Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Radiology ; 294(3): 509-517, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31909697

RESUMO

Background Screening technologists may function as readers in breast cancer screening programs. In the Netherlands, they attend quality assurance sessions. The frequency and characteristics of additional breast cancers detected through these sessions have not been reported. Purpose To determine the frequency and characteristics of cancers detected through quality assurance sessions. Materials and Methods This secondary analysis of a prospective cohort included 466 647 screening mammograms obtained between January 1, 2009, and January 1, 2017. Mammograms were single read by certified screening technologists before being double read by two certified screening radiologists who were not blinded to the technologists' reading. The technologists and a coordinating screening radiologist regularly discussed mammograms that the technologists considered suspicious but that did not prompt recall at radiologist double reading. The coordinating radiologist decided whether secondary recall was indicated. During a 2-year follow-up, radiologic and pathologic outcome data for all recalled women were obtained. Characteristics of cancers detected at radiologist double reading and those detected through quality assurance sessions were compared by using χ2 and Fisher exact tests. Results A total of 14 142 women (mean age, 59 years ± 7.8 [standard deviation]; range, 49-75 years) were recalled (recall rate, 3.0% [14 142 of 466 647]): 14 057 after radiologist double reading and 85 by the coordinating radiologists after quality assurance sessions. This resulted in 3156 screening-detected cancers (6.8 cancers detected per 1000 screenings), of which 26 (0.8% of screening-detected cancers [26 of 3156]) were detected after secondary recall through quality assurance sessions. The latter comprised eight ductal carcinomas in situ (88% intermediate or high grade [seven of eight]) and 18 invasive cancers (14 T1a-c and four T2+ cancers, 89% Nottingham grade I or II [16 of 18]). No significant differences in tumor characteristics were found (P values ranging from .22 to .95). Sensitivity of quality assurance sessions for additional cancer detection was 52% (26 of 50; 95% confidence interval: 38%, 66%). Conclusion The role of quality assurance sessions in additional cancer detection is limited. Tumor characteristics did not differ significantly from those of cancers detected at radiologist double reading. © RSNA, 2020.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mama/diagnóstico por imagem , Detecção Precoce de Câncer , Mamografia , Idoso , Detecção Precoce de Câncer/métodos , Detecção Precoce de Câncer/normas , Feminino , Pessoal de Saúde , Humanos , Mamografia/métodos , Mamografia/normas , Pessoa de Meia-Idade , Países Baixos , Garantia da Qualidade dos Cuidados de Saúde , Radiologistas , Estudos Retrospectivos
2.
Obstet Gynecol ; 102(5 Pt 2): 1134-7, 2003 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-14607032

RESUMO

BACKGROUND: Incarcerated uterus is a rare condition with potentially serious complications that is often difficult to diagnose. This series shows the value of magnetic resonance imaging (MRI). CASES: Five pregnant women with incarcerated uterus are presented and the MRI findings compared with MRI in normal pregnancy. CONCLUSION: The use of MRI can be helpful in diagnosing this rare condition.


Assuntos
Imageamento por Ressonância Magnética , Complicações na Gravidez/diagnóstico , Neoplasias Uterinas/diagnóstico , Adolescente , Adulto , Feminino , Humanos , Gravidez , Útero/patologia
3.
Ned Tijdschr Geneeskd ; 154: A987, 2010.
Artigo em Holandês | MEDLINE | ID: mdl-20298626

RESUMO

A 76-year-old woman with no medical history apart from hypertension was admitted to the department of Internal Medicine with rectal bleeding. A few days later she complained of severe pain in her left leg. On physical examination the leg was swollen, shiny and extremely painful to the touch. Later she developed subcutaneous emphysema of the upper leg. A CT-scan revealed perforated sigmoid diverticulitis and extensive subcutaneous and intramuscular emphysema. During surgery, a double-barrelled colostomy was raised on the transverse colon. All subcutaneous areas with emphysema were drained. During a second operation, a Hartmann resection was performed, with a distal mucous fistula on the descending colon. A few days later she died as a result of septicaemia. Subcutaneous emphysema is a rare complication of perforated diverticulitis. A lack of prospective studies on diverticulitis hampers a rational approach to this common condition in daily practice.


Assuntos
Doença Diverticular do Colo/complicações , Enfisema Subcutâneo/etiologia , Idoso , Colo Transverso/cirurgia , Colostomia , Diagnóstico Diferencial , Doença Diverticular do Colo/diagnóstico , Doença Diverticular do Colo/cirurgia , Evolução Fatal , Feminino , Humanos , Fístula Intestinal/diagnóstico , Fístula Intestinal/etiologia , Fístula Intestinal/cirurgia , Enfisema Subcutâneo/diagnóstico , Enfisema Subcutâneo/cirurgia , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA