Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Ano de publicação
Intervalo de ano de publicação
1.
Radiology ; 305(2): 353-361, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35819322

RESUMO

Background US tools to quantify liver fat content have recently been made clinically available by different vendors, but comparative data on their accuracy are lacking. Purpose To compare the diagnostic performances of the attenuation parameters of US machines from three different manufacturers (vendors 1, 2, and 3) in participants who underwent liver fat quantification with the MRI-derived proton density fat fraction (PDFF). Materials and Methods From July 2020 to June 2021, consecutive participants with chronic liver disease were enrolled in this prospective single-center study and underwent MRI PDFF quantification (reference standard) and US on the same day. US was performed with two different machines from among three vendors assessed. Areas under the receiver operating characteristic curve (AUCs) for the staging of liver steatosis (MRI PDFF: ≥5.5% for grade ≥S1 and ≥15.5% for grade ≥S2) were calculated in test and validation samples and then compared between vendors in the study sample. Results A total of 534 participants (mean age, 60 years ± 13 [SD]; 320 men) were evaluated. Failure of measurements occurred in less than 1% of participants for all vendors. Correlation coefficients with the MRI PDFF were 0.71, 0.73, and 0.54 for the attenuation coefficients of vendors 1, 2, and 3, respectively. In the test sample, AUCs for diagnosis of steatosis grade S1 and higher and grade S2 and higher were 0.89 and 0.93 for vendor 1 attenuation, 0.88 and 0.92 for vendor 2 attenuation, and 0.79 and 0.79 for vendor 3 attenuation, respectively. In the validation sample, a threshold value of 0.65 for vendor 1 and 0.66 for vendor 2 yielded sensitivity of 77% and 84% and specificity of 78% and 85%, respectively, for diagnosis of grade S1 and higher. Vendor 2 attenuation had greater AUCs than vendor 3 attenuation (P = .001 and P = .003) for diagnosis of grade S1 and higher and grade S2 and higher, respectively, and vender 2 had greater AUCs for attenuation than vendor 1 for diagnosis of grade S2 and higher (P = .04). For all vendors, attenuation was not associated with liver stiffness (correlation coefficients <0.05). Conclusion To stage liver steatosis, attenuation coefficient accuracy varied among US devices across vendors when using MRI proton density fat fraction quantification as the reference standard, with some demonstrating excellent diagnostic performance and similar cutoff values. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Dubinsky in this issue.


Assuntos
Fígado Gorduroso , Hepatopatia Gordurosa não Alcoólica , Masculino , Humanos , Pessoa de Meia-Idade , Prótons , Fígado Gorduroso/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Fígado/diagnóstico por imagem , Tecido Adiposo/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem
2.
Eur Radiol ; 30(2): 1088-1095, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31612247

RESUMO

OBJECTIVES: To assess the learning curve for performing reliable liver stiffness measurements using a new hybrid machine composed of transient elastography (TE) interfaced with an ultrasound device for radiographers and radiologists with different levels of expertise in ultrasound imaging. METHODS: Ten novice operators who had never performed TE measurements were prospectively evaluated from April to October 2018: senior radiologists, young radiologists, fellows, radiographers, and residents, with different levels of experience in abdominal ultrasound imaging. All operators had a short theoretical training followed by a training session under supervision in three patients. Then, each operator had to perform TE in 50 consecutive patients with chronic liver disease, using beforehand ultrasound examination to select measurement area in the right liver lobe, and if needed, the XL probe. Percentages of failures and reliable measurements were compared. RESULTS: The rates of failures of measurements, poorly reliable, reliable, and very reliable results, were of 4.2% (21/500), 2.4% (12/500), 47.6% (238/500), and 45.8% (229/500), respectively. The rates of reliable plus very reliable results were excellent, ranging from 91 to 96% among all the subgroups. The rates of very reliable, reliable, and unreliable results did not differ between operator subgroups and especially between junior radiologists, senior radiologists, and radiographers. No breaking point was observed in the interquartile range/median values over time. CONCLUSION: TE interfaced with ultrasound in this hybrid machine presents no learning curve effect. After a short initial training session, a novice observer is able to perform high rates of reliable and very reliable TE measurements. KEY POINTS: • When performing liver stiffness measurements using a new hybrid machine composed of transient elastography interfaced with ultrasound, the rate of failures of measurements is very low, below 5%. • After a short training session and using ultrasound planning, a novice operator, whatever its expertise in ultrasound imaging, is capable of performing high rates of reliable and very reliable measurements. • No learning curve is needed for performing reliable liver stiffness measurements using this new hybrid machine.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Hepatopatias/diagnóstico por imagem , Hepatopatias/patologia , Radiologistas/educação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Curva de Aprendizado , Fígado/diagnóstico por imagem , Fígado/patologia , Masculino , Pessoa de Meia-Idade , Imagem Multimodal/métodos , Estudos Prospectivos , Reprodutibilidade dos Testes , Ultrassonografia/métodos , Adulto Jovem
3.
Ultrasound Med Biol ; 48(11): 2258-2266, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36050230

RESUMO

This study was aimed at determining whether liver stiffness measurements by 2-D shear wave elastography using GE's (2D-SWE-GE) and Canon's (2D-SWE-Canon) newest apparatus and vibration-controlled transient elastography (VCTE) share the same distribution of values compared with Hologic Supersonic Imagine (2D-SWE-SSI). In participants with chronic liver disease recruited in two university centers from August 2020 to February 2021, liver stiffness was measured the same day by the same operator with 2D-SWE-SSI plus one of the following devices: 2D-SWE-GE (n = 314), 2D-SWE-Canon (n = 311), and VCTE-M probe (n = 812). VCTE-M and 2D-SWE-SSI values shared the highest correlation and concordance coefficients (0.933 and 0.920, respectively) and a coefficient of variation below 20%, whatever the range of values. 2D-SWE-GE had the lowest variations, with 2D-SWE-SSI values below 13 kPa. However, both 2D-SWE-GE and 2D-SWE-Canon exhibited a frank underestimation of the high percentiles' 2D-SWE-SSI values with coefficients of variation of -21.7% and -25.8% from 13- to 17-kPa values, and -44.3% and -32.4% from 17-kPa values, respectively. In conclusion, knowledge of the vendor-specific distribution of values is mandatory for interpreting results obtained with different machines. If all four techniques behave closely in low values allowing excluding advanced chronic liver diseases in larger populations, discrepancies are observed in high percentile values.


Assuntos
Técnicas de Imagem por Elasticidade , Hepatopatias , Técnicas de Imagem por Elasticidade/métodos , Humanos , Fígado/diagnóstico por imagem , Cirrose Hepática/diagnóstico por imagem , Hepatopatias/diagnóstico por imagem , Reprodutibilidade dos Testes , Vibração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA