Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
1.
Eur Radiol ; 33(9): 6557-6568, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37014405

RESUMO

OBJECTIVE: To accurately estimate liver PDFF from chemical shift-encoded (CSE) MRI using a deep learning (DL)-based Multi-Decoder Water-Fat separation Network (MDWF-Net), that operates over complex-valued CSE-MR images with only 3 echoes. METHODS: The proposed MDWF-Net and a U-Net model were independently trained using the first 3 echoes of MRI data from 134 subjects, acquired with conventional 6-echoes abdomen protocol at 1.5 T. Resulting models were then evaluated using unseen CSE-MR images obtained from 14 subjects that were acquired with a 3-echoes CSE-MR pulse sequence with a shorter duration compared to the standard protocol. Resulting PDFF maps were qualitatively assessed by two radiologists, and quantitatively assessed at two corresponding liver ROIs, using Bland Altman and regression analysis for mean values, and ANOVA testing for standard deviation (STD) (significance level: .05). A 6-echo graph cut was considered ground truth. RESULTS: Assessment of radiologists demonstrated that, unlike U-Net, MDWF-Net had a similar quality to the ground truth, despite it considered half of the information. Regarding PDFF mean values at ROIs, MDWF-Net showed a better agreement with ground truth (regression slope = 0.94, R2 = 0.97) than U-Net (regression slope = 0.86, R2 = 0.93). Moreover, ANOVA post hoc analysis of STDs showed a statistical difference between graph cuts and U-Net (p < .05), unlike MDWF-Net (p = .53). CONCLUSION: MDWF-Net showed a liver PDFF accuracy comparable to the reference graph cut method, using only 3 echoes and thus allowing a reduction in the acquisition times. CLINICAL RELEVANCE STATEMENT: We have prospectively validated that the use of a multi-decoder convolutional neural network to estimate liver proton density fat fraction allows a significant reduction in MR scan time by reducing the number of echoes required by 50%. KEY POINTS: • Novel water-fat separation neural network allows for liver PDFF estimation by using multi-echo MR images with a reduced number of echoes. • Prospective single-center validation demonstrated that echo reduction leads to a significant shortening of the scan time, compared to standard 6-echo acquisition. • Qualitative and quantitative performance of the proposed method showed no significant differences in PDFF estimation with respect to the reference technique.


Assuntos
Fígado , Água , Humanos , Estudos Prospectivos , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Abdome , Redes Neurais de Computação , Reprodutibilidade dos Testes
2.
Eur Radiol ; 30(2): 1020-1030, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31673837

RESUMO

OBJECTIVES: To evaluate the diagnostic performance of contrast-enhanced CT vs. MRI with extracellular contrast agents (EC-MRI) vs. MRI with gadoxetic acid (EOB-MRI) for HCC detection in patients with liver cirrhosis using liver explant as the reference. The additional value of hepatobiliary phase (HBP) post Gadoxetic acid was also assessed. METHODS: Two-hundred seventy-seven consecutive patients who underwent liver transplantation over a 9 year period and imaging within 90 days of were retrospectively included. Imaging consisted in CT (n = 100), EC-MRI (n = 77) and EOB-MRI (n = 100), the latter subdivided into dynamic EOB-MRI and full EOB-MRI (dynamic+HBP). Three radiologists retrospectively categorized lesions ≥ 1 cm using the LI-RADSv2017 algorithm. Dynamic EOB-MRI was re-evaluated with the addition of HBP. Results were correlated with explant pathology. RESULTS: Pathology demonstrated 265 HCCs (mean size 2.1 ± 1.4 cm) in 177 patients. Per-patient sensitivities were 86.3% for CT, 89.5% for EC-MRI, 92.8% for dynamic EOB-MRI and 95.2% for full EOB-MRI (pooled reader data), with a significant difference between CT and dynamic/full EOB-MRI (p = 0.032/0.002), and between EC-MRI and full EOB-MRI (p = 0.047). Per-lesion sensitivities for CT, EC-MRI, dynamic EOB-MRI and full EOB-MRI were 59.5%,78.5%,69.7% and 76.8%, respectively, with a significant difference between MRI groups and CT (p-range:0.001-0.04), and no difference between EC-MRI and dynamic EOB-MRI (p = 0.949). For HCCs 1-1.9 cm, sensitivities were 34.4%, 64.6%, 57.3% and 67.3%, respectively, with all MRI groups significantly superior to CT (p ≤ 0.01) and full EOB-MRI superior to dynamic EOB-MRI (p = 0.002). CONCLUSIONS: EOB-MRI outperforms CT and EC-MRI for per-patient HCC detection sensitivity, and is equivalent to EC-MRI for per-lesion sensitivity. MRI methods outperform CT for detection of HCCs 1-1.9 cm. KEY POINTS: • MRI is superior to CT for HCC detection in patients with liver cirrhosis. • EOB-MRI outperforms CT and MRI using extracellular contrast agents (EC-MRI) for per-patient HCC detection sensitivity, and is equivalent to EC-MRI for per-lesion sensitivity. • The addition of hepatobiliary phase images improves HCC detection when using gadoxetic acid.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Cirrose Hepática/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Adulto , Idoso , Carcinoma Hepatocelular/etiologia , Carcinoma Hepatocelular/patologia , Carcinoma Hepatocelular/cirurgia , Meios de Contraste , Reações Falso-Positivas , Feminino , Gadolínio DTPA , Humanos , Cirrose Hepática/complicações , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/cirurgia , Transplante de Fígado , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos
3.
Eur Radiol ; 30(7): 3759-3769, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32086577

