Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 108
Filtrar
1.
Am J Physiol Heart Circ Physiol ; 326(4): H1037-H1044, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38391315

RESUMO

Recently, a novel method to estimate wedge pressure (Pw)-corrected minimal microvascular resistance (MR) was introduced. However, this method has not been validated since, and there are some theoretical concerns regarding the impact of different physiological conditions on the derivation of Pw measurements. This study sought to validate the recently introduced method to estimate Pw-corrected MR in a Doppler-derived study population and to evaluate the impact of different physiological conditions on the Pw measurements and the derivation of Pw-corrected MR. The method to derive "estimated" hyperemic microvascular resistance (HMR) without the need for Pw measurements was validated by estimating the coronary fractional flow reserve (FFRcor) from myocardial fractional flow reserve (FFRmyo) in a Doppler-derived study population (N = 53). From these patients, 24 had hyperemic Pw measurements available for the evaluation of hyperemic conditions on the derivation of Pw and its effect on the derivation of both "true" (with measured Pw) and "estimated" Pw-corrected HMR. Nonhyperemic Pw differed significantly from Pw measured in hyperemic conditions (26 ± 14 vs. 35 ± 14 mmHg, respectively, P < 0.005). Nevertheless, there was a strong linear relationship between FFRcor and FFRmyo in nonhyperemic conditions (R2 = 0.91, P < 0.005), as well as in hyperemic conditions (R2 = 0.87, P < 0.005). There was a strong linear relationship between "true" HMR and "estimated" HMR using either nonhyperemic (R2 = 0.86, P < 0.005) or hyperemic conditions (R2 = 0.85, P < 0.005) for correction. In contrast to a modest agreement between nonhyperemic Pw-corrected HMR and apparent HMR (R2 = 0.67, P < 0.005), hyperemic Pw-corrected HMR showed a strong agreement with apparent HMR (R2 = 0.88, P < 0.005). We validated the calculation method for Pw-corrected MR in a Doppler velocity-derived population. In addition, we found a significant impact of hyperemic conditions on the measurement of Pw and the derivation of Pw-corrected HMR.NEW & NOTEWORTHY The following are what is known: 1) wedge-pressure correction is often considered for the derivation of indices of minimal microvascular resistance, and 2) the Yong method for calculating wedge pressure-corrected index of microvascular resistance (IMR) without balloon inflation has never been validated in a Doppler-derived population and has not been tested under different physiological conditions. This study 1) adds validation for the Yong method for calculated wedge-pressure correction in a Doppler-derived study population and 2) shows significant influence of the physiological conditions on the derivation of coronary wedge pressure.


Assuntos
Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Hiperemia , Humanos , Vasos Coronários/diagnóstico por imagem , Coração , Velocidade do Fluxo Sanguíneo , Circulação Coronária/fisiologia , Angiografia Coronária
2.
Eur Heart J ; 44(30): 2862-2869, 2023 08 07.
Artigo em Inglês | MEDLINE | ID: mdl-37350567

RESUMO

AIMS: The microvascular resistance reserve (MRR) was introduced as a means to characterize the vasodilator reserve capacity of the coronary microcirculation while accounting for the influence of concomitant epicardial disease and the impact of administration of potent vasodilators on aortic pressure. This study aimed to evaluate the diagnostic and prognostic performance of MRR. METHODS AND RESULTS: A total of 1481 patients with stable symptoms and a clinical indication for coronary angiography were included from the global ILIAS Registry. MRR was derived as a function of the coronary flow reserve (CFR) divided by the fractional flow reserve (FFR) and corrected for driving pressure. The median MRR was 2.97 [Q1-Q3: 2.32-3.86] and the overall relationship between MRR and CFR was good [correlation coefficient (Rs) = 0.88, P < 0.005]. The difference between CFR and MRR increased with decreasing FFR [coefficient of determination (R2) = 0.34; Coef.-2.88, 95% confidence interval (CI): -3.05--2.73; P < 0.005]. MRR was independently associated with major adverse cardiac events (MACE) at 5-year follow-up [hazard ratio (HR) 0.78; 95% CI 0.63-0.95; P = 0.024] and with target vessel failure (TVF) at 5-year follow-up (HR 0.83; 95% CI 0.76-0.97; P = 0.047). The optimal cut-off value of MRR was 3.0. Based on this cut-off value, only abnormal MRR was significantly associated with MACE and TVF at 5-year follow-up in vessels with functionally significant epicardial disease (FFR <0.75). CONCLUSION: MRR seems a robust indicator of the microvascular vasodilator reserve capacity. Moreover, in line with its theoretical background, this study suggests a diagnostic advantage of MRR over other indices of vasodilatory capacity in patients with hemodynamically significant epicardial coronary artery disease.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Humanos , Prognóstico , Estenose Coronária/diagnóstico , Doença da Artéria Coronariana/diagnóstico , Angiografia Coronária , Vasodilatadores , Sistema de Registros , Vasos Coronários/diagnóstico por imagem , Valor Preditivo dos Testes , Microcirculação
3.
Am J Physiol Renal Physiol ; 325(3): F263-F270, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37382495

RESUMO

Renal sympathetic innervation is important in the control of renal and systemic hemodynamics and is a target for pharmacological and catheter-based therapies. The effect of a physiological sympathetic stimulus using static handgrip exercise on renal hemodynamics and intraglomerular pressure in humans is unknown. We recorded renal arterial pressure and flow velocity in patients with a clinical indication for coronary or peripheral angiography using a sensor-equipped guidewire during baseline, handgrip, rest, and hyperemia following intrarenal dopamine (30 µg/kg). Changes in perfusion pressure were expressed as the change in mean arterial pressure, and changes in flow were expressed as a percentage with respect to baseline. Intraglomerular pressure was estimated using a Windkessel model. A total of 18 patients (61% male and 39% female) with a median age of 57 yr (range: 27-85 yr) with successful measurements were included. During static handgrip, renal arterial pressure increased by 15.2 mmHg (range: 4.2-53.0 mmHg), whereas flow decreased by 11.2%, but with a large variation between individuals (range: -13.4 to 49.8). Intraglomerular pressure increased by 4.2 mmHg (range: -3.9 to 22.1 mmHg). Flow velocity under resting conditions remained stable, with a median of 100.6% (range: 82.3%-114.6%) compared with baseline. During hyperemia, maximal flow was 180% (range: 111%-281%), whereas intraglomerular pressure decreased by 9.6 mmHg (interquartile range: 4.8 to 13.9 mmHg). Changes in renal pressure and flow during handgrip exercise were significantly correlated (ρ = -0.68, P = 0.002). Measurement of renal arterial pressure and flow velocity during handgrip exercise allows the identification of patients with higher and lower sympathetic control of renal perfusion. This suggests that hemodynamic measurements may be useful to assess the response to therapeutic interventions aimed at altering renal sympathetic control.NEW & NOTEWORTHY Renal sympathetic innervation is important in the homeostasis of systemic and renal hemodynamics. We showed that renal arterial pressure significantly increased and that flow decreased during static handgrip exercise using direct renal arterial pressure and flow measurements in humans, but with a large difference between individuals. These findings may be useful for future studies aimed to assess the effect of interventions that influence renal sympathetic control.


Assuntos
Força da Mão , Hiperemia , Humanos , Masculino , Feminino , Força da Mão/fisiologia , Hemodinâmica/fisiologia , Rim , Pressão Arterial , Pressão Sanguínea/fisiologia , Sistema Nervoso Simpático
4.
Catheter Cardiovasc Interv ; 101(6): 1128-1133, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36994878

RESUMO

OBJECTIVES: The current study sought to determine whether low-dose dobutamine stress echocardiography (DSE) during transcatheter edge-to-edge mitral valve repair (TMVR) can predict residual mitral regurgitation (MR) at discharge. BACKGROUND: In most patients, TMVR can successfully reduce MR from severe to mild or moderate. However, general anesthesia during the intervention affects hemodynamics and MR assessment. At discharge transthoracic echocardiogram residual MR (>moderate) is present in 10%-30% of patients which is associated with worse clinical outcome. METHODS: In consecutive patients the severity of MR was determined at baseline, immediately after TMVR clip implantation and subsequently during low-dose DSE (both under general anesthesia) and at discharge. RESULTS: A total of 39 patients were included (mean age 76.1 ± 8.1 years, 39% male, 56% functional MR, 41% left ventricular ejection fraction < 45%). An increase of MR during DSE was seen in 11 patients, of whom 6 (55%) showed >moderate MR at discharge. None of the 28 patients without an increase of MR during DSE showed >moderate MR at discharge. The diagnostic performance of the test could be established at a sensitivity of 100% and a specificity of 85% in unselected patients. CONCLUSIONS: DSE during TMVR is a useful tool to predict residual MR at discharge. It could support procedural decision making, including implantation of additional clips and thus potentially improve clinical outcome.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Masculino , Idoso , Idoso de 80 Anos ou mais , Feminino , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Volume Sistólico , Ecocardiografia sob Estresse , Resultado do Tratamento , Função Ventricular Esquerda , Cateterismo Cardíaco/efeitos adversos
5.
Catheter Cardiovasc Interv ; 99(3): 844-852, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34766734

RESUMO

AIMS: We evaluated the occurrence and physiology of respiration-related beat-to-beat variations in resting Pd/Pa and FFR during intravenous adenosine administration, and its impact on clinical decision-making. METHODS AND RESULTS: Coronary pressure tracings in rest and at plateau hyperemia were analyzed in a total of 39 stenosis from 37 patients, and respiratory rate was calculated with ECG-derived respiration (EDR) in 26 stenoses from 26 patients. Beat-to-beat variations in FFR occurred in a cyclical fashion and were strongly correlated with respiratory rate (R2  = 0.757, p < 0.001). There was no correlation between respiratory rate and variations in resting Pd/Pa. When single-beat averages were used to calculate FFR, mean ΔFFR was 0.04 ± 0.02. With averaging of FFR over three or five cardiac cycles, mean ΔFFR decreased to 0.02 ± 0.02, and 0.01 ± 0.01, respectively. Using a FFR ≤ 0.80 threshold, stenosis classification changed in 20.5% (8/39), 12.8% (5/39) and 5.1% (2/39) for single-beat, three-beat and five-beat averaged FFR. The impact of respiration was more pronounced in patients with pulmonary disease (ΔFFR 0.05 ± 0.02 vs 0.03 ± 0.02, p = 0.021). CONCLUSION: Beat-to-beat variations in FFR during plateau hyperemia related to respiration are common, of clinically relevant magnitude, and frequently lead FFR to cross treatment thresholds. A five-beat averaged FFR, overcomes clinically relevant impact of FFR variation.


Assuntos
Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Hiperemia , Adenosina , Cateterismo Cardíaco/métodos , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/terapia , Vasos Coronários , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Humanos , Valor Preditivo dos Testes , Respiração , Índice de Gravidade de Doença , Resultado do Tratamento , Vasodilatadores
6.
Catheter Cardiovasc Interv ; 98(3): 503-510, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33029937

RESUMO

OBJECTIVES: This final report from the REMEDEE Registry assessed the long-term safety and efficacy of the dual-therapy COMBO stent in a large unselected patient population. BACKGROUND: The bio-engineered COMBO stent (OrbusNeich Medical BV, The Netherlands) is a dual-therapy pro-healing stent. Data of long-term safety and efficacy of the this stent is lacking. METHODS: The prospective, multicenter, investigator-initiated REMEDEE Registry evaluated clinical outcomes after COMBO stent implantation in daily clinical practice. One thousand patients were enrolled between June 2013 and March 2014. RESULTS: Five-year follow-up data were obtained in 97.2% of patients. At 5-years, target lesion failure (TLF) (composite of cardiac death, target-vessel myocardial infarction, or target lesion revascularization) was present in 145 patients (14.8%). Definite or probable stent thrombosis (ST) occurred in 0.9%, with no additional case beyond 3-years of follow-up. In males, 5-year TLF-rate was 15.6 versus 12.6% in females (p = .22). Patients without diabetes mellitus (DM) had TLF-rate of 11.4%, noninsulin-treated DM 22.7% (p = .001) and insulin-treated DM 41.2% (p < .001). Patients presenting with non-ST segment elevation acute coronary syndrome (NSTE-ACS) had higher incidence of TLF compared to non-ACS (20.4 vs. 13.3%; p = .008), while incidence with STE-ACS was comparable to non-ACS (10.7 vs. 13.3%; p = .43). CONCLUSION: Percutaneous coronary intervention with the dual-therapy COMBO stent in unselected patient population shows low rates of TLF and ST to 5 years. Remarkably, no case of ST was noted beyond 3 years.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Feminino , Humanos , Masculino , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros , Fatores de Risco , Stents , Fatores de Tempo , Resultado do Tratamento
7.
Catheter Cardiovasc Interv ; 97(5): 797-804, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-32198837

RESUMO

BACKGROUND: The COMBO drug eluting stent is a novel device with luminal endothelial progenitor cell capture technology for rapid homogeneous endothelialization. METHODS AND RESULTS: We examined for sex differences in 1-year outcomes after COMBO stenting from the COMBO collaboration, a pooled patient-level dataset from the MASCOT and REMEDEE multicenter registries. The primary endpoint was 1-year target lesion failure (TLF), composite of cardiac death, target vessel-myocardial infarction (TV-MI), or clinically driven target lesion revascularization (CD-TLR). Secondary outcomes included stent thrombosis (ST). Adjusted outcomes were assessed using Cox regression methods. The study included 861 (23.8%) women and 2,753 (76.2%) men. Women were older with higher prevalence of several comorbidities including diabetes mellitus. Risk of 1-year TLF was similar in both sexes (3.8% vs. 3.9%, HR 0.92, 95% CI 0.59-1.42, p = .70), without sex differences in the incidence of cardiac death (1.6% vs. 1.5%, p = .78), TV-MI (1.5% vs. 1.1%, p = .32), or CD-TLR (2.0% vs. 2.2%, p = .67). Definite or probable ST occurred in 0.4% women and 1.0% men (HR 0.26, 95% CI 0.06-1.11, p = .069). CONCLUSIONS: Despite greater clinical risks at baseline, women treated with COMBO stents had similarly low 1-year TLF and other ischemic outcomes compared to men.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Feminino , Humanos , Masculino , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Fatores de Risco , Caracteres Sexuais , Stents , Fatores de Tempo , Resultado do Tratamento
8.
Cardiovasc Drugs Ther ; 35(2): 309-320, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33515411

RESUMO

PURPOSE: The COMBO biodegradable polymer sirolimus-eluting stent includes endothelial progenitor cell capture (EPC) technology for rapid endothelialization, which may offer advantage in acute coronary syndromes (ACS). We sought to analyze the performance of the COMBO stent by ACS status and ACS subtype. METHODS: The COMBO collaboration (n = 3614) is a patient-level pooled dataset from the MASCOT and REMEDEE registries. We evaluated outcomes by ACS status, and ACS subtype in patients with ST segment elevation myocardial infarction (STEMI) or non-STEMI (NSTEMI) versus unstable angina (UA). The primary endpoint was 1-year target lesion failure (TLF), composite of cardiac death, target vessel myocardial infarction, or clinically driven target lesion revascularization. Secondary outcomes included stent thrombosis (ST). RESULTS: We compared 1965 (54%) ACS and 1649 (46.0%) non-ACS patients. ACS presentations included 40% (n = 789) STEMI, 31% (n = 600) NSTEMI, and 29% (n = 576) UA patients. Risk of 1-year TLF was greater in ACS patients (4.5% vs. 3.3%, HR 1.51 95% CI 1.01-2.25, p = 0.045) without significant differences in definite/probable ST (1.1% vs 0.5%, HR 2.40, 95% CI 0.91-6.31, p = 0.08). One-year TLF was similar in STEMI, NSTEMI, and UA (4.8% vs 4.8% vs. 3.7%, p = 0.60), but definite/probable ST was higher in STEMI patients (1.9% vs 0.5% vs 0.7%, p = 0.03). Adjusted outcomes were not different in MI versus UA patients. CONCLUSIONS: Despite the novel EPC capture technology, COMBO stent PCI was associated with somewhat greater risk of 1-year TLF in ACS than in non-ACS patients, without significant differences in stent thrombosis. No differences were observed in 1-year TLF among ACS subtypes.


Assuntos
Síndrome Coronariana Aguda/cirurgia , Stents Farmacológicos/estatística & dados numéricos , Células Progenitoras Endoteliais/metabolismo , Intervenção Coronária Percutânea/métodos , Síndrome Coronariana Aguda/classificação , Síndrome Coronariana Aguda/complicações , Síndrome Coronariana Aguda/mortalidade , Angina Instável/complicações , Trombose Coronária/epidemiologia , Stents Farmacológicos/efeitos adversos , Humanos , Infarto do Miocárdio/classificação , Infarto do Miocárdio/complicações , Desenho de Prótese , Fatores de Risco , Sirolimo/administração & dosagem , Fatores de Tempo
9.
Artigo em Inglês | MEDLINE | ID: mdl-32964556

RESUMO

BACKGROUND: Chronic kidney disease (CKD) patients undergoing percutaneous coronary intervention (PCI) experience greater ischemic events including clinically driven target lesion revascularization (CD-TLR). Whether the COMBO biodegradable-polymer sirolimus-eluting stent promotes better outcomes in these patients by virtue of endothelial progenitor cell capture technology is unknown. OBJECTIVE: We examined one-year outcomes by CKD status from the COMBO collaboration. METHODS: The COMBO collaboration was a patient-level pooled dataset from the REMEDEE and MASCOT registries (3,614 patients) of all-comers undergoing attempted COMBO stent PCI. The primary endpoint was one-year target lesion failure (TLF), composite of cardiac death, target-vessel myocardial infarction (TV-MI) or CD-TLR. Secondary endpoints included stent thrombosis (ST). RESULTS: The study included 6.4% (n = 231) CKD and 93.6% (n = 3,361) non-CKD patients. CKD patients were older and included more women with greater prevalence of several comorbidities but similar rate of acute coronary syndrome (50.6% vs. 54.5%, p = .26). CKD patients underwent radial PCI less often (56.1% vs. 70.3%, p < .001) and received clopidogrel (78.6% vs. 68.3%) more often (p = .004). One-year TLF occurred in 7.9% CKD vs. 3.7% non-CKD patients, p = .001. CKD patients also demonstrated greater incidence of cardiac death (6.2% vs. 1.2%, p < .0001), TV-MI (2.7% vs. 1.1%, p = .04) but similar CD-TLR (2.7% vs 2.2%, p = .61) and definite/probable ST (1.4% vs. 0.8%, p = .42), compared to non-CKD patients. CONCLUSIONS: CKD patients treated with COMBO stents had significantly greater incidence of one-year TLF compared to non-CKD patients driven by cardiac death and to a lesser extent TV-MI but not CD-TLR. They had similar rates of definite/probable ST.

10.
Catheter Cardiovasc Interv ; 95(1): 89-96, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-30968559

RESUMO

BACKGROUND: Patients with acute coronary syndrome (ACS) might represent a specific subgroup, in which bioresorbable scaffold implantation in percutaneous coronary intervention (PCI), might lead to better outcomes when compared to conventional treatment with metallic drug eluting stents. In this prespecified subgroup analysis of the Amsterdam Investigator-Initiated Absorb Strategy All-Comers (AIDA) trial, we evaluated the clinical outcomes of Absorb bioresorbable vascular scaffold (BVS) versus Xience everolimus eluting stent (EES) treated patients presenting either with or without ACS. METHODS AND RESULTS: We classified AIDA patients on the basis of clinical presentation of ACS or of no-ACS. The rate of the 2-year primary endpoint of target vessel failure (TVF) was similar after treatment with Absorb BVS or Xience EES in ACS patients (10.2% versus 9.0% respectively; P = 0.49) and in no-ACS patients (11.7% versus 10.7%, respectively; P = 0.67) Definite or probable device thrombosis occurred more frequently with Absorb BVS compared to Xience EES in ACS patients (4.3% versus 1.7%, respectively, P = 0.03) as well as in no-ACS patients (2.4% versus 0.2%, respectively; P = 0.002). There were no statistically significant interactions between clinical presentation and randomized device modality for TVF (P = 0.80) and for the endpoint of definite or probable device thrombosis (P = 0.17). CONCLUSION: In the AIDA trial, the 2-year outcomes of PCI with Absorb BVS versus Xience EES were consistent in ACS and no-ACS patients: similar rates for TVF and consistently higher rates of definite or probable stent thrombosis under Absorb BVS versus Xience EES. There were no statistically significant interactions between clinical presentation and randomized device modality.


Assuntos
Implantes Absorvíveis , Síndrome Coronariana Aguda/terapia , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Everolimo/administração & dosagem , Metais , Intervenção Coronária Percutânea/instrumentação , Síndrome Coronariana Aguda/diagnóstico por imagem , Idoso , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Trombose Coronária/etiologia , Everolimo/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Fatores de Risco , Método Simples-Cego , Fatores de Tempo , Resultado do Tratamento
11.
Catheter Cardiovasc Interv ; 94(3): 342-347, 2019 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-30565371

RESUMO

BACKGROUND: The bio-engineered COMBO stent (OrbusNeich Medical BV, The Netherlands) is a dual-therapy pro-healing stent. This novel technology may allow a shorter duration of dual antiplatelet therapy (DAPT) after stenting. We present the first 3 year clinical outcomes of patients treated with COMBO stent. METHODS AND RESULTS: The prospective, multicenter, investigator-initiated, all-comers REMEDEE Registry evaluates clinical outcomes after COMBO stent treatment. A 1,000 patients were enrolled between June 2013 and March 2014. Patients had a mean of 65 years ±11, 26% of the patients were females and 18% diabetics. More than 50% of patients presented with acute coronary syndrome, 60% of treated lesions were AHA/ACC lesion type B2 or C. Target lesion failure (TLF) at 3 year follow-up occurred in 10.7% of patients (N = 105). The separate components cardiac death, target vessel myocardial infarction and target lesion revascularization occurred in 4.1%, 2.0%, and 7.1%, respectively of patients. Definite stent thrombosis (ST) was observed in 0.7% of all patients. At 3-year follow-up there were only 73 patients taking DAPT. CONCLUSIONS: At 3-year follow-up, patients treated with COMBO stent in the present large prospective all-comers cohort, continue to show good clinical outcomes. Clinicaltrials.gov identifier: NCT01874002. CONDENSED ABSTRACT: The COMBO stent is a sirolimus-eluting stent with a luminal anti-CD34-antibody layer, that binds endothelial progenitor cells. These cells can differentiate to endothelial cells and stimulate early endothelialization of the stent. The REMEDEE Registry is the first large, multicenter, prospective, cohort study evaluating the clinical outcomes of 1,000 all-comers patients treated with COMBO stent. Target lesion failure at 3 year follow-up was 10.7% and the rate of definite ST was 0.7%.


Assuntos
Síndrome Coronariana Aguda/terapia , Doença da Artéria Coronariana/terapia , Intervenção Coronária Percutânea/instrumentação , Stents , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/mortalidade , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Trombose Coronária/etiologia , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Estudos Prospectivos , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
12.
Catheter Cardiovasc Interv ; 91(7): 1212-1218, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-28868810

RESUMO

OBJECTIVES: To assess the long-term safety and clinical efficacy of the Genous endothelial progenitor cell capturing stent (ECS) compared with the TAXUS Liberté paclitaxel-eluting stent (PES) in lesions with a high risk of restenosis. BACKGROUND: Instead of the use of cytotoxic or cytostatic drugs in drug-eluting stents, a "pro-healing" approach in ECS may overcome impeded healing response due to delayed functional endothelialization of the stent struts. METHODS: In the prospective, randomized TRIAS pilot study 193 patients with coronary artery lesions carrying a high risk of restenosis were included (ECS: n = 98, PES: n = 95). The primary focus of this analysis was target vessel failure (TVF) at 5 years. Dual antiplatelet therapy was prescribed for ≥1 month after ECS and for ≥6 months after PES. RESULTS: At 5 years follow-up, no significant differences were found in TVF (ECS 24% vs. PES 29%, risk difference 95% confidence interval (RDCI) -17.3% to 7.4%). Between 2 and 5 years after the index procedure, low numbers of TVF were observed in ECS compared with PES (ECS 4% vs. PES 16%, RDCI -20.8% to -2.3%). There was no definite stent thrombosis in ECS compared with four patients in the PES group. CONCLUSION: This is the first randomized study providing very long-term clinical efficacy and safety of the ECS in lesions carrying a high risk of restenosis. At 5 years follow-up, TVF rates in ECS group are numerically lower compared with PES due to an increase of events between 2 and 5 years after the index procedure.


Assuntos
Fármacos Cardiovasculares/administração & dosagem , Reestenose Coronária/prevenção & controle , Estenose Coronária/cirurgia , Vasos Coronários/cirurgia , Stents Farmacológicos , Células Progenitoras Endoteliais/patologia , Paclitaxel/administração & dosagem , Intervenção Coronária Percutânea/instrumentação , Fármacos Cardiovasculares/efeitos adversos , Angiografia Coronária , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Reestenose Coronária/patologia , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/patologia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Humanos , Paclitaxel/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Projetos Piloto , Inibidores da Agregação Plaquetária/administração & dosagem , Estudos Prospectivos , Desenho de Prótese , Reepitelização , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
14.
Catheter Cardiovasc Interv ; 90(2): E31-E37, 2017 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-28145609

RESUMO

BACKGROUND: Patients presenting with acute coronary syndrome (ACS) are at increased risk of complications after percutaneous coronary intervention with stent placement compared to patients with stable angina (SA) treated in an elective setting. The novel pro-healing COMBO stent is a bio-engineered drug eluting stent designed to promote vessel healing. Therefore, the stent may reduce this difference in clinical outcomes between elective and ACS-patients and prevent late stent thrombosis. METHODS AND RESULTS: The European, prospective, multicenter, 1000 all-comers patient REMEDEE registry evaluates clinical outcomes after COMBO stent placement in ACS- and elective patients. The primary endpoint at 12 months is target lesion failure (TLF), a composite of cardiac death, target-vessel myocardial infarction and target lesion revascularization. A total of 49.9% (n = 498) of patients presented with acute coronary syndrome. TLF was 7.1% in ACS patients, definite and probable stent thrombosis was observed in 0.5% of ACS patients and in all within 9 days post stenting. We found no significant difference in TLF between ACS and non-ACS patients and a low overall rate of TLF. CONCLUSIONS: The COMBO stent is a safe and efficient device for patients presenting with ACS. Low ST rate and only early stent thrombosis were observed. © 2017 Wiley Periodicals, Inc.


Assuntos
Síndrome Coronariana Aguda/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/mortalidade , Idoso , Trombose Coronária/etiologia , Trombose Coronária/prevenção & controle , Quimioterapia Combinada , Europa (Continente) , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/prevenção & controle , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Inibidores da Agregação Plaquetária/administração & dosagem , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
15.
Catheter Cardiovasc Interv ; 83(2): 203-9, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22508617

RESUMO

OBJECTIVES: To describe clinical outcome after percutaneous coronary intervention (PCI) for acute coronary syndrome (ACS) due to graft failure. BACKGROUND: Limited data are available on outcome after PCI for graft failure-induced ACS in the drug-eluting stent (DES) era. METHODS: Patients were identified who underwent PCI either with DES or BMS for ACS due to graft failure between January 2003 and December 2008. Follow-up was performed at 1 year and April 2011. The primary endpoint was the composite of death, myocardial infarction (MI), or target vessel revascularization (TVR). Kaplan-Meier estimates were calculated at 1 and 5-year follow-up. Predictors were identified by backward selection in Cox proportional hazards models. RESULTS: A total of 92 patients underwent PCI, of which 77 were treated with bare metal stents (BMS) and 15 with DES. Patient and procedural characteristics were similar in both groups. Mean follow-up was 3.2 years. Five-year composite event rate was 65.9% after BMS vs. 43.4% after DES implantation (P = 0.17). Individual endpoints were comparable in both groups. Recurrence of angina, hospitalization, and repeat interventions were similar. After multivariable adjustment, the use of DES was not associated with a significant reduction in the primary endpoint (HR = 0.44, 0.18-1.04, p = 0.06). CONCLUSION: In patients presenting with ACS due to acute graft failure, long-term outcomes remain poor. In a nonrandomized comparison with BMS, DES use was not associated with significant improved long-term clinical outcomes.


Assuntos
Síndrome Coronariana Aguda/terapia , Ponte de Artéria Coronária/efeitos adversos , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Metais , Intervenção Coronária Percutânea/instrumentação , Stents , Síndrome Coronariana Aguda/diagnóstico , Síndrome Coronariana Aguda/etiologia , Síndrome Coronariana Aguda/mortalidade , Idoso , Idoso de 80 Anos ou mais , Ponte de Artéria Coronária/mortalidade , Doença da Artéria Coronariana/mortalidade , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Modelos de Riscos Proporcionais , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Falha de Tratamento
16.
Eur Heart J Case Rep ; 8(4): ytae153, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38645675

RESUMO

Background: We present a case of a pregnant patient with recurrent angina, in which her symptoms were initially attributed to coronary artery spasm. However, during follow-up, she was diagnosed as having pheochromocytoma, a rare neuroendocrine tumour. Case summary: The 35-year-old patient was admitted to the hospital because of chest pain and elevated cardiac troponins after the use of MDMA. Physical examination, electrocardiogram, echocardiography, coronary angiogram, and cardiac MRI were normal. Symptoms were attributed to coronary spasm, and a calcium antagonist was started. Ten months later, when 36 weeks pregnant, her symptoms returned. One week later, the patient was readmitted to the hospital with signs of acute left ventricular (LV) failure, highly elevated troponins, and severe global LV dysfunction. Urgent section caesarean was performed due to maternal morbidity and foetal tachycardia. During section, flushes and marked variability in blood pressure were noted. Laboratory metanephrines testing was performed. LV function recovered within 3 days without any therapeutic intervention. However, chest pain reoccurred, now accompanied with headaches, malignant hypertension, and accelerated idiopathic ventricular rhythms. (Nor)metanephrines tests were positive. A solid lesion in the right adrenal on CT scan confirmed the diagnosis of pheochromocytoma. Fluid repletion and alpha-blocker therapy were started. Due to persistent symptoms, urgent laparoscopic adrenalectomy was performed. Hereafter, the patient remained without symptoms. Discussion: A pheochromocytoma may present with recurrent angina and can result in a catecholamine-induced cardiomyopathy. It is important to timely recognize this diagnosis in order to minimize morbidity and mortality.

17.
JACC Case Rep ; 29(13): 102382, 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38840821

RESUMO

We present 2 patients with angina with no obstructive coronary artery disease and concomitant myocardial bridging. Despite maximal tolerated pharmacotherapy, symptoms remained. Invasive anatomical and hemodynamic assessment identified myocardial bridging as a contributing cause of angina. Following heart team discussion, both patients underwent successful coronary artery unroofing of the left anterior descending artery.

18.
Int J Cardiol ; 399: 131637, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38065322

RESUMO

BACKGROUND: International guidelines for the management of valvular heart disease recommend frailty assessment prior to Transcatheter Aortic Valve Implantation (TAVI), however there is no consensus how to assess frailty. We investigated whether frailty status assessed with the Edmonton Frail Scale (EFS, range 0-17 points) relates to length of stay (LOS), short- and long-term mortality and adverse outcomes after TAVI. METHODS: In this study we included 357 patients between April 2016 till December 2018. EFS was assessed at baseline. Patients were classified into low (0-3), intermediate (4-7) or high frailty status (8-17). LOS was defined as the number of days between admission and discharge. Mortality data were obtained up to four years after TAVI. Adverse events were defined by Valve Academic Research Consortium (VARC)-2 criteria and collected <30 days after TAVI. RESULTS: Patients with higher frailty status had longer median LOS (days (IQR): low 5 (3), intermediate 6 (4) and high 7 (5), p < 0.001) and higher mortality: low vs intermediate vs high at 30 days 0.5%, 2.2%, 7.0% (p = 0.050), 1 year 3.7%, 10.0%, 15.2% (p = 0.052), 2 years 9.2%, 17.8%, 31.7% (p = 0.003), 3 years 17.2%, 24.0, 47.0% (p = 0.001) and 4 years 19.6%, 30.8%, 55.6% (p < 0.001). Frail patients received more often a pacemaker (2.6%, 6.6%, 13.5%, p = 0.048). CONCLUSION: In clinical practice, the EFS is a useful tool to screen for frailty in TAVI patients. This tool may possibly be expanded to determine benefit versus harm-risk in these patients and whether specific pre-procedurally interventions are needed in order to reduce mortality.


Assuntos
Estenose da Valva Aórtica , Fragilidade , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Substituição da Valva Aórtica Transcateter/efeitos adversos , Fragilidade/diagnóstico , Tempo de Internação , Idoso Fragilizado , Medição de Risco , Fatores de Risco , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Valva Aórtica/cirurgia , Resultado do Tratamento
20.
Am J Cardiol ; 217: 49-58, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38417650

RESUMO

Coronary endothelial dysfunction (CED) and coronary artery spasm (CAS) are causes of angina with no obstructive coronary arteries in patients. Both can be diagnosed by invasive coronary function testing (ICFT) using acetylcholine (ACh). This study aimed to evaluate the diagnostic yield of a 3-minute ACh infusion as compared with a 1-minute ACh bolus injection protocol in testing CED and CAS. We evaluated 220 consecutive patients with angina and no obstructive coronary arteries who underwent ICFT using continuous Doppler flow measurements. Per protocol, 110 patients were tested using 3-minute infusion, and thereafter 110 patients using 1-minute bolus injections, because of a protocol change. CED was defined as a <50% increase in coronary blood flow or any epicardial vasoconstriction in reaction to low-dose ACh and CAS according to the Coronary Vasomotor Disorders International Study Group (COVADIS) criteria, both with and without T-wave abnormalities, in reaction to high dose ACh. The prevalence of CED was equal in both protocols (78% vs 79%, p = 0.869). Regarding the endotypes of CAS according to COVADIS, the equivocal endotype was diagnosed less often in the 3 vs 1-minute protocol (24% vs 44%, p = 0.004). Including T-wave abnormalities in the COVADIS criteria resulted in a similar diagnostic yield of both protocols. Hemodynamic changes from baseline to the low or high ACh doses were comparable between the protocols for each endotype. In conclusion, ICFT using 3-minute infusion or 1-minute bolus injections of ACh showed a similar diagnostic yield of CED. When using the COVADIS criteria, a difference in the equivocal diagnosis was observed. Including T-wave abnormalities as a diagnostic criterion reclassified equivocal test results into CAS and decreased this difference. For clinical practice, we recommend the inclusion of T-wave abnormalities as a diagnostic criterion for CAS and the 1-minute bolus protocol for practicality.


Assuntos
Acetilcolina , Vasoespasmo Coronário , Humanos , Angiografia Coronária , Vasoespasmo Coronário/diagnóstico , Vasoespasmo Coronário/epidemiologia , Vasoconstrição , Angina Pectoris , Vasos Coronários/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA