Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Tipo de documento
Ano de publicação
Intervalo de ano de publicação
1.
J Vasc Surg ; 79(2): 198-206.e15, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37967588

RESUMO

OBJECTIVE: We assessed the suitability of two triple branch arch devices (aBranch) (Terumo aortic and Cook Medical) and a balloon-expandable covered stent (VBX, W. L. Gore & Associates, Johnson & Johnson) to incorporate the brachiocephalic trunk (BCT) in a cohort previously treated with hybrid thoracic endovascular repair (TEVAR). METHODS: This is a single-center, retrospective, all-comers, preclinical suitability study. We conducted an analysis of preoperative computed tomography scans in surgical patients between 1999 and 2022 in a single vascular surgery unit. The primary outcome was the aortic suitability of aBranch devices and VBX as mating stent for BCT in previous hybrid TEVAR. Hybrid repair of the aortic arch included TEVAR, fenestrated or branched TEVAR associated with any surgical debranching of the supra-aortic trunks and chimney TEVAR with proximal landing in zones 0 to 2. Secondary outcomes included (i) suitability assessment when excluding minor instruction for use (IFU) criteria, (ii) a comparison of suitable and nonsuitable patients, (iii) risk factors analysis for nonsuitability, and (iv) a description of the exclusion causes. RESULTS: During the study period, 120 patients were treated. Among elective patients (n = 73), the suitability of any aBranch was 82.2% (60/73) and VBX was suitable in 64.4% of BCTs (47/73). The aBranch suitable patients had a significantly longer sinotubular-BCT length (P = .017) and smaller distal ascending aorta (P = .043) as compared with nonsuitable ones. The suitability of Terumo Aortic and Cook Medical devices was 52.1% (38/73) and 46.6% (34/73), respectively. When minor IFU criteria were ignored, suitability increased to 82.2% (60/73) and 63.0% (46/73), respectively. Left common carotid artery diameter and sinotubular-BCT length were significant nonsuitability risk factors for Terumo Aortic aBranch in multivariable analysis. No associations were found for Cook Medical device. The outcomes were tested in the entire cohort demonstrating a global suitability of 82.9%, increasing to 86.3% when ignoring minor IFUs. VBX was anatomically suitable to use in BCT in 73.2% of patient BCTs. CONCLUSIONS: aBranch devices are anatomically suitable in a vast majority of patients (86%) undergoing hybrid TEVAR. The innominate artery seems eligible for incorporation with VBX in almost two-thirds of patients. This mating stent may help to overcome some minor IFU restrictions.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Prótese Vascular , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Correção Endovascular de Aneurisma , Implante de Prótese Vascular/efeitos adversos , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/etiologia , Estudos Retrospectivos , Procedimentos Endovasculares/efeitos adversos , Desenho de Prótese , Stents , Resultado do Tratamento
2.
J Endovasc Ther ; : 15266028241255541, 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38778640

RESUMO

PURPOSE: To evaluate the influence of endograft fixation type on the incidence, treatment, and outcomes of type III endoleaks (TIIIELs). MATERIALS AND METHODS: Abdominal aortic aneurysms (AAAs) treated with bifurcated endografts between 1994 and 2020 were prospectively collected and reviewed. The endograft included were classified as "Anatomical Fixation" (AF) (Powerlink [Endologix] and AFX [Endologix]) or "Proximal Fixation" (PF). The primary outcome was the incidence of TIIIEL over time, stratified by fixation type. Secondary outcomes included between-group comparisons of baseline characteristics, intraoperative details during TIIIEL correction, and survival analysis after TIIIEL diagnosis. RESULTS: A total of 2065 endovascular aneurysm repairs were performed: 872 (42.2%) with AF and 1193 (57.8%) with PF devices. The estimated incidence of TIIIEL at 1, 5, and 10 years was 0.4%, 4.2%, and 7.3%, and 0.5%, 3.2%, and 4.6% for AF and PF, respectively (p=0.157), and fixation type was not associated with TIIIEL development in the competing risk regression model (p=0.101). The cumulative overall survival rate in patients diagnosed with TIIIEL did not differ significantly between the groups (p=0.077). The rate of recurrent TIIIELs was significantly lower in the AF group (7.1% vs 22.7%; p=0.044); however, no significant difference was found in secondary reintervention between the two groups (11.9% vs 27.3%, p=0.074). Patients with angulated and calcified aortic neck (SHR 3.4, 95% CI 1.2-9.6, p=0.022) and larger aneurysms (SHR 1.2; 95% CI 1.1-1.3; p<0.001) had a higher risk of TIIIEL. Likewise, the use of three or more endograft components increased the risk of TIIIEL by 3.1 times (SHR 3.1; 95% CI 1.7-5.4; p<0.001). CONCLUSIONS: The occurrence of TIIIELs was not affected by the type of endograft fixation. For larger abdominal aortic aneurysms (AAAs) and aneurysms with angulated and calcified aortic necks, there is a higher likelihood of developing TIIIELs during follow-up, regardless of the endograft type used. CLINICAL IMPACT: The type of fixation does not influence the incidence of TIII ELs. EVAR in larger AAAs and aneurysms with angulated and calcified aortic necks have a higher risk of developing TIII EL. Moreover, the risk of TIII EL is considerably increased by the use of three or more modular components.

SELEÇÃO DE REFERÊNCIAS