RESUMO

OBJECTIVE: To assess the value of qualitative and quantitative MRI radiomics features for noninvasive prediction of immuno-oncologic characteristics and outcomes of hepatocellular carcinoma (HCC). METHODS: This retrospective, IRB-approved study included 48 patients with HCC (M/F 35/13, mean age 60y) who underwent hepatic resection or transplant within 4 months of abdominal MRI. Qualitative imaging traits, quantitative nontexture related and texture features were assessed in index lesions on contrast-enhanced T1-weighted and diffusion-weighted images. The association of imaging features with immunoprofiling and genomics features was assessed using binary logistic regression and correlation analyses. Binary logistic regression analysis was also employed to analyse the association of radiomics, histopathologic and genomics features with radiological early recurrence of HCC at 12 months. RESULTS: Qualitative (r = - 0.41-0.40, p < 0.042) and quantitative (r = - 0.52-0.45, p < 0.049) radiomics features correlated with immunohistochemical cell type markers for T-cells (CD3), macrophages (CD68) and endothelial cells (CD31). Radiomics features also correlated with expression of immunotherapy targets PD-L1 at protein level (r = 0.41-0.47, p < 0.029) as well as PD1 and CTLA4 at mRNA expression level (r = - 0.48-0.47, p < 0.037). Finally, radiomics features, including tumour size, showed significant diagnostic performance for assessment of early HCC recurrence (AUC 0.76-0.80, p < 0.043), while immunoprofiling and genomic features did not (p = 0.098-0929). CONCLUSIONS: MRI radiomics features may serve as noninvasive predictors of HCC immuno-oncological characteristics and tumour recurrence and may aid in treatment stratification of HCC patients. These results need prospective validation. KEY POINTS: • MRI radiomics features showed significant associations with immunophenotyping and genomics characteristics of hepatocellular carcinoma. • Radiomics features, including tumour size, showed significant associations with early hepatocellular carcinoma recurrence after resection.


Assuntos
Carcinoma Hepatocelular/diagnóstico , Imunidade Celular , Neoplasias Hepáticas/diagnóstico , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Carcinoma Hepatocelular/imunologia , Células Endoteliais/imunologia , Células Endoteliais/patologia , Feminino , Humanos , Neoplasias Hepáticas/imunologia , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia , Valor Preditivo dos Testes , Estudos Prospectivos , Estudos Retrospectivos
4.
J Magn Reson Imaging ; 47(6): 1552-1561, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29193508

RESUMO

BACKGROUND: Multiparametric magnetic resonance imaging (mpMRI) combining different techniques such as MR elastography (MRE) has emerged as a noninvasive approach to diagnose and stage liver fibrosis with high accuracy allowing for anatomical and functional information. PURPOSE: To assess the diagnostic performance of mpMRI including qualitative and quantitative assessment of MRE, liver surface nodularity (LSN) measurement, hepatic enhancement ratios postgadoxetic acid, and serum markers (APRI, FIB-4) for the detection of liver fibrosis. STUDY TYPE: IRB-approved retrospective. SUBJECTS: Eighty-three adult patients. FIELD STRENGTH/SEQUENCE: 1.5T and 3.0T MR systems. MRE and T1 -weighted postgadoxetic acid sequences. ASSESSMENT: Two independent observers analyzed qualitative color-coded MRE maps on a scale of 0-3. Regions of interest were drawn to measure liver stiffness on MRE stiffness maps and on pre- and postcontrast T1 -weighted images to measure hepatic enhancement ratios. Software was used to generate LSN measurements. Histopathology was used as the reference standard for diagnosis of liver fibrosis in all patients. STATISTICAL TESTS: A multivariable logistic analysis was performed to identify independent predictors of liver fibrosis. Receiver operating characteristic (ROC) analysis evaluated the performance of each imaging technique for detection of fibrosis, in comparison with serum markers. RESULTS: Liver stiffness measured with MRE provided the strongest correlation with histopathologic fibrosis stage (r = 0.74, P < 0.001), and the highest diagnostic performance for detection of stages F2-F4, F3-F4, and F4 (areas under the curve [AUCs] of 0.87, 0.91, and 0.89, respectively, P < 0.001) compared to other methods. Qualitative assessment of MRE maps showed fair to good accuracy for detection of fibrosis (AUC range 0.76-0.84). Multivariable logistic analysis identified liver stiffness and FIB-4 as independent predictors of fibrosis with AUCs of 0.90 (F2-F4), 0.93 (F3-F4) and 0.92 (F4) when combined. DATA CONCLUSION: Liver stiffness measured with MRE showed the best performance for detection of liver fibrosis compared to LSN and gadoxetic acid uptake, with slight improvement when combined with FIB-4. LEVEL OF EVIDENCE: 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:1552-1561.


Assuntos
Técnicas de Imagem por Elasticidade , Gadolínio DTPA/farmacocinética , Cirrose Hepática/diagnóstico por imagem , Imageamento por Ressonância Magnética , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Feminino , Humanos , Cirrose Hepática/sangue , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Variações Dependentes do Observador , Curva ROC , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
5.
J Magn Reson Imaging ; 48(4): 1091-1103, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29638020

RESUMO

BACKGROUND: Portal hypertension (PH), defined by hepatic venous pressure gradient (HVPG) ≥5 mmHg and clinically significant PH, defined by HVPG ≥10 mmHg, are complications of chronic liver disease. PURPOSE: To assess the diagnostic performance of MR elastography (MRE) and dynamic contrast-enhanced MRI (DCE-MRI) of the liver and spleen for the prediction of PH and clinically significant PH, in comparison with a qualitative PH imaging scoring system. STUDY TYPE: IRB-approved prospective study. POPULATION: In all, 34 patients with chronic liver disease who underwent HVPG measurement. FIELD STRENGTH/SEQUENCE: 1.5/3T examination including 2D-GRE MRE (n = 33) and DCE-MRI of the liver/spleen (n = 28). ASSESSMENT: Liver and spleen stiffness were calculated from elastogram maps. DCE-MRI was analyzed using model-free parameters and pharmacokinetic modeling. Two observers calculated qualitative PH imaging scores based on routine images. STATISTICAL TESTS: Imaging parameters were correlated with HVPG. Receiver operating characteristic (ROC) analysis was performed for prediction of PH and clinically significant PH. RESULTS: There were significant correlations between DCE-MRI parameters (liver time-to-peak, r = 0.517 / P = 0.006, liver distribution volume, r = 0.494 / P = 0.009, liver upslope, r = -0.567 / P = 0.002), liver stiffness (r = 0.478 / P = 0.016), PH imaging score (r = 0.441 / P = 0.009), and HVPG. ROC analysis provided significant area under the ROC (AUROCs) for PH (liver upslope 0.765, liver stiffness 0.809, spleen volume/diameter 0.746-0.731, PH imaging score 0.756) and for clinically significant PH (liver and spleen perfusion parameters 0.733-0.776, liver stiffness 0.742, PH imaging score 0.742). The ratio of liver stiffness to liver upslope had the highest AUROC for diagnosing PH (0.903) and clinically significant PH (0.785). DATA CONCLUSION: These preliminary results suggest that the combination of liver stiffness and perfusion metrics provide excellent accuracy for diagnosing PH, and fair accuracy for clinically significant PH. Combined MRE and DCE-MRI outperformed qualitative imaging scores for prediction of PH. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;48:1091-1103.


Assuntos
Técnicas de Imagem por Elasticidade , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética , Baço/diagnóstico por imagem , Adulto , Idoso , Índice de Massa Corporal , Meios de Contraste , Doença Hepática Terminal/diagnóstico por imagem , Feminino , Veias Hepáticas/diagnóstico por imagem , Humanos , Hipertensão Portal/diagnóstico por imagem , Cirrose Hepática/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Pressão na Veia Porta , Estudos Prospectivos , Curva ROC , Radiologia
6.
Eur Radiol ; 28(5): 2047-2057, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29234913

RESUMO

OBJECTIVE: To correlate qualitative and quantitative diffusion weighted imaging (DWI) characteristics of intrahepatic cholangiocarcinoma (ICC) with histopathologic tumour grade and fibrosis content. METHODS: Fifty-one patients (21M/30F; mean age 61y) with ICC and MRI including DWI were included in this IRB-approved multicentre retrospective study. Qualitative tumour features were assessed. Tumour apparent diffusion coefficient (ADC) mean, minimum, and normalized (nADCliver) values were computed. Tumour grade [well(G1), moderately(G2), or poorly differentiated(G3)] and tumour fibrosis content [minimal(1), moderate(2), or abundant(3)] were categorized pathologically. Imaging findings and ADC values were compared with pathologic measures. Utility of ADC values for predicting tumour grade was assessed using ROC analysis. RESULTS: 51 ICCs (mean size 6.5±1.1 cm) were assessed. 33/51(64%) of ICCs demonstrated diffuse hyperintensity and 15/51(29%) demonstrated target appearance on DWI. Infiltrative morphology (p=0.02) and tumour size (p=0.04) were associated with G3. ADCmean and nADCmean of G3 (1.32±0.47x10-3 mm2/sec and 0.97±0.95) were lower than G1+G2 (1.57±0.39x10-3 mm2/sec and 1.24±0.49; p=0.03 and p=0.04). ADCmean and nADCmean were inversely correlated with tumour grade (p<0.025). No correlation was found between ADC and tumour fibrosis content. AUROC, sensitivity and specificity of nADCmean for G3 versus G1+G2 were 0.71, 89.5% and 55.5%. CONCLUSION: ADC quantification has reasonable accuracy for predicting ICC grade. KEY POINTS: • ADC quantification was useful for predicting ICC tumour grade. • Infiltrative tumour morphology and size were associated with poorly differentiated ICCs. • ADC values depended more on ICC tumour grade than fibrosis content. • Ability to predict ICC tumour grade non-invasively could impact patient management.


Assuntos
Neoplasias dos Ductos Biliares/patologia , Colangiocarcinoma/diagnóstico por imagem , Colangiocarcinoma/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias dos Ductos Biliares/diagnóstico por imagem , Ductos Biliares/diagnóstico por imagem , Ductos Biliares/patologia , Estudos de Avaliação como Assunto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Curva ROC , Estudos Retrospectivos , Sensibilidade e Especificidade
7.
J Hepatol ; 67(6): 1213-1221, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-28823713

RESUMO

BACKGROUND AND AIMS: This study evaluates the performance of various magnetic resonance imaging (MRI) response criteria for the prediction of complete pathologic necrosis (CPN) of hepatocellular carcinoma (HCC) post locoregional therapy (LRT) using explant pathology as a reference. METHODS: We included 61 patients (male/female 46/15; mean age 60years) who underwent liver transplantation after LRT with transarterial chemoembolization plus radiofrequency or microwave ablation (n=56), or 90Yttrium radioembolization (n=5). MRI was performed <90days before liver transplantation. Three independent readers assessed the following criteria: RECIST, EASL, modified RECIST (mRECIST), percentage of necrosis on subtraction images, and diffusion-weighted imaging (DWI), both qualitative (signal intensity) and quantitative (apparent diffusion coefficient [ADC]). The degree of necrosis was retrospectively assessed at histopathology. Intraclass correlation coefficient (ICC) and Cohen's kappa were used to assess inter-reader agreement. Logistic regression and receiver operating characteristic analyses were used to determine imaging predictors of CPN. Pearson correlation was performed between imaging criteria and pathologic degree of tumor necrosis. RESULTS: A total of 97HCCs (mean size 2.3±1.3cm) including 28 with CPN were evaluated. There was excellent inter-reader agreement (ICC 0.77-0.86, all methods). EASL, mRECIST, percentage of necrosis and qualitative DWI were all significant (p<0.001) predictors of CPN, while RECIST and ADC were not. EASL, mRECIST and percentage of necrosis performed similarly (area under the curves [AUCs] 0.810-0.815) while the performance of qualitative DWI was lower (AUC 0.622). Image subtraction demonstrated the strongest correlation (r=0.71-0.72, p<0.0001) with pathologic degree of tumor necrosis. CONCLUSIONS: EASL/mRECIST criteria and image subtraction have excellent diagnostic performance for predicting CPN in HCC treated with LRT, with image subtraction correlating best with pathologic degree of tumor necrosis. Thus, MR image subtraction is recommended for assessing HCC response to LRT. LAY SUMMARY: The assessment of hepatocellular carcinoma (HCC) tumor necrosis after locoregional therapy is essential for additional treatment planning and estimation of outcome. In this study, we assessed the performance of various magnetic resonance imaging (MRI) response criteria (RECIST, mRECIST, EASL, percentage of necrosis on subtraction images, and diffusion-weighted imaging) for the prediction of complete pathologic necrosis of HCC post locoregional therapy on liver explant. Patients who underwent liver transplantation after locoregional therapy were included in this retrospective study. All patients underwent routine liver MRI within 90days of liver transplantation. EASL/mRECIST criteria and image subtraction had excellent diagnostic performance for predicting complete pathologic necrosis in treated HCC, with image subtraction correlating best with pathologic degree of tumor necrosis.


Assuntos
Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica , Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias Hepáticas/terapia , Idoso , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Feminino , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Transplante de Fígado , Masculino , Pessoa de Meia-Idade , Necrose , Estudos Retrospectivos
8.
Radiology ; 284(2): 401-412, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28045604

RESUMO

Purpose To assess the determinants of technical failure of magnetic resonance (MR) elastography of the liver in a large single-center study. Materials and Methods This retrospective study was approved by the institutional review board. Seven hundred eighty-one MR elastography examinations performed in 691 consecutive patients (mean age, 58 years; male patients, 434 [62.8%]) in a single center between June 2013 and August 2014 were retrospectively evaluated. MR elastography was performed at 3.0 T (n = 443) or 1.5 T (n = 338) by using a gradient-recalled-echo pulse sequence. MR elastography and anatomic image analysis were performed by two observers. Additional observers measured liver T2* and fat fraction. Technical failure was defined as no pixel value with a confidence index higher than 95% and/or no apparent shear waves imaged. Logistic regression analysis was performed to assess potential predictive factors of technical failure of MR elastography. Results The technical failure rate of MR elastography at 1.5 T was 3.5% (12 of 338), while it was higher, 15.3% (68 of 443), at 3.0 T. On the basis of univariate analysis, body mass index, liver iron deposition, massive ascites, use of 3.0 T, presence of cirrhosis, and alcoholic liver disease were all significantly associated with failure of MR elastography (P < .004); but on the basis of multivariable analysis, only body mass index, liver iron deposition, massive ascites, and use of 3.0 T were significantly associated with failure of MR elastography (P < .004). Conclusion The technical failure rate of MR elastography with a gradient-recalled-echo pulse sequence was low at 1.5 T but substantially higher at 3.0 T. Massive ascites, iron deposition, and high body mass index were additional independent factors associated with failure of MR elastography of the liver with a two-dimensional gradient-recalled-echo pulse sequence. © RSNA, 2017.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Hepatopatias/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Testes de Função Hepática , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
9.
J Magn Reson Imaging ; 46(3): 837-849, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28092414

RESUMO

PURPOSE: To quantify Tofts model (TM) and shutter-speed model (SSM) perfusion parameters in prostate cancer (PCa) and noncancerous peripheral zone (PZ) and to compare the diagnostic performance of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) to Prostate Imaging and Reporting and Data System (PI-RADS) classification for the assessment of PCa aggressiveness. MATERIALS AND METHODS: Fifty PCa patients (mean age 60 years old) who underwent MRI at 3.0T followed by prostatectomy were included in this Institutional Review Board-approved retrospective study. DCE-MRI parameters (Ktrans , ve , kep [TM&SSM] and intracellular water molecule lifetime τi [SSM]) were determined in PCa and PZ. Differences in DCE-MRI parameters between PCa and PZ, and between models were assessed using Wilcoxon signed-rank tests. Receiver operating characteristic (ROC) analysis for differentiation between PCa and PZ was performed for individual and combined DCE-MRI parameters. Diagnostic performance of DCE-MRI parameters for identification of aggressive PCa (Gleason ≥8, grade group [GG] ≥3 or pathology stage pT3) was assessed using ROC analysis and compared with PI-RADSv2 scores. RESULTS: DCE-MRI parameters were significantly different between TM and SSM and between PZ and PCa (P < 0.037). Diagnostic performances of TM and SSM for differentiation of PCa from PZ were similar (highest AUC TM: Ktrans +kep 0.76, SSM: τi +kep 0.80). PI-RADS outperformed TM and SSM DCE-MRI for identification of Gleason ≥8 lesions (AUC PI-RADS: 0.91, highest AUC DCE-MRI: Ktrans +τi SSM 0.61, P = 0.002). The diagnostic performance of PI-RADS and DCE-MRI for identification of GG ≥3 and pT3 PCa was not significantly different (P > 0.213). CONCLUSION: SSM DCE-MRI did not increase the diagnostic performance of DCE-MRI for PCa characterization. PI-RADS outperformed both TM and SSM DCE-MRI for identification of aggressive cancer. LEVEL OF EVIDENCE: 3 Technical Efficacy: Stage 2 J. MAGN. RESON. IMAGING 2017;46:837-849.


Assuntos
Meios de Contraste , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Invasividade Neoplásica , Próstata/diagnóstico por imagem , Próstata/patologia , Reprodutibilidade dos Testes , Estudos Retrospectivos
10.
J Magn Reson Imaging ; 44(6): 1432-1441, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27227756

RESUMO

PURPOSE: To assess the value of apparent diffusion coefficient (ADC) measured with diffusion-weighted imaging (DWI) and enhancement ratios (ER) measured with contrast-enhanced T1-weighted imaging (CE-T1WI) for the characterization of histopathologic tumor grade of neuroendocrine tumor liver metastases (NETLM). MATERIALS AND METHODS: Twenty-two patients with pathology-proven NETLM and pretreatment 1.5 Tesla (T) and 3T MRI including DWI were included in this Institutional Review Board-approved retrospective study. ADC histogram parameters, including mean, minimum (min), skewness, and kurtosis as well as ER, were computed for all lesions. Tumor grading was based on the World Health Organization 2010 classification. Kruskal-Wallis and Mann-Whitney test were used to assess for differences in ADC and ER between different tumor grades. MRI parameters were correlated with pathologic findings using Spearman correlation test. Receiver operating characteristic analysis was performed to determine optimum thresholds for predicting tumor grade. RESULTS: Forty-eight NETLM (mean size 3.5 cm) were analyzed with the following grade distribution: G1 (n = 25), G2 (n = 16), and G3 (n = 7). ADC-mean (×10-3 mm2 /s) of G3 tumors (0.87 ± 0.43) was significantly lower than that of G1 (1.47 ± 0.63) and G2 (1.27 ± 0.63; P = 0.042). A weak significant negative correlation was observed between ADC and tumor grade (ADC-mean: r = -0.33, P = 0.02; ADC-min: r = -0.37, P = 0.01) and Ki-67 (ADC-mean: r = -0.31, P = 0.03; ADC-min: r = -0.39, P = 0.007). AUROC, sensitivity and specificity of ADC-mean/ADC-min/ER (measured at the early arterial phase) for differentiation of G3 versus G1-G2 were 0.80/0.76/0.67, 100%/50%/70%, and 68.4%/84.2%/66.6%, respectively. CONCLUSION: ADC is a promising marker for characterization of histopathologic grade of NETLM. These results should be confirmed in a prospective study. J. Magn. Reson. Imaging 2016;44:1432-1441.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/secundário , Tumores Neuroendócrinos/patologia , Tumores Neuroendócrinos/secundário , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Tumores Neuroendócrinos/diagnóstico por imagem , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
11.
J Magn Reson Imaging ; 43(4): 866-76, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26417669

RESUMO

PURPOSE: To quantify baseline relaxation rates R2* and R1 in the abdomen, their changes after respiratory challenges, and their reproducibility in healthy volunteers and patients with hepatocellular carcinoma (HCC) at 1.5T and 3.0T. MATERIALS AND METHODS: R2* measurements were acquired in the liver in 8 volunteers and 27 patients with 34 HCCs using multiecho T2* at baseline and after respiratory challenges with 100% oxygen (O2 ) and carbogen (CB = 95%O2 /5%CO2 ). R1 was measured at 1.5T in one volunteer and 21 patients with 23 HCCs. Test-retest coefficient of variation (CV) was assessed in 10 subjects. Intra- and interobserver variability of R2* and R1 measurements was assessed in 12 and 10 patients, respectively. Parameters for HCC, liver, and muscle were compared between baseline and after gas challenges. RESULTS: We observed that R2* and R1 imaging of HCCs with O2 and CB is feasible and reproducible (test-retest CV R2*<15%/R1 <5%; intra- and interobserver intraclass correlation coefficient R2*>0.88/R1 >0.7 and CV R2*<7%/R1 <3% at 1.5T). R2* measurements were observed to be less reproducible at 3.0T (CV<35%). There was a statistically significant decrease in R2* values in HCC before and after O2 (P = 0.02) and increase in R1 after O2 (P = 0.004). CB had no significant effect (P R2* = 0.47/R1 = 0.278). CONCLUSION: R2* measurements in HCC and liver parenchyma are more reproducible at 1.5T than at 3.0T, and with O2 than with CB challenge. We observed a decrease in R2* and an increase in R1 of HCCs from baseline in response to O2 challenge, as expected with increased tissue and blood oxygenation.


Assuntos
Dióxido de Carbono/química , Carcinoma Hepatocelular/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética , Oxigênio/química , Adulto , Idoso , Carcinoma Hepatocelular/patologia , Estudos de Viabilidade , Feminino , Voluntários Saudáveis , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Fígado/patologia , Neoplasias Hepáticas/patologia , Masculino , Pessoa de Meia-Idade , Músculos/diagnóstico por imagem , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Adulto Jovem
12.
J Magn Reson Imaging ; 43(5): 1064-72, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26469708

RESUMO

PURPOSE: To assess interplatform reproducibility of liver stiffness (LS) and spleen stiffness (SS) measured with magnetic resonance elastography (MRE) based on a 2D gradient echo (GRE) sequence. MATERIALS AND METHODS: This prospective Health Insurance Portability and Accountability Act (HIPAA)-compliant and Institutional Review Board (IRB)-approved study involved 12 subjects (five healthy volunteers and seven patients with liver disease). A multislice 2D-GRE-based MRE sequence was performed using two systems from different vendors (3.0T GE and 1.5T Siemens) on the same day. Two independent observers measured LS and SS on confidence maps. Bland-Altman analysis (with coefficient of reproducibility, CR), coefficient of variability (CV), and intraclass correlation (ICC) were used to analyze interplatform, intra- and interobserver variability. Human data were validated using a gelatin-based phantom. RESULTS: There was excellent reproducibility of phantom stiffness measurement (CV 4.4%). Mean LS values were 3.44-3.48 kPa and 3.62-3.63 kPa, and mean SS values were 7.54-7.91 kPa and 8.40-8.85 kPa at 3.0T and 1.5T for observers 1 and 2, respectively. The mean CVs between platforms were 9.2%-11.5% and 13.1%-14.4% for LS and SS, respectively, for observers 1 and 2. There was excellent interplatform reproducibility (ICC >0.88 and CR <36.2%) for both LS and SS, and excellent intra- and interobserver reproducibility (intraobserver: ICC >0.99, CV <2.1%, CR <6.6%; interobserver: ICC >0.97, CV and CR <16%). CONCLUSION: This study demonstrates that 2D-GRE MRE provides platform- and observer-independent LS and SS measurements.


Assuntos
Técnicas de Imagem por Elasticidade , Fígado/patologia , Imageamento por Ressonância Magnética , Baço/patologia , Adulto , Feminino , Voluntários Saudáveis , Hepatite C/diagnóstico por imagem , Hepatite C/patologia , Humanos , Hipertensão Portal , Fígado/diagnóstico por imagem , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Hepatopatias/patologia , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Imagens de Fantasmas , Estudos Prospectivos , Reprodutibilidade dos Testes , Baço/diagnóstico por imagem , Adulto Jovem
13.
J Magn Reson Imaging ; 44(4): 856-64, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-26919327

RESUMO

PURPOSE: To assess the correlation between intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) metrics in hepatocellular carcinoma (HCC) and liver parenchyma. MATERIALS AND METHODS: Twenty-five patients with HCC (M/F 23/2, mean age 58 years) underwent abdominal MRI at 1.5 or 3.0T, including IVIM-DWI (with 16 b-values) and DCE-MRI (3D FLASH sequence, mean temporal resolution of 2.3 sec). IVIM-DWI parameters (pseudodiffusion coefficient, D*, diffusion coefficient, D, and perfusion fraction, PF) were quantified in HCC lesions and liver parenchyma using a Bayesian fitting algorithm. DCE-MRI parameters (arterial flow, Fa , portal flow, Fp , total flow, Ft , mean transit time, MTT, distribution volume, DV, and arterial fraction, ART) were quantified using a dual-input single-compartment model. Correlations between IVIM-DWI and DCE-MRI parameters were assessed using a Spearman correlation test. RESULTS: Thirty-three HCC lesions (average size 5.0 ± 3.6 cm) were analyzed. D, D*, and PF were all significantly lower in HCC vs. liver (P < 0.05). Significantly higher Fa and ART and lower Fp were observed in HCC vs. liver (P < 0.001). Significant moderate to strong negative correlations were observed between ART and D* (r = -0.443, P = 0.028), ART and PF (r = -0.536, P = 0.006), ART and PFxD* (r = -0.655, P < 0.001), Fa and PF (r = 0.455, P = 0.023), and Fa and PFxD* (r = -0.475, P = 0.018) in liver parenchyma. There was no significant correlation between IVIM-DWI and DCE-MRI metrics in HCC lesions. CONCLUSION: IVIM-DWI and DCE-MRI provide nonredundant information in HCC, while they correlate in liver parenchyma. These findings may be secondary to predominant portal inflow in the liver and tortuous vasculature and tissue heterogeneity in tumors. J. MAGN. RESON. IMAGING 2016;44:856-864.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Adulto , Idoso , Algoritmos , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
MAGMA ; 29(1): 49-58, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26646522

RESUMO

OBJECTIVE: To quantify hepatocellular carcinoma (HCC) perfusion and flow with the fast exchange regime-allowed Shutter-Speed model (SSM) compared to the Tofts model (TM). MATERIALS AND METHODS: In this prospective study, 25 patients with HCC underwent DCE-MRI. ROIs were placed in liver parenchyma, portal vein, aorta and HCC lesions. Signal intensities were analyzed employing dual-input TM and SSM models. ART (arterial fraction), K (trans) (contrast agent transfer rate constant from plasma to extravascular extracellular space), ve (extravascular extracellular volume fraction), kep (contrast agent intravasation rate constant), and τi (mean intracellular water molecule lifetime) were compared between liver parenchyma and HCC, and ART, K (trans), v e and k ep were compared between models using Wilcoxon tests and limits of agreement. Test-retest reproducibility was assessed in 10 patients. RESULTS: ART and v e obtained with TM; ART, ve, ke and τi obtained with SSM were significantly different between liver parenchyma and HCC (p < 0.04). Parameters showed variable reproducibility (CV range 14.7-66.5% for both models). Liver K (trans) and ve; HCC ve and kep were significantly different when estimated with the two models (p < 0.03). CONCLUSION: Our results show differences when computed between the TM and the SSM. However, these differences are smaller than parameter reproducibilities and may be of limited clinical significance.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Fígado/patologia , Imageamento por Ressonância Magnética/métodos , Idoso , Algoritmos , Artérias/diagnóstico por imagem , Artérias/patologia , Humanos , Processamento de Imagem Assistida por Computador , Fígado/diagnóstico por imagem , Masculino , Perfusão , Estudos Prospectivos , Reprodutibilidade dos Testes , Água/química
15.
Radiology ; 275(1): 245-54, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25325326

RESUMO

PURPOSE: To develop a highly accelerated phase-contrast cardiac-gated volume flow measurement (four-dimensional [4D] flow) magnetic resonance (MR) imaging technique based on spiral sampling and dynamic compressed sensing and to compare this technique with established phase-contrast imaging techniques for the quantification of blood flow in abdominal vessels. MATERIALS AND METHODS: This single-center prospective study was compliant with HIPAA and approved by the institutional review board. Ten subjects (nine men, one woman; mean age, 51 years; age range, 30-70 years) were enrolled. Seven patients had liver disease. Written informed consent was obtained from all participants. Two 4D flow acquisitions were performed in each subject, one with use of Cartesian sampling with respiratory tracking and the other with use of spiral sampling and a breath hold. Cartesian two-dimensional (2D) cine phase-contrast images were also acquired in the portal vein. Two observers independently assessed vessel conspicuity on phase-contrast three-dimensional angiograms. Quantitative flow parameters were measured by two independent observers in major abdominal vessels. Intertechnique concordance was quantified by using Bland-Altman and logistic regression analyses. RESULTS: There was moderate to substantial agreement in vessel conspicuity between 4D flow acquisitions in arteries and veins (κ = 0.71 and 0.61, respectively, for observer 1; κ = 0.71 and 0.44 for observer 2), whereas more artifacts were observed with spiral 4D flow (κ = 0.30 and 0.20). Quantitative measurements in abdominal vessels showed good equivalence between spiral and Cartesian 4D flow techniques (lower bound of the 95% confidence interval: 63%, 77%, 60%, and 64% for flow, area, average velocity, and peak velocity, respectively). For portal venous flow, spiral 4D flow was in better agreement with 2D cine phase-contrast flow (95% limits of agreement: -8.8 and 9.3 mL/sec, respectively) than was Cartesian 4D flow (95% limits of agreement: -10.6 and 14.6 mL/sec). CONCLUSION: The combination of highly efficient spiral sampling with dynamic compressed sensing results in major acceleration for 4D flow MR imaging, which allows comprehensive assessment of abdominal vessel hemodynamics in a single breath hold.


Assuntos
Abdome/irrigação sanguínea , Aumento da Imagem/métodos , Adulto , Idoso , Algoritmos , Suspensão da Respiração , Meios de Contraste , Compressão de Dados , Feminino , Hemodinâmica , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional , Imageamento por Ressonância Magnética/métodos , Imagem Cinética por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Software
16.
J Magn Reson Imaging ; 41(1): 149-56, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24415565

RESUMO

PURPOSE: To evaluate short-term test-retest and interobserver reproducibility of IVIM (intravoxel incoherent motion) diffusion parameters and ADC (apparent diffusion coefficient) of hepatocellular carcinoma (HCC) and liver parenchyma at 3.0T. MATERIALS AND METHODS: In this prospective Institutional Review Board (IRB)-approved study, 11 patients were scanned twice using a free-breathing single-shot echo-planar-imaging, diffusion-weighted imaging (DWI) sequence using 4 b values (b = 0, 50, 500, 1000 s/mm(2)) and IVIM DWI using 16 b values (0-800 s/mm(2)) at 3.0T. IVIM parameters (D: true diffusion coefficient, D*: pseudodiffusion coefficient, PF: perfusion fraction) and ADC (using 4 b and 16 b) were calculated. Short-term test-retest and interobserver reproducibility of IVIM parameters and ADC were assessed by measuring correlation coefficient, coefficient of variation (CV), and Bland-Altman limits of agreements (BA-LA). RESULTS: Fifteen HCCs were assessed in 10 patients. Reproducibility of IVIM metrics in HCC was poor for D* and PF (mean CV 60.6% and 37.3%, BA-LA: -161.6% to 135.3% and -66.2% to 101.0%, for D* and PF, respectively), good for D and ADC (CV 19.7% and <16%, BA-LA -57.4% to 36.3% and -38.2 to 34.1%, for D and ADC, respectively). Interobserver reproducibility was on the same order of test-retest reproducibility except for PF in HCC. Reproducibility of diffusion parameters was better in liver parenchyma compared to HCC. CONCLUSION: Poor reproducibility of D*/PF and good reproducibility for D/ADC were observed in HCC and liver parenchyma. These findings may have implications for trials using DWI in HCC.


Assuntos
Carcinoma Hepatocelular/diagnóstico , Imagem de Difusão por Ressonância Magnética/métodos , Imagem Ecoplanar/métodos , Interpretação de Imagem Assistida por Computador/métodos , Neoplasias Hepáticas/diagnóstico , Movimento (Física) , Adulto , Idoso , Meios de Contraste , Gadolínio DTPA , Humanos , Aumento da Imagem , Fígado/patologia , Masculino , Meglumina/análogos & derivados , Pessoa de Meia-Idade , Variações Dependentes do Observador , Compostos Organometálicos , Estudos Prospectivos , Reprodutibilidade dos Testes
17.
AJR Am J Roentgenol ; 204(3): 510-8, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25714279

RESUMO

OBJECTIVE. The objective of our study was to evaluate the performance of a high-spatial-resolution 2D phase-contrast (PC) MRI technique accelerated with compressed sensing for portal vein (PV) and hepatic artery (HA) flow quantification in comparison with a standard PC MRI sequence. SUBJECTS AND METHODS. In this prospective study, two PC MRI sequences were compared, one with parallel imaging acceleration and low spatial resolution (generalized autocalibrating partial parallel acquisition [GRAPPA]) and one with compressed sensing acceleration and high spatial resolution (sparse). Seventy-six patients were assessed, including 37 patients with cirrhosis. Two observers evaluated PC image quality. Quantitative analyses yielded a mean velocity, flow, and vessel area for the PV and HA and an arterial fraction. The PC techniques were compared using the paired Wilcoxon test and Bland-Altman statistics. The sensitivity of the flow parameters to the severity of cirrhosis was also assessed. RESULTS. Vessel delineation was significantly improved using the PC sparse sequence (p < 0.034). For both in vitro and in vivo measurements, PC sparse yielded lower estimates for vessel area and flow, and larger differences between PC GRAPPA and PC sparse were observed in the HA. PV velocity and flow were significantly lower in patients with cirrhosis on both PC sparse (p < 0.001 and p = 0.042, respectively) and PC GRAPPA (p < 0.001 and p = 0.005, respectively). PV velocity correlated negatively with Child-Pugh class (r = -0.50, p < 0.001), whereas the arterial fraction measured with PC sparse was higher in patients with Child-Pugh class B or C disease than in those with Child-Pugh class A disease, with a trend toward significance (p = 0.055). CONCLUSION. A high-spatial-resolution highly accelerated compressed sensing technique (PC sparse) allows total hepatic blood flow measurements obtained in 1 breath-hold, provides improved delineation of the hepatic vessels compared with a standard PC MRI sequence (GRAPPA), and can potentially be used for the noninvasive assessment of liver cirrhosis.


Assuntos
Artéria Hepática/fisiologia , Cirrose Hepática/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Veia Porta/fisiologia , Fluxo Sanguíneo Regional , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
18.
Abdom Imaging ; 40(4): 803-9, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25294006

RESUMO

PURPOSE: To compare MR elastography (MRE) using a single and a dual driver excitation for the quantification of hepatic and splenic stiffness (HS and SS), and to investigate the performance of HS and SS measured with single or dual driver excitation for the detection of liver cirrhosis in subjects with liver disease. PATIENTS AND METHODS: This prospective HIPAA compliant and IRB approved study involved 49 subjects who underwent MRE at 3.0T, comparing three different acquisition methods (single driver on the liver, single driver on the spleen and dual driver acoustic excitation). A Mann-Whitney test was used to assess changes in stiffness values. Bland-Altman analysis was used to compare single and dual driver configurations for each organ. Performance for detection of liver cirrhosis was assessed using ROC analysis. Pearson correlation was used to estimate the dependence of HS and SS on spleen size. RESULTS: There were 40 noncirrhotic and 9 cirrhotic patients. There was good agreement between stiffness values measured with a single or a dual driver (Bland-Altman limits of agreement -14.3 % to 18.9 % and -18.1 % to 29.7 %, CV 6.4 % and 9.4 %, for HS and SS. respectively). HS and SS were higher in subjects with liver cirrhosis (p < 0.001), with excellent detection performance (AUROC range 0.87-0.93). SS correlated strongly with spleen size (r = 0.69, p < 0.001), while HS showed weak correlation (r = 0.38, p = 0.006). CONCLUSION: Using a dual acoustic driver configuration, hepatic and splenic stiffness can be simultaneously estimated with good concordance with single driver measurement.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Cirrose Hepática/patologia , Fígado/patologia , Imageamento por Ressonância Magnética/métodos , Baço/patologia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC , Reprodutibilidade dos Testes , Adulto Jovem
19.
Magn Reson Imaging ; 109: 227-237, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38508291

RESUMO

PURPOSE: Most T1 and T2 mapping take long acquisitions or needs specialized sequences not widely accessible on clinical scanners. An available solution is DESPOT1/T2 (Driven equilibrium single pulse observation of T1/T2). DESPOT1/T2 uses Spoiled gradient-echo (SPGR) and balanced Steady-State Free Precession (bSSFP) sequences, offering an accessible and reliable way for 3D accelerated T1/T2 mapping. However, bSSFP is prone to off-resonance artifacts, limiting the application of DESPOT2 in regions with high susceptibility contrasts, like the prostate. Our proposal, DESPO+, employs the full bSSFP and SPGR models with a dictionary-based method to reconstruct 3D T1/T2 maps in the prostate region without off-resonance banding. METHODS: DESPO+ modifies the bSSFP acquisition of the original variable flip angle DESPOT2. DESPO+ uses variable repetition and echo times, employing a dictionary-based method of the full bSSFP and SPGR models to reconstruct T1, T2, and Proton Density (PD) simultaneously. The proposed DESPO+ method underwent testing through simulations, T1/T2 phantoms, and on fourteen healthy subjects. RESULTS: The results reveal a significant reduction in T2 map banding artifacts compared to the original DESPOT2 method. DESPO+ approach reduced T2 errors by up to seven times compared to DESPOT2 in simulations and phantom experiments. We also synthesized in-vivo T1-weighted/T2-weighted images from the acquired maps using a spin-echo model to verify the map's quality when lacking a reference. For in-vivo imaging, the synthesized images closely resemble those from the clinical MRI protocol, reducing scan time by around 50% compared to traditional spin-echo T1-weighted/T2-weighted acquisitions. CONCLUSION: DESPO+ provides an off-resonance insensitive and clinically available solution, enabling high-resolution 3D T1/T2 mapping and synthesized T1-weighted/T2-weighted images for the entire prostate, all achieved within a short scan time of 3.6 min, similar to DESPOT1/T2.


Assuntos
Imageamento por Ressonância Magnética , Próstata , Masculino , Humanos , Próstata/diagnóstico por imagem , Imagens de Fantasmas , Imageamento por Ressonância Magnética/métodos , Artefatos , Voluntários Saudáveis
20.
Semin Liver Dis ; 33(2): 178-84, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23749674

RESUMO

Recognizing hepatocellular nodules that cannot be classified as typical for hepatocellular carcinoma, hepatocellular adenoma, or focal nodular hyperplasia is important, especially in a patient with high risk for hepatocellular carcinoma. The authors report a case of a 53-year-old man with chronic hepatitis B, who was referred to the hospital with a liver mass found on routine imaging follow-up. Abdominal ultrasound revealed a 2.4-cm hypoechoic lesion. Contrast computed tomography showed homogeneous arterial enhancement and mild hyperdensity on portal venous phase images. Due to the high risk for hepatocellular carcinoma, the patient underwent laparoscopic left lateral segmentectomy that revealed a 2.2-cm poorly defined red-brown lesion. The nodule was diagnosed as a hypervascular/telangiectatic hyperplastic hepatocellular nodule based on histopathologic findings and immunostaining profile with negative glutamine synthetase, diffuse positive CD34 highlighting hyperplastic endothelial cells along the telangiectatic sinusoids and dilated vascular channels, and CK7 and CK19 reactive normal bile ducts within the lesion.


Assuntos
Hiperplasia Nodular Focal do Fígado/diagnóstico , Hepatite B Crônica/diagnóstico , Telangiectasia/diagnóstico , Malformações Vasculares/diagnóstico , Biomarcadores/análise , Carcinoma Hepatocelular/diagnóstico , Carcinoma Hepatocelular/virologia , Diagnóstico Diferencial , Hiperplasia Nodular Focal do Fígado/metabolismo , Hiperplasia Nodular Focal do Fígado/cirurgia , Hepatectomia , Hepatite B Crônica/complicações , Humanos , Imuno-Histoquímica , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/virologia , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores , Valor Preditivo dos Testes , Telangiectasia/metabolismo , Telangiectasia/cirurgia , Ultrassonografia Doppler em Cores , Malformações Vasculares/metabolismo , Malformações Vasculares/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA