Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 167
Filtrar
1.
Radiat Phys Chem Oxf Engl 1993 ; 210: 111023, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37206369

RESUMO

Radiological staff, especially radiographers, work as front liners against the COVID-19 outbreak. This study aims to assess compliance with radiation protection and infection control practices during COVID-19 mobile radiography procedures. This cross-sectional study included 234 radiographers (females, 56%, n = 131; males, 44%, n = 103) who were asked to complete an online questionnaire consisting of demographic data, radiation protection and infection control practices during COVID-19 portable cases, and knowledge and awareness. After informed consent was completed, SPSS statistical software was used for the data analysis. The most common age group of participants ranged from 18 to 25 years old (30.3%, n = 71). Bachelor's degree holders were 74.4% (n = 174). Most radiographers (39.7%, n = 93) had a working experience of 1-5 years, followed by 27.8% (n = 65) with more than 16 years of experience. Most respondents (62.4%, n = 146) handled approximately 1-5 cases daily, the majority of them (56%, n = 131) stated affirmatively they had obtained special training to handle COVID-19, and when inquired if they had received any special allowances for handling COVID-19 suspected/confirmed cases most of them stated negative (73.9%, n = 173). Most participants stated that they always wear a TLD during portable cases (67.1%, n = 157) and a lead apron (51.7%, n = 121). Around 73% (n = 171) knew the latest information on COVID-19 and attended the COVID-19 awareness course. A significant association was found between the work experience of the radiographers and their responses to following the best practices (p = 0.018, α = 0.05). Radiographers who had COVID-19 training (µ = 48.78) tend to adhere more to best practices than those who have not (p = 0.04, α = 0.05). Further, respondents who handled more than 16/more COVID-19 suspected/confirmed cases followed the best practices more (µ = 50.38) than those who handled less (p = 0.04, α = 0.05). This study revealed detailed information on radiation protection and infection control practices during COVID-19 mobile radiography. It has been observed that the participants/radiographers have good knowledge and awareness of radiation protection and infection-control practices. The present results may be used to plan future requirements regarding resources and training to ensure patient safety.

2.
Environ Monit Assess ; 195(3): 382, 2023 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-36759352

RESUMO

This is the first attempt in the world to depict the vertical distribution of radionuclides in the soil samples along several heights (900 feet, 1550 feet, and 1650 feet) of Marayon Tong hill in the Chittagong Hill Tracts, Bandarban by HPGe gamma-ray spectrometry. The average activity concentrations of 232Th, 226Ra, and 40K were found to be 37.15 ± 3.76 Bqkg-1, 19.69 ± 2.15 Bqkg-1, and 347.82 ± 24.50 Bqkg-1, respectively, where in most cases, 232Th exceeded the world average value of 30 Bqkg-1. According to soil characterization, soils ranged from slightly acidic to moderately acidic, with low soluble salts. The radium equivalent activity, outdoor and indoor absorbed dose rate, external and internal hazard indices, external and internal effective dose rates, gamma level index, and excess lifetime cancer risk were evaluated and found to be below the recommended or world average values; but a measurable activity of 137Cs was found at soils collected from ground level and at an altitude of 1550 feet, which possibly arises from the nuclear fallout. The evaluation of cumulative radiation doses to the inhabitants via periodic measurement is recommended due to the elevated levels of 232Th.This pioneering work in mapping the vertical distribution of naturally occurring radioactive materials (NORMs) can be an essential factual baseline data for the scientific community that may be used to evaluate the variation in NORMs in the future, especially after the commissioning of the Rooppur Nuclear Power Plant in Bangladesh in 2024.


Assuntos
Monitoramento de Radiação , Rádio (Elemento) , Poluentes Radioativos do Solo , Monitoramento de Radiação/métodos , Poluentes Radioativos do Solo/análise , Bangladesh , Solo/química , Centrais Nucleares , Tório/análise , Rádio (Elemento)/análise , Radioisótopos de Potássio/análise , Espectrometria gama , Radiação de Fundo
3.
Cell Mol Biol Lett ; 27(1): 9, 2022 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-35093030

RESUMO

Bladder cancer is the fourth most common malignancy in males. It can present across the whole continuum of severity, from mild through well-differentiated disease to extremely malignant tumours with poor survival rates. As with other vital organ malignancies, proper clinical management involves accurate diagnosis and staging. Chemotherapy consisting of a cisplatin-based regimen is the mainstay in the management of muscle-invasive bladder cancers. Control via cisplatin-based chemotherapy is threatened by the development of chemoresistance. Intracellular cholesterol biosynthesis in bladder cancer cells is considered a contributory factor in determining the chemotherapy response. Farnesyl-diphosphate farnesyltransferase 1 (FDFT1), one of the main regulatory components in cholesterol biosynthesis, may play a role in determining sensitivity towards chemotherapy compounds in bladder cancer. FDFT1-associated molecular identification might serve as an alternative or appendage strategy for early prediction of potentially chemoresistant muscle-invasive bladder cancer tissues. This can be accomplished using Raman spectroscopy. Developments in the instrumentation have led to it becoming one of the most convenient forms of analysis, and there is a highly realistic chance that it will become an effective tool in the pathology lab. Chemosensitive bladder cancer tissues tend to have a higher lipid content, more protein genes and more cholesterol metabolites. These are believed to be associated with resistance towards bladder cancer chemotherapy. Herein, Raman peak assignments have been tabulated as an aid to indicating metabolic changes in bladder cancer tissues that are potentially correlated with FDFT1 expression.


Assuntos
Cisplatino , Neoplasias da Bexiga Urinária , Cisplatino/farmacologia , Cisplatino/uso terapêutico , Humanos , Masculino , Análise Espectral Raman , Neoplasias da Bexiga Urinária/tratamento farmacológico , Neoplasias da Bexiga Urinária/genética
4.
Radiat Environ Biophys ; 59(3): 523-537, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32462382

RESUMO

Accidents resulting in widespread dispersal of radioactive materials have given rise to a need for materials that are convenient in allowing individual dose assessment. The present study examines natural Dead Sea salt adopted as a model thermoluminescence dosimetry system. Samples were prepared in two different forms, loose-raw and loose-ground, subsequently exposed to 60Co gamma-rays, delivering doses in the range 2-10 Gy. Key thermoluminescence (TL) properties were examined, including glow curves, dose response, sensitivity, reproducibility and fading. Glow curves shapes were found to be independent of given dose, prominent TL peaks for the raw and ground samples appearing in the temperature ranges 361-385 ºC and 366-401 ºC, respectively. The deconvolution of glow curves has been undertaken using GlowFit, resulting in ten overlapping first-order kinetic glow peaks. For both sample forms, the integrated TL yield displays linearity of response with dose, the loose-raw salt showing some 2.5 × the sensitivity of the ground salt. The samples showed similar degrees of fading, with respective residual signals 28 days post-irradiation of 66% and 62% for the ground and raw forms respectively; conversely, confronted by light-induced fading the respective signal losses were 62% and 80%. The effective atomic number of the Dead Sea salt of 16.3 is comparable to that of TLD-200 (Zeff 16.3), suitable as an environmental radiation monitor in accident situations but requiring careful calibration in the reconstruction of soft tissue dose (soft tissue Zeff 7.2). Sample luminescence studies were carried out via Raman and Photoluminescence spectroscopy as well as X-ray diffraction, ionizing radiation dependent variation in lattice structure being found to influence TL response.


Assuntos
Radiometria/métodos , Sais , Radioisótopos de Cobalto , Raios gama , Luminescência , Medições Luminescentes , Oceanos e Mares , Temperatura
5.
J Radiol Prot ; 39(3): N8-N18, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31018196

RESUMO

Novel germanium (Ge)-doped silica glass fibres tailor-made in Malaysia are fast gaining recognition as potential media for thermoluminescence (TL) dosimetry, with active research ongoing into exploitation of their various beneficial characteristics. Investigation is made herein of the capability of these media for use in diagnostic imaging dosimetry, specifically at the radiation dose levels typically obtained in conduct of Computed Tomography (CT). As a first step within such efforts, there is need to investigate the performance of the fibres using tightly defined spectra, use being made of a Philips constant potential industrial x-ray facility, Model MG165, located at the Malaysian Nuclear Agency Secondary Standards Dosimetry Lab (SSDL). Standard radiation beam qualities (termed RQT) have been established for CT, in accord with IEC 61267: 2003 and IAEA Technical Reports Series No. 457: 2007. A calibrated ionisation chamber has also been utilised, forming a component part of the SSDL equipment. The fabricated fibres used in this study are 2.3 mol% flat fibre (FF) of dimensions 643 × 356 µm2 and 2.3 mol% cylindrical fibre (CF) of 481 µm diameter, while the commercial fibre used is 4 mol% with core diameter of 50 µm. The dopant concentrations are nominal preform values. The fibres have been irradiated to doses of 20, 30 and 40 milligray (mGy) for each of the beam qualities RQT 8, RQT 9 and RQT 10. For x-rays generated at constant potential values from 100 to 150 kV, a discernible energy-dependent response is seen, comparisons being made with that of lithium fluoride (LiF) thermoluminescence dosimeters (TLD-100). TL yield versus dose has also been investigated for x-ray doses from 2 to 40 mGy, all exhibiting linearity. Compared to TLD-100, greater sensitivity is observed for the fibres.


Assuntos
Germânio/química , Dosimetria Termoluminescente/instrumentação , Tomografia Computadorizada por Raios X , Calibragem , Desenho de Equipamento , Fluoretos/química , Compostos de Lítio/química , Malásia , Microscopia Eletrônica de Varredura , Fibras Ópticas , Doses de Radiação , Dióxido de Silício/química , Raios X
6.
J Radiol Prot ; 37(3): 761-779, 2017 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-28581438

RESUMO

The sensitivity of a novel silica-based fibre-form thermoluminescence dosimeter was tested off-site of a rare-earths processing plant, investigating the potential for obtaining baseline measurements of naturally occurring radioactive materials. The dosimeter, a Ge-doped collapsed photonic crystal fibre (PCFc) co-doped with B, was calibrated against commercially available thermoluminescent dosimetry (TLD) (TLD-200 and TLD-100) using a bremsstrahlung (tube-based) x-ray source. Eight sampling sites within 1 to 20 km of the perimeter of the rare-earth facility were identified, the TLDs (silica- as well as TLD-200 and TLD-100) in each case being buried within the soil at fixed depth, allowing measurements to be obtained, in this case for protracted periods of exposure of between two to eight months. The values of the dose were then compared against values projected on the basis of radioactivity measurements of the associated soils, obtained via high-purity germanium gamma-ray spectrometry. Accord was found in relative terms between the TL evaluations at each site and the associated spectroscopic results. Thus said, in absolute terms, the TL evaluated doses were typically less than those derived from gamma-ray spectroscopy, by ∼50% in the case of PCFc-Ge. Gamma spectrometry analysis typically provided an upper limit to the projected dose, and the Marinelli beaker contents were formed from sieving to provide a homogenous well-packed medium. However, with the radioactivity per unit mass typically greater for smaller particles, with preferential adsorption on the surface and the surface area per unit volume increasing with decrease in radius, this made for an elevated dose estimate. Prevailing concentrations of key naturally occurring radionuclides in soil, 226Ra, 232Th and 40K, were also determined, together with radiological dose evaluation. To date, the area under investigation, although including a rare-earth processing facility, gives no cause for concern from radiological impact. The current study reveals the suitability of the optical fibre based micro-dosimeter for all-weather monitoring of low-level environmental radioactivity.


Assuntos
Monitoramento Ambiental/instrumentação , Poluentes Radioativos do Solo/análise , Dosimetria Termoluminescente/instrumentação , Calibragem , Germânio/química , Fibras Ópticas , Dióxido de Silício , Fatores de Tempo
7.
J Radiol Prot ; 36(4): R96-R111, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27631675

RESUMO

Malaysia has initiated a range of pre-project activities in preparation for its planned nuclear power programme. Clearly one of the first steps is the selection of sites that are deemed suitable for the construction and operation of a nuclear power plant. Here we outline the Malaysian regulatory requirements for nuclear power plant site selection, emphasizing details of the selection procedures and site characteristics needed, with a clear focus on radiation safety and radiation protection in respect of the site surroundings. The Malaysia Atomic Energy Licensing Board (AELB) site selection guidelines are in accord with those provided in International Atomic Energy Agency (IAEA) and United Stated Nuclear Regulatory Commission (USNRC) documents. To enhance the suitability criteria during selection, as well as to assist in the final decision making process, possible assessments using the site selection characteristics and information are proposed.


Assuntos
Arquitetura de Instituições de Saúde/normas , Regulamentação Governamental , Centrais Nucleares/normas , Humanos , Malásia
8.
J Radiol Prot ; 36(2): 363-381, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27270958

RESUMO

After a release of radionuclides, accidental or otherwise, there will be an urgent need to identify members of the general public who have received a significant intake of radioactive material, sufficient to require medical treatment or further investigation. A large number of people could be contaminated in such an incident. For gamma-ray emitting radionuclides this screening could be carried out using gamma camera medical imaging systems, such as those that are present in many large UK hospital sites. By making a number of simple reversible changes such as removal of collimators, these cameras could be employed as useful additional screening instruments as well as an aid in contamination control. A study was carried out to investigate which systems were present in sufficient number to offer wide scale coverage of UK population centres. Nine gamma cameras (eight dual head and one single head) were assessed using point source and bottle mannequin (BOMAB) phantom measurements so that a mathematical model could be developed for use with the MCNPX Monte Carlo radiation transport code. The gamma camera models were assessed for practical seated and supine geometries to give calibration factors for a list of target radionuclides that could be released in a radiological incident. The minimum detectable activities (MDAs) that were achieved for a five minute measurement demonstrated that these systems are sufficiently sensitive to be used for screening of the general public and are comparable to other body monitoring facilities. While gamma cameras have on-board software that are designed for imaging and provide for a gamma-ray energy range suitable for radionuclides for diagnostic imaging (such as 99mTc), they are not as versatile as custom-built body monitoring systems.

9.
Appl Radiat Isot ; 210: 111371, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38815447

RESUMO

This work builds upon a prior study, examining the dosimetric utility of pencil lead and thin graphitic sheets, focusing upon the measurement of skin doses within the mammographic regime. In recognizing the near soft-tissue equivalence of graphite and the earlier-observed favourable thermoluminescence yield of thin sheets of graphite, this has led to present study of 50 µm thick graphite for parameters typical of external beam fractionated radiotherapy and skin dose evaluations. The graphite layers were annealed and then stacked to form an assembly of 0.5 mm nominal thickness. Using a 6 MV photon beam and delivering doses from 2- to 60 Gy, irradiations were conducted, the assembly first forming a superficial layer to a solid water phantom and subsequently underlying a 1.5 cm bolus, seeking to circumvent the build-up to electronic equilibrium for skin treatments. Investigations were made of several dosimetric properties arising from the thermoluminescence yield of the 50 µm thick graphite slabs, in particular proportionality and sensitivity to dose. The results show excellent sensitivity within the dose range of interest, the thermoluminescence response varying with increasing depth through the stacked graphite layers, obtaining a coefficient of determination of 90%. Acknowledging there to be considerable challenge in accurately matching skin thickness with dose, the graphite sheets have nevertheless shown considerable promise as dosimeters of skin, sensitive in determination of dose from the surface of the graphite through to sub-dermal depth thicknesses.


Assuntos
Grafite , Fótons , Pele , Grafite/química , Pele/efeitos da radiação , Humanos , Dosímetros de Radiação , Imagens de Fantasmas , Dosagem Radioterapêutica , Dosimetria Termoluminescente/métodos , Desenho de Equipamento
10.
Spectrochim Acta A Mol Biomol Spectrosc ; 308: 123743, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38113556

RESUMO

Trace and minor elements play crucial roles in a variety of biological processes, including amyloid fibrils formation. Mechanisms include activation or inhibition of enzymatic reactions, competition between elements and metal proteins for binding positions, also changes to the permeability of cellular membranes. These may influence carcinogenic processes, with trace and minor element concentrations in normal and amyloid tissues potentially aiding in cancer diagnosis and etiology. With the analytical capability of the spectroscopic technique X-ray fluorescence (XRF), this can be used to detect and quantify the presence of elements in amyloid characterization, two of the trace elements known to be associated with amyloid fibrils. In present work, involving samples from a total of 22 subjects, samples of normal and amyloid-containing tissues of heart, kidney, thyroid, and other tissue organs were obtained, analyzed via energy-dispersive X-ray fluorescence (EDXRF). The elemental distribution of potassium (K), calcium (Ca), arsenic (As), and iron (Fe) was examined in both normal and amyloidogenic tissues using perpetual thin slices. In amyloidogenic tissues the levels of K, Ca, and Fe were found to be less than in corresponding normal tissues. Moreover, the presence of As was only observed in amyloidogenic samples; in a few cases in which there was an absence of As, amyloid samples were found to contain Fe. Analysis of arsenic in amyloid plaques has previously been difficult, often producing contradictory results. Using the present EDXRF facility we could distinguish between amyloidogenic and normal samples, with potential correlations in respect of the presence or concentration of specific elements.


Assuntos
Arsênio , Oligoelementos , Humanos , Cálcio/análise , Espectrometria por Raios X/métodos , Oligoelementos/análise , Ferro/análise
11.
Appl Radiat Isot ; 210: 111372, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38810354

RESUMO

As is the case for most solid tumours, chemotherapy remains the backbone in the management of metastatic disease. However, the occurrence of chemotherapy resistance is a cause to worry, especially in bladder cancer. Extensive evidence indicates molecular changes in bladder cancer cells to be the underlying cause of chemotherapy resistance, including the reduced expression of farnesyl-diphosphate farnesyltransferase 1 (FDFT1) - a gene involved in cholesterol biosynthesis. This can likely be a hallmark in examining the resistance and sensitivity of chemotherapy drugs. This work performs spectroscopic analysis and metabolite characterization on resistant, sensitive, stable-disease and healthy bladder tissues. Raman spectroscopy has detected peaks at around 1003 cm-1 (squalene), 1178 cm-1 (cholesterol), 1258 cm-1 (cholesteryl ester), 1343 cm-1 (collagen), 1525 cm-1 (carotenoid), 1575 cm-1 (DNA bases) and 1608 cm-1 (cytosine). The peak parameters were examined, and statistical analysis was performed on the peak features, attaining significant differences between the sample groups. Small-angle x-ray scattering (SAXS) measurements observed the triglyceride peak together with 6th, 7th and 8th - order collagen peaks; peak parameters were also determined. Neutron activation analysis (NAA) detected seven trace elements. Carbon (Ca), magnesium (Mg), chlorine (Cl) and sodium (Na) have been found to have the greatest concentration in the sample groups, suggestive of a role as a biomarker for cisplatin resistance studies. Results from the present research are suggested to provide an important insight into understanding the development of drug resistance in bladder cancer, opening up the possibility of novel avenues for treatment through personalised interventions.


Assuntos
Cisplatino , Resistencia a Medicamentos Antineoplásicos , Análise Espectral Raman , Neoplasias da Bexiga Urinária , Humanos , Antineoplásicos/farmacologia , Antineoplásicos/uso terapêutico , Cisplatino/farmacologia , Cisplatino/uso terapêutico , Farnesiltranstransferase/metabolismo , Análise Espectral Raman/métodos , Neoplasias da Bexiga Urinária/tratamento farmacológico , Neoplasias da Bexiga Urinária/metabolismo , Neoplasias da Bexiga Urinária/patologia , Difração de Raios X , Farnesil-Difosfato Farnesiltransferase/metabolismo
13.
Appl Radiat Isot ; 202: 111071, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37871398

RESUMO

Due to the extended localized fluoroscopy, many radiographic exposures, and multiple procedures that might result in tissue reaction, patients and personnel received a significant radiation dose during interventional cardiology (IR) procedures. This study aims to calculate the radiation risk and assess patient and staff effective doses during IC procedures. Thirty-two patients underwent a Cath lab treatment in total. Ten Cath lab personnel, including six nurses, two cardiologists, and two X-ray technologists. Optical stimulating-luminescent dosimeters (OSL) (Al2O3:C) calibrated for this purpose were used to monitor both occupational and ambient doses. Using an automated OSL reader, these badges were scanned. The Air Kerma (mGy) and Kerma Area Products (KAP, mGy.cm2) have a mean and standard deviation (SD) of 371 ± 132 and 26052, respectively. The average personal dose equivalent (mSv) and its range for cardiologists, nurses and X ray technologists were 1.11 ± 0.21 (0.96-1.26), 0.84 ± 0.11 (0.68-1.16), and 0.68 ± 0.014 (0.12-0.13), respectively. The current study findings showed that the annual effective dose for cardiologists, nurses, and X-ray technologists was lesser than the yearly occupational dose limit of 20 mSv recommended by national and international guidelines. The patients' doses are comparable with some previously published studies and below the tissue reaction limits.


Assuntos
Exposição Ocupacional , Exposição à Radiação , Humanos , Doses de Radiação , Exposição Ocupacional/análise , Radiografia , Fluoroscopia/efeitos adversos , Fluoroscopia/métodos , Exposição à Radiação/efeitos adversos , Medição de Risco
14.
Appl Radiat Isot ; 199: 110920, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37419002

RESUMO

The present study continues research into the utilisation of carbonaceous media for medical radiation dosimetry, focusing on the effects of surface area-to-volume ratio and carbon content on structural interaction alterations and dosimetric properties in sheet- and bead-type graphitic materials (with the respective carbon content of ∼98 wt% and ∼90 wt%). Using 60Co gamma-rays and doses from 0.5 Gy to 20 Gy, the study has been made of the response of commercially available graphite in the form of 0.1 mm, 0.2 mm, 0.3 mm and 0.5 mm thick sheets, also of activated carbon beads. Confocal Raman and photoluminescence spectroscopy have been employed, examining radiation-induced structural interaction alterations. Dose-dependent variation in the Raman intensity ratio ID/IG relates to the varying dominance of defect generation and dose-driven defect annealing. Of the various thickness graphite sheets, the 0.1 mm thick medium possesses the greatest surface area-to-volume ratio. Perhaps unsurprisingly, it also exhibits the greatest thermoluminescence (TL) yield compared to that of the other carbonaceous sheet foils used herein. Moreover, the second greatest mass-normalised TL yield has been observed to be that of the porous beads, reflected in the greater defect density (ID/IG > 2) when compared to the other media, due in part to their inherent feature of large internal surface area. Considering the challenge posed in matching skin thickness with skin dose, the near tissue equivalent graphite sheets show particular promise as a skin dosimeter, sensitive as a function of depth.

15.
Appl Radiat Isot ; 193: 110626, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36640699

RESUMO

Breast cancer is a common malignancy for females (25% of female cancers) and also has low incidence in males. It was estimated that 1% of all breast malignancies occur in males with mortality rate about 20%, with annual increase in incidence. Risk factors include age, family history, exposure to ionizing radiation and high estrogen and low of androgens hormones level. Diagnosis and screening are challenging due to limiting effectiveness of breast cancer screening. Therefore, patients may expose to ionizing radiation that may contribute in breast cancer incidence in males. In literature, limited studies were published regarding radiation exposure for males during mammography. The objective of this research is to quantify patient doses during male mammogram and to estimate the projected radiogenic risk during the procedure. In total, 42 male patients were undergone mammogram for breast cancer diagnosis during two consecutive years. The mean and range of patient age (years) is 45 (23-80). The mean and standard deviation (SD) of the peak tube potential and tube current time product are 28.64 ± 2. and 149 ± 35.1, respectively. The mean, and range of patients' entrance surface air kerma (ESAK, mGy) per single breast procedure was 5.3 (0.47-27.5). Male patient's received comparable radiation dose per mammogram compared to female procedures. With increasing incidence of male breast cancer, proper guidelines are necessary for the mammographic procedure are necessary to reduce unnecessary radiation doses and radiogenic risk.


Assuntos
Neoplasias da Mama , Exposição à Radiação , Humanos , Feminino , Masculino , Doses de Radiação , Mamografia/métodos , Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Exposição à Radiação/análise
16.
Appl Radiat Isot ; 192: 110610, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36525913

RESUMO

In comparison to adults and paediatric are more sensitive to ionizing radiation exposure. Computed tomography (CT) is now the dominant source of medical radiologic tests for patients, accounting for more than 70% of total doses to the general public. Paediatric CT brain scans (with and without contrast) are routinely performed for a variety of clinical reasons. As a result, this parameter must be calculated in order to determine relative radiation risk. The goal of this study is to assess the radiation risk to children during CT brain diagnostic procedures. Three hundred fifty three child patients' radiation risk doses were assessed over the course of a year. The mean and ranged of the children's radiation doses were 40.6 ± 8.8 (27.8-45.8) CTDIvol (mGy) and 850 ± 230 (568.1-1126.4) DLP (mGy.cm) for the brain with contrast medium. For CT brain without contrast, the patients' doses were 40.9 ± 9.4 (14.27-64.07) CTDIvol (mGy), and 866.1 ± 289.3 (203.6-2484.9) DLP (mGy.cm). The characteristics related to the radiation dose were retrieved from the scan protocol generated by the CT system by the participating physicians after each procedure. Furthermore, optimizing the CT acquisition parameter is critical for increasing the benefit while lowering the procedure's radiogenic risk. The patients' radiation dose is comparable with the most previously published studies and international diagnostic reference levels (DRLs). Radiation dose optimization is recommended due to high sensitivity of the paediatric patients to ionizing radiation.


Assuntos
Angiografia por Tomografia Computadorizada , Tomografia Computadorizada por Raios X , Adulto , Humanos , Criança , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Cabeça , Encéfalo/diagnóstico por imagem , Valores de Referência
17.
Appl Radiat Isot ; 192: 110548, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36527854

RESUMO

Computed tomography coronary angiography (CTCA) has generated tremendous interest over the past 20 years by using multidetector computed tomography (MDCT) because of its high diagnostic accuracy and efficacy in assessing patients with coronary artery disease. This technique is related to high radiation doses, which has raised serious concerns in the literature. Effective dose (E, mSv) may be a single parameter meant to reflect the relative risk from radiation exposure. Therefore, it is necessary to calculate this quantity to point to relative radiation risk. The objectives of this study are to evaluate patients' exposure during diagnostic CCTA procedures and to estimate the risks. Seven hundred ninety patients were estimated during three successive years. The patient's exposure was estimated based on a CT device's delivered radiation dose (Siemens Somatom Sensation 64 (64-MDCT)). The participating physicians obtained the parameters relevant to the radiation dose from the scan protocol generated by the CT system after each CCTA study. The parameters included the volume CT dose index (CTDIvol, mGy) and dose length product (DLP, mGy × cm). The mean and range of CTDIvol (mGy) and DLP (mGy × cm) for three respective year was (2018):10.8 (1.14-77.7) and 2369.8 ± 1231.4 (290.4-6188.9), (2019): 13.82 (1.13-348.5), and 2180.5 (501.8-9534.5) and (2020) 10.9 (0.7-52.9) and 1877.3 (149.4-5011.1), respectively. Patients' effective doses were higher compared to previous studies. Therefore, the CT acquisition parameter optimization is vital to reduce the dose to its minimal value.


Assuntos
Angiografia por Tomografia Computadorizada , Tomografia Computadorizada por Raios X , Humanos , Angiografia Coronária/efeitos adversos , Angiografia Coronária/métodos , Doses de Radiação , Angiografia por Tomografia Computadorizada/efeitos adversos , Angiografia por Tomografia Computadorizada/métodos , Coração
18.
PLoS One ; 18(10): e0289113, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37856554

RESUMO

This work presents the first in-depth study of soil radioactivity in the mangrove forest of Bangladesh part of the Sundarbans. It used HPGe gamma-ray spectrometry to measure the amount of natural radioactivity in soil samples from Karamjal and Harbaria sites of the world's largest mangrove forest. The activity concentrations of most of the 226Ra (14±2 Bqkg-1 to 35±4 Bqkg-1) and 232Th (30±5 Bqkg-1 to 50±9 Bqkg-1) lie within the world average values, but the 40K concentration (370± 44 Bqkg-1 to 660±72 Bqkg-1) was found to have exceeded the world average value. The evaluation of radiological hazard parameters revealed that the outdoor absorbed dose rate (maximum 73.25 nGyh-1) and outdoor annual effective dose (maximum 0.09 mSvy-1) for most samples exceeded the corresponding world average values. The elevated concentration of 40K is mainly due to the salinity intrusion, usage of fertilizers and agricultural runoff, and migration of waste effluents along the riverbanks. Being the pioneering comprehensive research on the Bangladesh side of the Sundarbans, this study forms a baseline radioactivity for the Sundarbans before the commissioning of the Rooppur Nuclear Power Plant in Bangladesh.


Assuntos
Monitoramento de Radiação , Radioatividade , Rádio (Elemento) , Poluentes Radioativos do Solo , Doses de Radiação , Tório/análise , Radioisótopos de Potássio/análise , Solo , Áreas Alagadas , Poluentes Radioativos do Solo/análise
19.
Prog Biophys Mol Biol ; 182: 59-74, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37307955

RESUMO

Amyloidosis is a deleterious condition caused by abnormal amyloid fibril build-up in living tissues. To date, 42 proteins that are linked to amyloid fibrils have been discovered. Amyloid fibril structure variation can affect the severity, progression rate, or clinical symptoms of amyloidosis. Since amyloid fibril build-up is the primary pathological basis for various neurodegenerative illnesses, characterization of these deadly proteins, particularly utilising optical techniques have been a focus. Spectroscopy techniques provide significant non-invasive platforms for the investigation of the structure and conformation of amyloid fibrils, offering a wide spectrum of analyses ranging from nanometric to micrometric size scales. Even though this area of study has been intensively explored, there still remain aspects of amyloid fibrillization that are not fully known, a matter hindering progress in treating and curing amyloidosis. This review aims to provide recent updates and comprehensive information on optical techniques for metabolic and proteomic characterization of ß-pleated amyloid fibrils found in human tissue with thorough literature analysis of publications. Raman spectroscopy and SAXS are well established experimental methods for study of structural properties of biomaterials. With suitable models, they offer extended information for valid proteomic analysis under physiologically relevant conditions. This review points to evidence that despite limitations, these techniques are able to provide for the necessary output and proteomics indication in order to extrapolate the aetiology of amyloid fibrils for reliable diagnostic purposes. Our metabolic database may also contribute to elucidating the nature and function of the amyloid proteome in development and clearance of amyloid diseases.


Assuntos
Amiloide , Amiloidose , Humanos , Amiloide/química , Peptídeos beta-Amiloides/química , Análise Espectral Raman/métodos , Espalhamento a Baixo Ângulo , Difração de Raios X , Proteômica , Amiloidose/patologia
20.
Appl Radiat Isot ; 193: 110627, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36584412

RESUMO

Computed tomography is widely used for planar imaging. Previous studies showed that CR systems involve higher patient radiation doses compared to digital systems. Therefore, assessing the patient's dose and CR system performance is necessary to ensure that patients received minimal dose with the highest possible image quality. The study was performed at three medical diagnostic centers in Sudan: Medical Corps Hospital (MCH), Advance Diagnostic Center (ADC), and Advance Medical Center (AMC). The following tools were used in this study: Tape measure, Adhesive tape, 1.5 mm copper filtration (>10 × 10 cm), TO 20 threshold contrast test object, Resolution test object (e.g., Huttner 18), MI geometry test object or lead ruler, Contact mish, Piranha (semiconductor detector), Small lead or copper block (∼5 × 5 cm), and Steel ruler, to do a different type of tests (Dark Noise, Erasure cycle efficiency, Sensitivity Index calibration, Sensitivity Index consistency, Uniformity, Scaling errors, Blurring, Limiting spatial Resolution, Threshold, and Laser beam Function. Entrance surface air kerma (ESAK (mGy) was calculated from patient exposure parameters using DosCal software for three imaging modalities. A total of 199 patients were examined (112 chest X rays, 77 lumbar spine). The mean and standard deviation (sd) for patients ESAK (mGy) were 2.56 ± 0.1 mGy and 1.6 mGy for the Anteroposterior (AP) and lateral projections for the lumbar spine, respectively. The mean and sd for the patient's chest doses were 0.1 ± 0.01 for the chest X-ray procedures. The three medical diagnostic centers' CR system performance was evaluated and found that all of the three centers have good CR system functions. All the centers satisfy all the criteria of acceptable visual tests. CR's image quality and sensitivity were evaluated, and the CR image is good because it has good contrast and resolution. All the CR system available in the medical centers and upgraded from old X-ray systems to new systems, has been found to work well. The patient's doses were comparable for the chest X-ray procedures, while patients' doses from the lumbar spine showed variation up to 2 folds due to the variation in patients' weight and X-ray machine setting. Patients dose optimization is recommended to ensure the patients received a minimal dose while obtaining the diagnostic findings.


Assuntos
Cobre , Vértebras Lombares , Humanos , Doses de Radiação , Radiografia , Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA