments. In addition, simple hand-operated dip coating is demonstrated as a proof of concept, achieving practical receptor layers without any complex instrumentation. Because the double-side coating is compatible with batch protocols such as dip coating, double-side-coated MSS represents a new paradigm of one-chip-one-channel (channels on a chip are all coated with the same receptor layers) shifting from the conventional one-chip-multiple-channel (channels on a chip are coated with different receptor layers) paradigm.


Assuntos
Membranas Artificiais , Nanoestruturas , Análise de Elementos Finitos , Propriedades de Superfície
3.
Nanotechnology ; 24(23): 235302, 2013 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-23676659

RESUMO

We report on the successful development of a well-controlled two-step batch nano-fabrication process to achieve nanometer-size gaps at the wafer scale. The technique is based on an optimized electron-beam lithography process, which enables the fabrication of nanogaps in the range (15 ± 4) nm. Following this first step, the feedback-controlled electrochemical deposition of gold from an aqueous HAuCl4-based electrolyte is applied to further reduce the size of the gap down to about 0.3-1.0 nm. This protocol was successfully demonstrated by fabricating more than 385 nanogaps on a 4 inch wafer. The reproducible fabrication of nanogaps in the range between 0.3 and 1.0 nm opens up new perspectives for addressing the electrical and reactivity properties of single molecules and clusters in confined space under well-controlled conditions.

4.
Sensors (Basel) ; 12(11): 15873-87, 2012 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-23202237

RESUMO

We present a new generation of piezoresistive nanomechanical Membrane-type Surface stress Sensor (MSS) chips, which consist of a two dimensional array of MSS on a single chip. The implementation of several optimization techniques in the design and microfabrication improved the piezoresistive sensitivity by 3~4 times compared to the first generation MSS chip, resulting in a sensitivity about ~100 times better than a standard cantilever-type sensor and a few times better than optical read-out methods in terms of experimental signal-to-noise ratio. Since the integrated piezoresistive read-out of the MSS can meet practical requirements, such as compactness and not requiring bulky and expensive peripheral devices, the MSS is a promising transducer for nanomechanical sensing in the rapidly growing application fields in medicine, biology, security, and the environment. Specifically, its system compactness due to the integrated piezoresistive sensing makes the MSS concept attractive for the instruments used in mobile applications. In addition, the MSS can operate in opaque liquids, such as blood, where optical read-out techniques cannot be applied.

5.
Nano Lett ; 11(3): 1044-8, 2011 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-21314159

RESUMO

Nanomechanical cantilever sensors have been emerging as a key device for real-time and label-free detection of various analytes ranging from gaseous to biological molecules. The major sensing principle is based on the analyte-induced surface stress, which makes a cantilever bend. In this letter, we present a membrane-type surface stress sensor (MSS), which is based on the piezoresistive read-out integrated in the sensor chip. The MSS is not a simple "cantilever," rather it consists of an "adsorbate membrane" suspended by four piezoresistive "sensing beams," composing a full Wheatstone bridge. The whole analyte-induced isotropic surface stress on the membrane is efficiently transduced to the piezoresistive beams as an amplified uniaxial stress. Evaluation of a prototype MSS used in the present experiments demonstrates a high sensitivity which is comparable with that of optical methods and a factor of more than 20 higher than that obtained with a standard piezoresistive cantilever. The finite element analyses indicate that changing dimensions of the membrane and beams can substantially increase the sensitivity further. Given the various conveniences and advantages of the integrated piezoresistive read-out, this platform is expected to open a new era of surface stress-based sensing.

6.
Nanotechnology ; 20(1): 015501, 2009 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-19417252

RESUMO

The performance of microfabricated piezoresistive cantilever array sensors has been evaluated using various vapors of volatile organic compounds including alkanes with different chain length from 5 (n-pentane) to 14 (n-tetradecane). We demonstrate that piezoresistive microcantilever array sensors have the selectivity of discriminating individual alkanes in a homologous series as well as common volatile organic compounds according to principal component analysis. We developed a new method to evaluate the sensitivity, taking advantage of the low vapor pressures of alkanes with longer chains, such as n-dodecane, n-tridecane and n-tetradecane, under saturated vapor conditions. This method reveals sub-ppm sensitivity and the cantilever response is found to follow the mass of evaporated analytes as calculated using a quantitative model based on the Langmuir evaporation model.

7.
Arch Histol Cytol ; 72(4-5): 251-9, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-21471660

RESUMO

We have recently demonstrated that indentation-type atomic force microscopy (IT-AFM) is capable of detecting early onset osteoarthritis (OA) (Stolz, 2009). This study was based on biopsies, using a desk-top commercial atomic force microscope (AFM). However, cartilage analysis in the knee joints needs to be non-destructive to avoid new seeding points for OA by the taking of biopsies. This requires bringing the probe tip in contact with the articular cartilage (AC) surface inside the joint. Here we present our recent progress towards a medical instrument for performing such IT-AFM measurements for in-vivo knee diagnostics. The scanning force arthroscope (SFA) integrates a miniaturized AFM into a standard arthroscopic sleeve, and is used for direct, quantitative, in situ inspection of AC (Imer et al., 2006). The stabilization and the positioning of the instrument relative to the surface under investigation were performed by means of eight inflatable balloons. An integrated three-dimensional, piezoelectric scanner allowed raster scanning and probing of a small area of cartilage around the point of insertion. An AFM probe with an integrated deflection sensor was mounted at the distal end of the instrument. Using this instrument, several measurements were performed on agarose gel and on porcine cartilage samples. The load-displacement curves obtained were analyzed and the dynamic elastic moduli | E(*) | were calculated. A good correlation between these values and those published in the scientific literature was found. Therefore, we concluded that the SFA can provide quantitative measurements to detect early pathological changes in OA.


Assuntos
Cartilagem Articular/fisiologia , Cartilagem Articular/ultraestrutura , Microscopia de Força Atômica/métodos , Animais , Artroscopia/métodos , Fenômenos Biomecânicos/fisiologia , Osteoartrite/patologia , Estresse Mecânico , Suínos
8.
Rev Sci Instrum ; 81(6): 063706, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20590245

RESUMO

The quartz tuning fork based probe {e.g., Akiyama et al. [Appl. Surf. Sci. 210, 18 (2003)]}, termed "A-Probe," is a self-sensing and self-actuating (exciting) probe for dynamic mode atomic force microscope (AFM) operation. It is an oscillatory force sensor consisting of the two discrete resonators. This paper presents the investigations on an improved A-Probe: its batch fabrication and assembly, mounting on an AFM head, electrical setup, characterization, and AFM imaging. The fundamental features of the A-Probe are electrically and optically characterized in "approach-withdraw" experiments. Further investigations include the frequency response of an A-Probe to small mechanical vibrations externally applied to the tip and the effective loading force yielding between the tip and the sample during the periodic contact. Imaging of an electronic chip, a compact disk stamper, carbon nanotubes, and Si beads is demonstrated with this probe at ambient conditions in the so-called frequency modulation mode. A special probe substrate, which can snap on a receptacle fixed on an AFM head, and a special holder including a preamplifier electronic are introduced. We hope that the implementation and characterization of the A-Probe described in this paper will provide hints for new scanning probe techniques.

9.
Nanotechnology ; 19(38): 384004, 2008 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-21832564

RESUMO

Four different conductive supports are analysed regarding their suitability for combined atomic force and scanning electrochemical microscopy (AFM-SECM) on biological membranes. Highly oriented pyrolytic graphite (HOPG), MoS(2), template stripped gold, and template stripped platinum are compared as supports for high resolution imaging of reconstituted membrane proteins or native membranes, and as electrodes for transferring electrons from or to a redox molecule. We demonstrate that high resolution topographs of the bacterial outer membrane protein F can be recorded by contact mode AFM on all four supports. Electrochemical feedback experiments with conductive cantilevers that feature nanometre-scale electrodes showed fast re-oxidation of the redox couple Ru(NH(3))(6)(3+/2+) with the two metal supports after prolonged immersion in electrolyte. In contrast, the re-oxidation rates decayed quickly to unpractical levels with HOPG or MoS(2) under physiological conditions. On HOPG we observed heterogeneity in the re-oxidation rate of the redox molecules with higher feedback currents at step edges. The latter results demonstrate the capability of conductive cantilevers with small electrodes to measure minor variations in an SECM signal and to relate them to nanometre-scale features in a simultaneously recorded AFM topography. Rapid decay of re-oxidation rate and surface heterogeneity make HOPG or MoS(2) less attractive for combined AFM-SECM experiments on biological membranes than template stripped gold or platinum supports.

10.
Anal Chem ; 78(15): 5436-42, 2006 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-16878880

RESUMO

A combined atomic force and scanning electrochemical microscope probe is presented. The probe is electrically insulated except at the very apex of the tip, which has a radius of curvature in the range of 10-15 nm. Steady-state cyclic voltammetry measurements for the reduction of Ru(NH3)6Cl3 and feedback experiments showed a distinct and reproducible response of the electrode. These experimental results agreed with finite element simulations for the corresponding diffusion process. Sequentially topographical and electrochemical studies of Pt lines deposited onto Si3N4 and spaced 100 nm apart (edge to edge) showed a lateral electrochemical resolution of 10 nm.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA