Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Eur Radiol ; 31(3): 1471-1481, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32902743

RESUMO

OBJECTIVES: To test the accuracy of clinical pre-test probability (PTP) for prediction of obstructive coronary artery disease (CAD) in a pan-European setting. METHODS: Patients with suspected CAD and stable chest pain who were clinically referred for invasive coronary angiography (ICA) or computed tomography (CT) were included by clinical sites participating in the pilot study of the European multi-centre DISCHARGE trial. PTP of CAD was determined using the Diamond-Forrester (D+F) prediction model initially introduced in 1979 and the updated D+F model from 2011. Obstructive coronary artery disease (CAD) was defined by one at least 50% diameter coronary stenosis by both CT and ICA. RESULTS: In total, 1440 patients (654 female, 786 male) were included at 25 clinical sites from May 2014 until July 2017. Of these patients, 725 underwent CT, while 715 underwent ICA. Both prediction models overestimated the prevalence of obstructive CAD (31.7%, 456 of 1440 patients, PTP: initial D+F 58.9% (28.1-90.6%), updated D+F 47.3% (34.2-59.9%), both p < 0.001), but overestimation of disease prevalence was higher for the initial D+F (p < 0.001). The discriminative ability was higher for the updated D+F 2011 (AUC of 0.73 95% confidence interval [CI] 0.70-0.76 versus AUC of 0.70 CI 0.67-0.73 for the initial D+F; p < 0.001; odds ratio (or) 1.55 CI 1.29-1.86, net reclassification index 0.11 CI 0.05-0.16, p < 0.001). CONCLUSIONS: Clinical PTP calculation using the initial and updated D+F prediction models relevantly overestimates the actual prevalence of obstructive CAD in patients with stable chest pain clinically referred for ICA and CT suggesting that further refinements to improve clinical decision-making are needed. TRIAL REGISTRATION: https://www.clinicaltrials.gov/ct2/show/NCT02400229 KEY POINTS: • Clinical pre-test probability calculation using the initial and updated D+F model overestimates the prevalence of obstructive CAD identified by ICA and CT. • Overestimation of disease prevalence is higher for the initial D+F compared with the updated D+F. • Diagnostic accuracy of PTP assessment varies strongly between different clinical sites throughout Europe.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/epidemiologia , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/epidemiologia , Europa (Continente) , Feminino , Humanos , Masculino , Alta do Paciente , Projetos Piloto , Valor Preditivo dos Testes , Medição de Risco , Fatores de Risco
3.
Eur Radiol ; 30(4): 1997-2009, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31844958

RESUMO

OBJECTIVE: To implement detailed EU cardiac computed tomography angiography (CCTA) quality criteria in the multicentre DISCHARGE trial (FP72007-2013, EC-GA 603266), we reviewed image quality and adherence to CCTA protocol and to the recommendations of invasive coronary angiography (ICA) in a pilot study. MATERIALS AND METHODS: From every clinical centre, imaging datasets of three patients per arm were assessed for adherence to the inclusion/exclusion criteria of the pilot study, predefined standards for the CCTA protocol and ICA recommendations, image quality and non-diagnostic (NDX) rate. These parameters were compared via multinomial regression and ANOVA. If a site did not reach the minimum quality level, additional datasets had to be sent before entering into the final accepted database (FADB). RESULTS: We analysed 226 cases (150 CCTA/76 ICA). The inclusion/exclusion criteria were not met by 6 of the 226 (2.7%) datasets. The predefined standard was not met by 13 of 76 ICA datasets (17.1%). This percentage decreased between the initial CCTA database and the FADB (multinomial regression, 53 of 70 vs 17 of 75 [76%] vs [23%]). The signal-to-noise ratio and contrast-to-noise ratio of the FADB did not improve significantly (ANOVA, p = 0.20; p = 0.09). The CTA NDX rate was reduced, but not significantly (initial CCTA database 15 of 70 [21.4%]) and FADB 9 of 75 [12%]; p = 0.13). CONCLUSION: We were able to increase conformity to the inclusion/exclusion criteria and CCTA protocol, improve image quality and decrease the CCTA NDX rate by implementing EU CCTA quality criteria and ICA recommendations. KEY POINTS: • Failure to meet protocol adherence in cardiac CTA was high in the pilot study (77.6%). • Image quality varies between sites and can be improved by feedback given by the core lab. • Conformance with new EU cardiac CT quality criteria might render cardiac CTA findings more consistent and comparable.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Vasos Coronários/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Reprodutibilidade dos Testes
4.
J Mol Cell Cardiol ; 75: 12-24, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24998410

RESUMO

A decade ago, stem or progenitor cells held the promise of tissue regeneration in human myocardium, with the expectation that these therapies could rescue ischemic myocyte damage, enhance vascular density and rebuild injured myocardium. The accumulated evidence in 2014 indicates, however, that the therapeutic success of these cells is modest and the tissue regeneration involves much more complex processes than cell-related biologics. As the quest for the ideal cell or combination of cells continues, alternative cell types, such as resident cardiac cells, adipose-derived or phenotypic modified stem or progenitor cells have also been applied, with the objective of increasing both the number and the retention of the reparative cells in the myocardium. Two main delivery routes (intracoronary and percutaneous intramyocardial) of stem cells are currently used preferably for patients with recent acute myocardial infarction or ischemic cardiomyopathy. Other delivery modes, such as surgical or intravenous via peripheral veins or coronary sinus have also been utilized with less success. Due to the difficult recruitment of patients within conceivable timeframe into cardiac regenerative trials, meta-analyses of human cardiac cell-based studies have tried to gather sufficient number of subjects to present a statistical compelling statement, reporting modest success with a mean increase of 0.9-6.1% in left ventricular global ejection fraction. Additionally, nearly half of the long-term studies reported the disappearance of the initial benefit of this treatment. Beside further extensive efforts to increase the efficacy of currently available methods, pre-clinical experiments using new techniques such as tissue engineering or exploiting paracrine effect hold promise to regenerate injured human cardiac tissue.


Assuntos
Ensaios Clínicos como Assunto , Isquemia Miocárdica/terapia , Transplante de Células-Tronco , Coração/fisiopatologia , Humanos , Isquemia Miocárdica/fisiopatologia , Regeneração , Resultado do Tratamento
6.
Stem Cell Rev Rep ; 7(3): 616-23, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21153508

RESUMO

The aim of the present study was to investigate the changes in absolute myocardial blood flow (AMF) after intracoronary injections of mesenchymal SC (MSC) and compared to controls in closed-chest reperfused acute myocardial infarction (AMI) in pigs. Male MSCs, transiently transfected with Luciferase (Luc-MSC) were delivered (9.7 ± 1.2 x 10(6)) intracoronary in the open infarct-related artery one-week post-AMI in female pigs (group MSC), while saline was injected with the same injection rate in controls (group C). The AMF was measured immediately after, and 3, 12 and 24 h post-intracoronary Luc-MSC or saline injections. In vitro bioluminescence images and quantitative real-time TaqMan PCR measurements were performed to quantify the sex-mismatched MSCs. No difference between the groups was observed regarding the weight, heart rate, blood pressure and global ejection fraction 1-week post-AMI. The baseline AMF were similar in the groups (61.3 ± 15. vs 61.1 ± 12.0 ml/min). AMF was decreased significantly immediately after intracoronary MSC delivery (42.0 ± 12.4 vs 57.7 ± 15.7 ml/min p = 0.013), and remained low at 3 h (40.9 ± 13.4 vs 55.8 ± 4.9 ml/min, p = 0.004), 12 h (43.0 ± 3.7 vs 57.8 ± 5.4 ml/min, p = 0.001) with incomplete recovery at 24 h (47.2 ± 5.5 vs 62.1 ± 14.1 ml/min, p = 0.038) as compared to controls, respectively. In vitro bioluminescence displayed transfected Luc-MSCs along the proximal and mid part of the LAD, with limited number (295 ± 101 sry copied/million cardiac cells) of Y-chromosome-MSCs in the infarcted area. Intracoronary injection of SCs results in immediate decrease of AMF, with delayed recovery. The delivery of the SC into the injured myocardium might be hindered by the altered coronary pressure and flow conditions.


Assuntos
Circulação Coronária/fisiologia , Transplante de Células-Tronco Mesenquimais , Células-Tronco Mesenquimais/citologia , Infarto do Miocárdio/terapia , Fluxo Sanguíneo Regional , Animais , Terapia Baseada em Transplante de Células e Tecidos/métodos , Feminino , Hemodinâmica , Humanos , Masculino , Células-Tronco Mesenquimais/fisiologia , Miocárdio/citologia , Distribuição Aleatória , Suínos
7.
J Cardiovasc Transl Res ; 3(2): 114-21, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20560024

RESUMO

We have investigated the effect of stem cell delivery on the release of hypoxia-inducible factor 1 alpha (HIF-1alpha) in peripheral circulation and myocardium in experimental myocardial ischemia. Closed-chest, reperfused myocardial infarction (MI) was created in domestic pigs. Porcine mesenchymal stem cells (MSCs) were cultured and delivered (9.8 +/- 1.2 x 10(6)) either percutaneously NOGA-guided transendocardially (Group IM) or intracoronary (Group IC) 22 +/- 4 days post-MI. Pigs without MSC delivery served as sham control (Group S). Plasma HIF-1alpha was measured at baseline, immediately post- and at follow-up (FUP; 2 h or 24 h) post-MSC delivery by ELISA kit. Myocardial HIF-1alpha expression of infarcted, normal myocardium, or border zone was determined by Western blot. Plasma level of HIF-1alpha increased immediately post-MI (from 278 +/- 127 to 631 +/- 375 pg/ml, p < 0.05). Cardiac delivery of MSCs elevated the plasma levels of HIF-1alpha significantly (p < 0.05) in groups IC and IM immediately post-MSC delivery, and returned to baseline level at FUP, without difference between the groups IC and IM. The myocardial tissue HIF-1alpha expression in the infarcted area was higher in Group IM than in Group IC or S (1,963 +/- 586 vs. 1,307 +/- 392 vs. 271 +/- 110 activity per square millimeter, respectively, p < 0.05), while the border zone contained similarly lower level of HIF-1alpha, but still significantly higher as compared with Group S. Trend towards increase in myocardial expression of HIF-1alpha was measured in Group IM at 24 h, in contrast to Group IC. In conclusion, both stem cell delivery modes increase the systemic and myocardial level of HIF-1alpha. Intramyocardial delivery of MSC seems to trigger the release of angiogenic HIF-1alpha more effectively than does intracoronary delivery.


Assuntos
Subunidade alfa do Fator 1 Induzível por Hipóxia/metabolismo , Transplante de Células-Tronco Mesenquimais , Infarto do Miocárdio/cirurgia , Miocárdio/metabolismo , Animais , Western Blotting , Células Cultivadas , Modelos Animais de Doenças , Ensaio de Imunoadsorção Enzimática , Subunidade alfa do Fator 1 Induzível por Hipóxia/sangue , Injeções , Infarto do Miocárdio/metabolismo , Infarto do Miocárdio/patologia , Infarto do Miocárdio/fisiopatologia , Miocárdio/patologia , Sus scrofa , Fatores de Tempo , Regulação para Cima , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA