Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 69
Filtrar
1.
J Am Chem Soc ; 146(44): 30068-30077, 2024 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-39467819

RESUMO

The concept of programmable cascade reactions in charged microdroplets is introduced using carbon-carbon (C-C) bond formation via uncatalyzed Michael addition in a three-tier study culminating in programmable Hantzsch multicomponent, multistep reactions. In situ generated reactive oxygen species (ROS) from nonthermal plasma discharge are fused with charged water microdroplets (devoid of ROS) in real time for accelerated chemical reactions. This plasma-microdroplet fusion platform utilizing a coaxial spray configuration enabled product selection while avoiding unwanted side reactions. Hydrogen abstraction via ROS facilitated the formation of enolate anions without strong base use. Reaction enhancement factors >103 were calculated for plasma-microdroplet fusion versus microdroplet-only reactions. The platform programmability was showcased through (i) uncatalyzed 1,4-Michael addition of α,ß-unsaturated carbonyls, (ii) novel C-C bond formation via the use of pro-electrophilic amine and alcohol substrates─activated through collisions in the microdroplet environment to serve as Michael acceptors, and (iii) selective Hantzsch cascade reaction with cross-coupling products, avoiding side reactions including N-alkylation and self-coupling product formation. Milligram quantity product collection is achieved, showcasing plasma-microdroplet fusion as an effective tool for preparative-scale synthesis. Thus, the controlled generation of ROS via plasma discharge during charged water microdroplet evolution establishes a green synthetic method for uncatalyzed C-C bond formation.

2.
Malar J ; 23(1): 265, 2024 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-39215297

RESUMO

BACKGROUND: Accurate diagnosis and timely treatment are crucial in combating malaria. METHODS: A total of 449 samples were screened for Plasmodium falciparum infection by expert microscopy, qPCR, and three RDTs, namely Rapigen Biocredit Malaria Ag Pf (detecting HRP2 and pLDH on separate bands), Abbott NxTek Eliminate Malaria Ag Pf (detecting HRP2), and SD Bioline Malaria Ag Pf (detecting HRP2). hrp2/3 deletion typing was done by digital PCR. RESULTS: 45.7% (205/449) individuals tested positive by qPCR for P. falciparum with a mean parasite density of 12.5 parasites/µL. Using qPCR as reference, the sensitivity of microscopy was 28.3% (58/205), the Biocredit RDT was 52.2% (107/205), the NxTek RDT was 49.3% (101/205), and the Bioline RDT was 39.5% (81/205). When only samples with densities > 20 parasites/µL were included (n = 89), sensitivity of 62.9% (56/89) by microscopy, 88.8% (79/89) by Biocredit, 88.8% (79/89) by NxTek, and 78.7% (70/89) by Bioline were obtained. All three RDTs demonstrated specificities > 95%. The limits of detection (95% probability that a sample tested positive) was 4393 parasites/µL (microscopy), 56 parasites/µL (Biocredit, considering either HRP2 or pLDH), 84 parasites/µL (NxTek), and 331 parasites/µL (Bioline). None of the three qPCR-confirmed P. falciparum positive samples, identified solely through the pLDH target, or eight samples negative for all RDTs but qPCR-positive at densities > 20 parasites/µL carried hrp2/3 deletions. CONCLUSION: The Biocredit and NxTek RDTs demonstrated comparable diagnostic efficacies. All three RDTs performed better than microscopy.


Assuntos
Testes Diagnósticos de Rotina , Malária Falciparum , Plasmodium falciparum , Sensibilidade e Especificidade , Malária Falciparum/diagnóstico , Malária Falciparum/parasitologia , Humanos , Plasmodium falciparum/isolamento & purificação , Plasmodium falciparum/genética , Gana , Testes Diagnósticos de Rotina/métodos , Pré-Escolar , Adolescente , Adulto , Criança , Adulto Jovem , Feminino , Pessoa de Meia-Idade , Masculino , Microscopia/métodos , Lactente , Reação em Cadeia da Polimerase em Tempo Real/métodos , Idoso , Idoso de 80 Anos ou mais , Testes de Diagnóstico Rápido
3.
Analyst ; 149(22): 5504-5517, 2024 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-39420774

RESUMO

Oligosaccharides demonstrate many bioactivities with applications in the pharmaceutical, cosmetic, and food industries. They also serve as biomarkers for various diseases including cancer and glycogen storage disorders. These make the structural characterization of oligosaccharides very important. Unfortunately, the structural diversity found in saccharides make their characterization challenging, necessitating the development of sophisticated instrumentation to enable isomer differentiation. Herein, we report the ability of halide (Cl- and Br-) adducts to enable direct differentiation of oligosaccharide isomers using conventional collision-induced dissociation (CID) tandem MS (MS/MS). The halide adducts were generated by direct infusion nano-electrospray ionization (nESI). For the first time, this traditional nESI CID MS/MS platform was used to differentiate stereoisomers of trisaccharides (cellotriose ß(1 → 4) and maltotriose α(1 → 4), tetrasaccharides (cellotetraose and maltotetraose), and pentasaccharides (cellopentaose and maltopentaose)). In addition, the MS/MS of halide adducts enabled the differentiation of positional, structural, and linkage isomers from a total of 14 oligosaccharides. The isomer differentiation was realized by the generation of distinct diagnostic fragment ions in CID. We also performed principal component analysis using the entire range of MS/MS fragment ion profiles and found that negative-ion mode halide adduction provided more effective isomer differentiation compared with positive-ion mode sodium adduction. Finally, we demonstrated complex mixture analysis by spiking all 14 oligosaccharides into raw urine, of which we successfully distinguished species based on molecular weight (first dimension) and CID MS/MS fragmentation patterns as the second dimension separation. This work effectively showcases the potential to use direct infusion nESI-MS/MS to characterize synthetic oligosaccharide isomers in unpurified reaction mixture as well as from biofluids for diagnostic purposes.


Assuntos
Oligossacarídeos , Espectrometria de Massas por Ionização por Electrospray , Espectrometria de Massas em Tandem , Oligossacarídeos/química , Espectrometria de Massas em Tandem/métodos , Espectrometria de Massas por Ionização por Electrospray/métodos , Isomerismo , Humanos , Análise de Componente Principal
4.
Anal Chem ; 95(2): 1085-1094, 2023 01 17.
Artigo em Inglês | MEDLINE | ID: mdl-36534015

RESUMO

Recent advancements in mass spectrometry (MS) now enable all levels of protein structures to be characterized, including primary protein sequence, post-translational modifications, and three-dimensional protein conformations. However, protein conformational studies by MS require the use of many separate techniques that are performed independently of each other. Herein, we described a contained-electrospray (ES) experiment that has potential to integrate peptide/protein cross-linking with the general MS workflow. In our experiment, cross-linking of protein/peptide occurs simultaneously with ionization after analytes, and cross-linkers are sprayed from two separate ES emitters. The online cross-linking process occurring in the charged microdroplet environment was optimized using trilysine peptide and bis(sulfosuccinimidyl)suberate cross-linker. We detected the electrostatic complex between analyte and cross-linker, the mono-linked intermediate, and the fully cross-linked product, allowing us to correctly predict the sequence of reaction events in the cross-linking process. Importantly, we observed that the terminal fully cross-linked product is composed of two distinct conformations. In one form, the product involved cross-linking between two ε-NH2 amines in lysine residues, while the other conformer was formed by a reaction between one ε-NH2 amine and the N-terminus. The experimental conditions for selecting one cross-linked species over others during the online ES ionization-MS analysis have been detailed. Appropriate parameters enabled the reaction between α-lactalbumin proteins and cross-linkers using a non-denaturing spray condition. These results establish a framework for a future development in high-throughput structural MS method, where all levels of protein information can be gathered in a single experiment.


Assuntos
Proteínas , Espectrometria de Massas por Ionização por Electrospray , Espectrometria de Massas por Ionização por Electrospray/métodos , Proteínas/química , Peptídeos/química , Sequência de Aminoácidos , Conformação Proteica , Reagentes de Ligações Cruzadas/química
5.
Anal Chem ; 95(18): 7093-7099, 2023 05 09.
Artigo em Inglês | MEDLINE | ID: mdl-37102794

RESUMO

A high-throughput droplet imbibition mass spectrometry (MS) experiment is reported for the first time that allows direct analysis of ultra-small volumes of complex mixtures. In this experiment, an array of optimized tips of glass capillaries containing the analyte solution is sampled by rapidly moving charged microdroplets, which picks up (i.e., imbibes) the analyte and transfers it to a proximal mass spectrometer. The advantages associated with this droplet imbibition experiment include (1) ultra-small sample consumption (1.3 nL/min), which reduces the matrix effect in complex mixture analysis, and (2) high surface activity, which eliminates ion suppression effects caused by competition for the space charge on the droplet surface. Collectively, the enhanced surface effect and small flow rates dramatically increase the sensitivity of the droplet imbibition MS approach. This was experimentally shown by constructing calibration curves for cocaine analysis in human raw urine and whole blood, achieving 2 and 7 pg/mL limits of detection, respectively. The high-throughput feature was demonstrated by analyzing five structurally different compounds in 20 s intervals. With the measured flow rate of 1.3 nL/min on a 5 µm glass tip size, the results described in the current study showcase droplet imbibition MS to be a powerful and high-throughput alternative for conventional nano-electrospray ionization (flow rate <100 nL/min), which is the most efficient method for transferring small sample volumes to mass spectrometers.


Assuntos
Análise Química do Sangue , Espectrometria de Massas por Ionização por Electrospray , Urinálise , Humanos , Espectrometria de Massas por Ionização por Electrospray/métodos
6.
Anal Chem ; 95(13): 5635-5642, 2023 04 04.
Artigo em Inglês | MEDLINE | ID: mdl-36947664

RESUMO

Rare sugars have gained popularity in recent years due to their use in antiaging treatments, their ability to sweeten with few calories, and their ability to heal infections. Rare sugars are found in small quantities in nature, and they exist typically as isomeric forms of traditional sugars, rendering some challenges in their isolation, synthesis, and characterization. In this work, we present the first direct mass spectrometric approach for differentiating structural isomers of sucrose that differ only by their glycosidic linkages. The method employed a noncontact nanoelectrospray (nESI) platform capable of analyzing minuscule volumes (5 µL) of saccharides via the formation of halide adducts ([M+X]-; X = Cl and Br). Tandem mass spectrometry analysis of the five structural isomers of sucrose afforded diagnostic fragment ions that can be used to distinguish each isomer. Detailed mechanisms showcasing the distinct fragmentation pattern for each isomer are discussed. The method was applied to characterize and confirm the presence of all five selected rare sugars in raw honey complex samples. Aside from the five natural α isomers of sucrose, the method was also suitable for differentiating some ß isomers of the same glycosidic linkages, provided the monomeric sugar units are different. The halide adduct formation via the noncontact nESI source was also proven to be effective for oligosaccharides such as raffinose, ß-cyclodextrin, and maltoheptaose. The results from this study encourage the future development of methods that function with simple operation to enable straightforward characterization of small quantities of rare sugars.


Assuntos
Espectrometria de Massas por Ionização por Electrospray , Açúcares , Espectrometria de Massas por Ionização por Electrospray/métodos , Carboidratos , Espectrometria de Massas em Tandem/métodos , Glicosídeos , Sacarose , Isomerismo
7.
Mass Spectrom Rev ; : e21826, 2022 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-36524560

RESUMO

Chemical analysis by analytical instrumentation has played a major role in disease diagnosis, which is a necessary step for disease treatment. While the treatment process often targets specific organs or compounds, the diagnostic step can occur through various means, including physical or chemical examination. Chemically, the genome may be evaluated to give information about potential genetic outcomes, the transcriptome to provide information about expression actively occurring, the proteome to offer insight on functions causing metabolite expression, or the metabolome to provide a picture of both past and ongoing physiological function in the body. Mass spectrometry (MS) has been elevated among other analytical instrumentation because it can be used to evaluate all four biological machineries of the body. In addition, MS provides enhanced sensitivity, selectivity, versatility, and speed for rapid turnaround time, qualities that are important for instance in clinical procedures involving the diagnosis of a pediatric patient in intensive care or a cancer patient undergoing surgery. In this review, we provide a summary of the use of MS to evaluate biomarkers for newborn screening and cancer diagnosis. As many reviews have recently appeared focusing on MS methods and instrumentation for metabolite analysis, we sought to describe the biological basis for many metabolomic and additional omics biomarkers used in newborn screening and how tandem MS methods have recently been applied, in comparison to traditional methods. Similar comparison is done for cancer screening, with emphasis on emerging MS approaches that allow biological fluids, tissues, and breath to be analyzed for the presence of diagnostic metabolites yielding insight for treatment options based on the understanding of prior and current physiological functions of the body.

8.
Analyst ; 148(20): 5270-5278, 2023 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-37740330

RESUMO

Saccharides are increasingly used as biomarkers and for therapeutic purposes. Their characterization is challenging due to their low ionization efficiencies and inherent structural heterogeneity. Here, we illustrate how the coupling of online droplet-based reaction, in a form of contained electrospray (ES) ion source, with liquid chromatography (LC) tandem mass spectrometry (MS/MS) allows the comprehensive characterization of sucrose isomers. We used the reaction between phenylboronic acid and cis-diols for on-the-fly derivatization of saccharides eluting from the LC column followed by in situ MS/MS analysis, which afforded diagnostic fragment ions that enabled differentiation of species indistinguishable by chromatography or mass spectrometry alone. For example, chromatograms differing only by 2% in retention times were flagged to be different based on incompatible MS/MS fragmentation patterns. This orthogonal LC-contained-ES-MS/MS method was applied to confirm the presence of turanose, palatinose, maltulose, and maltose, which are structural isomers of sucrose, in three different honey samples. The reported workflow does not require modification to existing mass spectrometers, and the contained-ES platform itself acts both as the ion source and the reactor, all promising widespread application.


Assuntos
Sacarose , Espectrometria de Massas em Tandem , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida , Espectrometria de Massas por Ionização por Electrospray/métodos
9.
Angew Chem Int Ed Engl ; 62(51): e202311100, 2023 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-37770409

RESUMO

The fusion of non-thermal plasma with charged microdroplets facilitates catalyst-free N-alkylation for a variety of primary amines, without halide salt biproduct generation. Significant reaction enhancement (up to >200×) is observed over microdroplet reactions generated from electrospray. This enhancement for the plasma-microdroplet system is attributed to the combined effects of energetic collisions and the presence of reactive oxygen species (ROS). The ROS (e.g., O2 ⋅- ) act as a proton sink to increase abundance of free neutral amines in the charged microdroplet environment. The effect of ROS on N-alkylation is confirmed through three unique experiments: (i) utilization of radical scavenging reagent, (ii) characterization of internal energy distribution, and (iii) controls performed without plasma, which lacked reaction acceleration. Establishing plasma discharge in the wake of charged microdroplets as a green synthetic methodology overcomes two major challenges within conventional gas-phase plasma chemistry, including the lack of selectivity and product scale-up. Both limitations are overcome here, where dual tunability is achieved by controlling reagent concentration and residence time in the microdroplet environment, affording single or double N-alkylated products. Products are readily collected yielding milligram quantities in eight hours. These results showcase a novel synthetic strategy that represents a straightforward and sustainable C-N bond-forming process.

10.
Anal Chem ; 94(40): 14071-14078, 2022 10 11.
Artigo em Inglês | MEDLINE | ID: mdl-36179275

RESUMO

The ability to identify abnormalities in the body's saccharide profile is a promising means for early disease detection but requires analytical tools capable of detecting saccharides at low concentrations and/or for volume-limited samples. The preferred analysis approach for these compounds, liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS), often lacks sensitivity due to poor ionization efficiency. In this work, we employ a modified electrospray interface-termed contained-electrospray (contained-ESI) to couple accelerated droplet chemistry to conventional LC-MS for the online and automated separation, derivatization, and detection of saccharides. The chromatographic component enables complex sample and mixtures analysis with low sample volume requirements, while the enhanced reaction kinetics afforded by electrosprayed microdroplets facilitates rapid, on-the-fly derivatization to boost sensitivity. Derivatization occurs during ion formation as analytes elute from the column, eliminating the need for superfluous post-column derivatization hardware or complicated benchtop protocols. A grounded coupler was incorporated to shield the LC from the high-voltage ion source, and method conditions were optimized to accommodate the low flow rates preferred for microdroplet reactions. The new LC-contained-ESI-MS/MS platform was demonstrated for the analysis of several mono-, di-, and oligosaccharides using in-source droplet-based phenylboronic acid derivatization. Femtomole limits of detection were achieved for a 1 µL injection, representing sensitivity enhancement of 1-2 orders of magnitude over conventional LC-ESI-MS/MS without derivatization. In addition, isobaric saccharides that are difficult to differentiate by MS alone were easily distinguished. Method precision, accuracy, and linearity were established, and the ability to detect oligosaccharides at trace levels in human urine and plasma was demonstrated.


Assuntos
Espectrometria de Massas por Ionização por Electrospray , Espectrometria de Massas em Tandem , Ácidos Borônicos , Cromatografia Líquida/métodos , Humanos , Oligossacarídeos , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas em Tandem/métodos
11.
Anal Chem ; 94(12): 5132-5139, 2022 03 29.
Artigo em Inglês | MEDLINE | ID: mdl-35293204

RESUMO

Microfluidic paper-based analytical devices (µPADs) are emerging as a prominent platform for disease detection, specifically in developing countries. This paper device offer simplicity and affordability not typically seen in centralized laboratory settings. However, detection limits in µPADs are inadequate and often require test results to be read within a specific time interval to ensure accuracy. To overcome these challenges, we are developing an on-chip mass spectrometry (MS) detection strategy for immunoassays performed on paper substrates. Herein, we present our initial results from a proof-of-concept study toward the development of µPADs capable of storing immunoassay reagents within the confinements of the 3D device, automatic splitting of biofluid into four individual test zones, immuno-capture of the disease biomarker, and on-chip MS detection of the captured species. The reported study encourages the development of point-of-care and direct-to-customer testing using disposable µPADs to collect samples, followed by sensitive analysis using portable MSs. We demonstrate this capability using malaria Plasmodium falciparum histidine-rich protein 2 (PfHRP2) antigen detection.


Assuntos
Malária , Técnicas Analíticas Microfluídicas , Humanos , Imunoensaio/métodos , Malária/diagnóstico , Espectrometria de Massas , Microfluídica , Papel
12.
Anal Chem ; 94(27): 9618-9626, 2022 07 12.
Artigo em Inglês | MEDLINE | ID: mdl-35759462

RESUMO

Three-dimensional (3D) dried blood spheroids formed on hydrophobic paper are a new microsampling platform that can stabilize labile molecules in whole blood stored in ambient air at room temperature. In this study, we define the ideal conditions for preparing the dried blood spheroids. The physical morphology of 3D dried blood spheroids is found to be largely impacted by the unregulated relative humidity of the surrounding environment. A solution of KOH placed in an enclosed chamber offers a facile way to control humidity. We also report a general polymer coating strategy that serves to stabilize dried biofluids when prepared under ordinary ambient conditions without regulation of humidity. Dried blood spheroids coated in xanthan gum polymer exhibited enhanced chemical and physical stability. The same xanthan gum polymer provided chemical stability for 2D dried blood spots when compared with the conventional noncoated samples. We have expanded the application of xanthan gum to less viscous biofluids such as urine to induce an artificial protective barrier that also provides enhanced stability for labile performance-enhancing drugs stored at room temperature. The impact of polymer coating on direct biofluid analysis via paper spray mass spectrometry was determined by comparing the relative ionization efficiency, percent difference of ionization efficiency, and matrix effects of performance-enhancing drugs that were spiked in undiluted raw urine. Acceptable analytical performance was recorded for all three criteria, including high ionization efficiencies that ranged from 77 to 93% in the presence of the xanthan gum polymer.


Assuntos
Líquidos Corporais , Substâncias para Melhoria do Desempenho , Teste em Amostras de Sangue Seco/métodos , Interações Hidrofóbicas e Hidrofílicas , Espectrometria de Massas/métodos , Polímeros
13.
Anal Chem ; 94(10): 4417-4425, 2022 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-35226803

RESUMO

Dry-state microsampling techniques are convenient and advantageous for sample collection in resource-limited settings, including healthcare systems designed for the underserved population. In this work, a microsampling platform based on an embossed hydrophobic paper substrate is introduced together with three-dimensional (3D) printed cartridges that offer opportunities for rapid (<30 min) drying of the collected samples while also preserving sample integrity when the embossed paper chip is shipped at room temperature. More importantly, a new pinhole paper spray ionization method was developed that facilitates direct mass spectrometry (MS) analysis of the dried blood samples without prior sample preparation. We compared the direct pinhole paper spray MS method with a liquid chromatographic (LC) MS approach that relied upon electrospray ionization (ESI) after analytes present in the blood sample were extracted through liquid-liquid extraction. Limits of detection as low as 0.12 and 0.49 ng/mL were calculated for cocaine and its metabolite benzoylecgonine, respectively, when using the direct pinhole paper spray MS method. Analytical merits such as precision and accuracy, recovery, carryover effects, and analyte stability were all quantified for this new paper spray method and compared to the traditional LC-ESI-MS. Although LC-ESI-MS was observed to be 10× more sensitive, the linear dynamic range for both methods was determined to be the same, in the range of 1-500 ng/mL for both cocaine and benzoylecgonine analytes. When fully developed, the current microsampling strategy could offer an easy-to-use kit that can enable a more effective MS analysis of 20 µL dried blood samples delivered by mail. Both sensitivity (10×) and sample stability are found to be more superior for blood prepared in the embossed hydrophobic paper compared to samples prepared in the planar hydrophilic paper.


Assuntos
Cocaína , Cromatografia Líquida , Limite de Detecção , Espectrometria de Massas/métodos , Reprodutibilidade dos Testes , Espectrometria de Massas por Ionização por Electrospray , Temperatura
14.
Anal Chem ; 94(5): 2358-2365, 2022 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-35072466

RESUMO

Cellulose thread substrates offer a platform for microsampling and reactive ionization of free fatty acid (FFA) isomers for direct differentiation by mass spectrometry. Ambient corona discharge forms when direct current high voltage is applied to the tiny subfibers on the thread substrate in the presence of a polar spray solvent (MeOH/H2O, 2:1, v/v), facilitating chemical reactions across a C═C bond of unsaturated fatty acids. The process was applied for diagnosis of obesity, which we observed to show better discriminatory power when compared to determinations based on body mass index. Overall, the integrated reactive thread-based platform is capable of (i) microsampling and dry-state, room-temperature storage (>30 days) of the biofluids, (ii) in-capillary liquid/liquid extraction, and (iii) in situ epoxidation reactions to locate the C═C bond position in unsaturated fatty acids via reactions with reactive oxygen species present in ambient corona discharge. The study showcased the ability to correctly characterize FFAs, including degree of unsaturation, and the determination of their relative concentrations in clinical biofluid samples.


Assuntos
Ácidos Graxos não Esterificados , Ácidos Graxos Insaturados , Ácidos Graxos Insaturados/química , Humanos , Isomerismo , Espectrometria de Massas/métodos , Obesidade/diagnóstico
15.
Anal Chem ; 94(41): 14377-14384, 2022 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-36195476

RESUMO

In this work, we have developed a paper-based microfluidic device capable of remote biofluid collection followed by an analysis of the dried clinical samples using a miniature mass spectrometer. We have evaluated a portable mass spectrometer as a possible surveillance platform by analyzing the clinical malaria samples (whole blood) collected from Ghana. We synthesized pH-sensitive ionic probes and coupled them with monoclonal antibodies specific to the Plasmodium falciparum histidine-rich protein 2 (PfHRP2) malaria antigen. We then used the antibody-ionic probe conjugates in a paper-based immunoassay to capture PfHRP2 antigen from untreated whole blood. After the immunoassay, the bound ionic probes were cleaved, and the released mass tags were analyzed through an on-chip paper spray mass spectrometry strategy. During process optimization, we determined the detection limit for PfHRP2 in untreated human serum to be 0.216 nmol/L when using the miniature mass spectrometer. This sensitivity is comparable to the World Health Organization's suggested threshold of 0.227 nmol/L for PfHRP2, proving that our method will be applicable to diagnose symptomatic malaria infection (≥200 parasites per µL blood). The paper device can be stored at room temperature for at least 25 days without affecting the clinical outcome, with each stored paper chip offering good repeatability and reproducibility (RSD = 4-12%). The stability and sensitivity of the developed paper-based immunoassay platform will allow miniature mass spectrometers to be used for point-of-care malaria detection as well as in large-scale surveillance screening to aid eradication programs.


Assuntos
Malária Falciparum , Malária , Anticorpos Monoclonais , Antígenos de Protozoários , Histidina , Humanos , Imunoensaio/métodos , Malária/diagnóstico , Malária Falciparum/diagnóstico , Malária Falciparum/parasitologia , Espectrometria de Massas , Plasmodium falciparum/química , Proteínas de Protozoários , Reprodutibilidade dos Testes
16.
Anal Chem ; 94(43): 15093-15099, 2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-36251285

RESUMO

The Claisen rearrangement of aromatic allyl phenyl ether to 2-allyl phenol is known to be induced by heat, acid, and air-water interfacial (on-water) effects. In this work, we show that the combination of acid and interfacial effects in an "on-droplet" experiment accelerates this reaction even further (by a factor >10×). The reaction acceleration was achieved through a droplet imbibition mass spectrometry (MS) experiment that allows reactants to be deposited on rapidly moving (100 m/s), charged microdroplets while avoiding turbulent mixing. In this case, reactants are concentrated mainly at the surface of the short-lived microdroplets (microseconds), enabling enhanced interfacial effects. By doping n-butylamine in the spray solvent and subsequently exposing the resultant electrosprayed microdroplets to formic acid vapor, the ketone intermediate, 6-allylcyclohexa-2,4-dien-1-one, involved in this Claisen rearrangement was captured and characterized by tandem MS, successfully differentiating it from the corresponding isobaric reactant (allyl phenyl ether) and product (2-allyl phenol). Similar results showing rate acceleration and subsequent capture of the ketone intermediate via an instantaneous reaction with n-butylamine were demonstrated for p-methyl and p-nitro substituted allyl phenyl ether. Density functional theory calculations confirmed that the on-droplet reaction condition, with a high abundance of proton sources, is different from the neutral rearrangement. With a calculated free energy of activation of 5.2 kcal mol-1 for the protonated reactant, the on-droplet experimental condition provides a unique mechanism for catalyzing the Claisen rearrangement on the microsecond lifetime of the droplets. This experiment marks the first direct capture and detection of a short-lived ketone intermediate in the Claisen rearrangement, a task that is challenged by a thermodynamically favorable tautomerization step to give a more stabilized product (by 20 kcal/mol).


Assuntos
Éteres Fenílicos , Água , Solventes/química , Água/química , Cetonas
17.
Anal Chem ; 93(50): 16779-16786, 2021 12 21.
Artigo em Inglês | MEDLINE | ID: mdl-34874718

RESUMO

Online, droplet-based in-source chemical derivatization is accomplished using a coaxial-flow contained-electrospray ionization (contained-ESI) source to enhance sensitivity for the mass spectrometric analysis of saccharides. Derivatization is completed in microseconds by exploiting the reaction rate acceleration afforded by electrospray microdroplets. Significant improvements in method sensitivity are realized with minimal sample preparation and few resources when compared to traditional benchtop derivatizations. For this work, the formation of easily ionizable phenylboronate ester derivatives of several mono-, di-, and oligosaccharides is achieved. Various reaction parameters including concentration and pH were evaluated, and a Design of Experiments approach was used to optimize ion source parameters. Signal enhancements of greater than two orders of magnitude were observed for many mono- and disaccharides using in-source phenylboronic acid derivatization, resulting in parts-per-trillion (picomolar) limits of detection. In addition, amino sugars such as glucosamine, which do not ionize in negative mode, were detected at low parts-per-billion concentrations, and isobaric sugars such as lactose and sucrose were easily distinguished. The new in-source derivatization approach can be employed to expand the utility of ESI-MS analysis for compounds that historically experience limited sensitivity and detectability, while avoiding resource-intensive, bulk-phase derivatization procedures.


Assuntos
Espectrometria de Massas por Ionização por Electrospray
18.
Anal Chem ; 93(38): 13001-13007, 2021 09 28.
Artigo em Inglês | MEDLINE | ID: mdl-34524788

RESUMO

Enzyme-catalyzed hydrolysis of lipids was monitored directly in immiscible microdroplet environments using contained-electrospray mass spectrometry. Aqueous solution of the lipase enzyme from Pseudomonas cepacia and the chloroform solution of the lipids were sprayed from separate capillaries, and the resultant droplets were merged within a reaction cavity that is included at the outlet of the contained-electrospray ionization source. By varying the length of the reaction cavity, the interaction time between the enzyme and its substrate was altered, enabling the quantification of reaction product as a function of time. Consequently, enhancement factors were estimated by comparing rate constants derived from the droplet experiment to rate constants calculated from solution-phase conditions. These experiments showed enhancement factors greater than 100 in favor of the droplet experiment. By using various lipid types, two possible mechanisms were identified to account for lipase reactivity in aerosols: in-droplet reactions for relatively highly soluble lipids and a droplet coalescence mechanism that allows interfacial reactions for the two immiscible systems.


Assuntos
Lipídeos , Espectrometria de Massas por Ionização por Electrospray , Catálise , Hidrólise , Lipase
19.
Anal Chem ; 93(40): 13632-13640, 2021 10 12.
Artigo em Inglês | MEDLINE | ID: mdl-34590821

RESUMO

This study aims to introduce the concept of utilizing a solid-phase extraction (SPE) cartridge for remote biofluid collection, followed by direct sample analysis at a later time. For this, a dried matrix spot was prepared in a syringe, in the form of SPE cartridge for the first time to enable small biofluid collection (microsampling), storage, shipment, and online electrospray ionization (ESI) mass spectrometry (MS) analysis of the stored dried samples. The SPE sorbents were packed into an ESI syringe and the resultant cartridge was used for sampling small volumes (<20 µL) of different complex biological fluids including blood, plasma, serum, and urine. The collected sample was stored in the dry state within the confinement of the SPE sorbent at room temperature, and analyte stability (e.g., diazepam) was maintained for more than a year. Direct coupling of the SPE cartridge to MS provides excellent accuracy, precision, and sensitivity for analyzing illicit drugs present in the biofluid. The corresponding mechanism of wrong-way positive ion generation from highly basic elution solvents was explored. Without chromatography, our direct SPE-ESI-MS analysis technique afforded detection limits as low as 26 and 140 pg/mL for raw urine and untreated plasma, respectively. These promising results proved that the new syringe-based SPE cartridge can serve as a good alternative to conventional microsampling techniques in terms of analyte stability, ease of operation and versatility, and analytical sensitivity and speed.


Assuntos
Extração em Fase Sólida , Espectrometria de Massas por Ionização por Electrospray , Diazepam
20.
Anal Chem ; 93(4): 2440-2448, 2021 02 02.
Artigo em Inglês | MEDLINE | ID: mdl-33395521

RESUMO

Ionic wind comprising of the drag of bulk air in the presence of electrical discharge enabled N-alkylation reactions under ambient conditions. By introducing reactant vapor as part of the discharge gas during the stages of electron acceleration, both neutral and charged species of the selected organic reactant gain energy through ion-neutral collisions, which is identified to facilitate chemical reactions. By performing this experiment in front of a mass spectrometer, chemical reactions occurring in the ionic wind were examined in real time. Reaction energetics were characterized via the use of benzylamine, which freely dissociates at a critical energy of 3.6 eV to give the resonance-stabilized benzyl cation as reaction intermediate. Benzylamine and many other primary amines were observed to undergo N-alkylation reactions by engaging in self-cross-coupling ion-molecule reactions. Because of the high energies of species involved and the fact that the ionic wind is generated at atmospheric pressure, it was straightforward to collect the ensuing reaction products without the use of complicated instrumentation. Water served as an effective collecting solvent allowing >0.1 mg of intact N-alkylated products to be collected under ambient conditions using a single plasma emitter. A novel N-alkylation reaction pathway involving the synthesis of N-benzyl-1-(methyleneamino)-1-phenylmethanaime was discovered through this offline product collection experiment, providing new insight into benzylamine dissociation in the ionic wind.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA